250 likes | 528 Views
Thank you to the following. TriAlpha:Alan Van DrieFor the data acquisition system Olga GornostaevaFor the 140 GHz InterferometerEusebio GarateFor countless hours of helpUC Irvine:William Heidbrink, and Roger McWilliams For advice and direction. Welcome to the Lab. The machine that we work on is the first machine built and used by TriAlpha.
E N D
1. Review of Irvine FRC Presentation Order
Erik Trask
Tommy Roche
Wayne Harris Topics Covered
Machine overview and density diagnostics
Magnetic mapping and Equilibrium comparison
Neutral Particle diagnostic and spectroscopy
3. Welcome to the Lab The machine that we work on is the first machine built and used by TriAlpha
4. Experimental Layout
5. Relevant physical parameters Peak density
~5 x 1013 cm-3
Max reversed magnetic field in plasma
250 Gauss
Temperatures
Ions ~ 2 eV
Electrons ~ 2 eV
Ion Rotational Energy
~ 25 eV
Wayne Harris will give more details
6. The nuts and bolts Vacuum system
Pumps and monitors
Energy Storage and Delivery
Capacitor Banks and Field Coils
Data Acquisition
Hardware and Software
Probes
e.g. B-dot loops, langmuir probes, interferometer, etc.
7. Pumping system is adequate Two pumps
VHS-6 and -10, backed with Welch 1397s
Large pump was cleaned within the year
Base pressure is ~ 10-6 Torr
Improved from ~10-5 Torr after cleaning
New Varian Multigauge controller
4 Convectorr gauges Atmosphere to 1 mTorr
1 Bayard-Alpert ionization gauge
Setpoint controller for interlocks
8. Energy storage parameters Upgraded Limiter bank from 900 volt max to 2700 volt max
2 x 6 array of 7700 uF capacitors
Diode crowbar
Shortened the rise time by lowering stray inductances
Improved Limiter field shape by changing transmission lines
Improved sightline access by spacing limiter straps
Old length was ~ 45 cm. Strap spacing was ~1 3 cm
New length is 60 cm with 5 cm spacing between straps
9. Limiter Coil Improvements Old configuration had both positive and negative transmission line connections at the south end of the set of limiter coils
New transmission lines are in a twisted pair topology
Path lengths are more balanced
Spacing between limiter coil straps is larger to allow for unobstructed sightlines from our access ports
10. Old Limiter Configuration As you can see, strap spacing is uneven
Sightlines from access ports were obstructed
11. New limiter looks nicer Precise 5 cm spacing between straps
Sightlines from all twelve access ports are clear!
12. and works better too! Less asymmetry is observed in our magnetic signals
Due to balanced path lengths for current flow
Lower impedance is evident in new configuration
Due to less stray inductance in the transmission lines
13. We can acquire many signals quickly 31 scopes are available for signal capture
27 BitScopes: 8 bit, 40 MHz peak sampling rate
Courtesy of Alan and others at TriAlpha
3 Tektronix scopes: 8 bit, up to 1 GS/s
1 ZTEC 2 channel scope: 12 bit, 200 MS/s
Acquisition software is Lab2000
Again, courtesy of Alan (Thanks!)
Analysis tools are written with IDL
Tommy Roche will give many examples
14. B-dots are a basic tool Four arrays
2 axial arrays
Sensitive to only Bz
2 radial arrays
3 orthogonal loops, measuring Br, B?, Bz
Calibrated in test coils
Software correction
orthogonalizes the data
2 dimensional recon-
struction: Tommy Roche
15. Rogowski: Plasma current monitor Coil is placed to measure currents induced in the plasma
Axial limits are the mirror coils ( 25 cm)
Radial limits are the flux coil (10cm) and limiter coil (37 cm)
Current waveforms depend strongly on mirror configuration
Three configurations of mirror coil
Mirror: Difficult to use and creates axially short plasmas
Open: Axially long plasmas
Cusp: Axially long plasmas and flat current profile More stable?
16. 4th generation Langmuir probes Triple probes earlier were focus of effort
Quiescent plasma are easily diagnosed
FRCs are NOT quiescent!
Inferred ne and Te signals were negative
Cause of discrepancies - large floating potential fluctuations? Swings of ~100 V in 10 microseconds have been measured.
Emphasis is now on floating double probes
This topology allows the probes to follow the floating potential more closely, reducing common mode pick up.
17. Double probes results more consistent Ion saturation currents are coupled across an isolation transformer
Can we use a double probe to find the temperature?
Common mode signals give a measurement of the floating potential
Capacitive coupling from primary to secondary of transformer
Is DC coupling better?
Can we also measure the high side of the bias voltage to find the temperature?
18. Two langmuir probe topologies
19. No single peak in radial Isat profile Peak densities of ~1013 cm-3
Assumes Te ~ 2 eV
Profiles are lumpy
More work needs to be done still
Swept double probe?
20. Interferometer results are puzzling 140 GHz system
Cutoff ne~2.514 cm-3
Langmuir probe data indicates densities below cutoff
For Te~2 eV
Interferometer data seems to show cutoff, even for just plasma and no reversal
21. Field reversal causes more cut off Interferometer signal looks cut off
Line density can only be trace back to 3.5 x 1012 cm-3
22. Why is interferometer cut off? Three main possibilities
Local densities could be higher than 2.5 x 1014 cm-3
Unlikely, given the Isat data
Poor sightlines (old limiter configuration) do not allow full signal measurement
Time changes in the line density could put the demodulated signal out of band
If the bandwidth is 10 MHz, the fastest change is 20? radians per microsecond
This corresponds to a density change of 6 x 1012 cm-3 per microsecond for a constant path length
23. Goal is measurement of LH wave propagation through the FRC
First antenna is built
Terminated-Folded Dipole
Loop antenna with small loop area
Resistive termination
Creates large E? and small Bz
RF probe built and in testing
Two dipoles, each 1 cm long
Orthogonal to each other
Will look at E? and Ez Lower hybrid experiment in progress
24. Must measure ne and Te better Future work will include:
Better Langmuir probe electronics
Measurement of the electron temperature
Resolution of interferometer problems
Lower hybrid wave measurements
25. Main systems functional Foundation of experiment is complete
Background density ~ 10-3 x ne
Data acquisition capabilities are sufficient
Magnetic field structures well known
Density diagnostics are coming on line