View online or download pdf fadal VH5C three position collet air valve manual download and more fadal online manuals. Read the Fadal Miscellaneous user and admin manuals thoroughly and make sure the contents are completely understood in order to operate a machine efficiently and safely. They contain the detailed information necessary for safe operation, maintenance and correct servicing. If you have any doubt, call 1-800-342-3475.

itscnc
Download Presentation

Fadal VH5C Collet Air Valve Manual

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fadal VH5C Collet Air Valve VH5C Three Position Collet Air Valve Lever in Horizontal or Neutral position. Remove and adjust Collet. Lever in Down position. Loosen Collet—Relieves the tension on Collet allowing removal of part. Lever in Up position. Tighten Collet—Holds work in position. See back of sheet for additional information. August 2001 VH5C Three Position Collet Air Valve 1

  2. Fadal VH5C Collet Air Valve Detailed Information Several improvements have been made to the system. Internally, the ROT-0072 Collet Draw Tube and ROT-0074 End Cover have been redesigned to more positively allow airflow to evenly press upon the piston for opening and closing the collet. Externally, a new 3-position Air Switch is installed where the middle neutral position allows easier handling of the manual tightening. (See below). This 3-position Air Switch is arranged so that to release the Collet, the lever must be turned DOWN. To tighten the Collet, the lever must be turned UP. CENTER is the lever’s neutral position. The neutral position of the switch is connected to an EXHAUST air line, intended to carry exhausted air up out of the machining area to prevent any coolant contamination of the internal components of the Collet Closer system. All new VH5Cs being shipped will have these modifications to the Collet Closer system. In addition, units returned for service to the Collet Closer System will be updated upon request. Installation of a VH5C unit with these modifications is similar to previous procedures: 1) Connect fittings as show below in the diagram. COLLET air line connects directly to 80 PSI air supply at machine regulator. EXHAUST is the vent line and is tied to the main connector as shown. BRAKE is connected to the brake control solenoid and activated by M60 and M61. 2) Be certain that no moisture is allowed into the Collet Closer system. If no Dryer is installed on customer’s main air supply to prevent moisture contamination, then one must be installed on the machine. Fadal part number REG-0031 may be used for this purpose. 3) Collet operation procedure is as follows: a. Open the collet by lifting Air Switch lever DOWN. Insert workpiece into collet. b. Move Air Switch lever to CENTER (neutral) to relieve air pressure. c. Tighten ROT-0073 Adjustable Collar on back of Draw Tube. When rotational resistance is felt at workpiece as Collet tightens around it, loosen the Adjustable Collar 3/4 turn. d. Turn Air Switch lever UP to tighten Collet with air pressure. CAUTION: If step “c” is not followed, (i.e. loosening Collar 3/4 turn), Collet system may lock up from excessive loading. 2 VH5C Three Position Collet Air Valve August 2001

More Related