JRA3 STREGA - Introduction

JRA3 STREGA - Introduction. Geppo Cagnoli IGR – University of Glasgow ILIAS-GW Meeting, Orsay, 5 th -6 th Nov 2004. 10 9. 10 3. 10 6 [Hz]. 10 0. Interferometers. RF Cavities. Bars and Spheres. Overview on GW detection.

jadon
Download Presentation

JRA3 STREGA - Introduction

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. JRA3 STREGA - Introduction Geppo Cagnoli IGR – University of Glasgow ILIAS-GW Meeting, Orsay, 5th-6th Nov 2004

  2. 10 9 10 3 10 6 [Hz] 10 0 Interferometers RF Cavities Bars and Spheres Overview on GW detection • The expected strain of space is 10-22 Hz-1/2 or lower ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  3. Ultimate limits on GW detection All the detectors are mainly limited by thermal noise that causes fluctuations on position and shape of the test masses • Interferometers: thermal noise in mirrors and in suspension fibres • Bars/Spheres: thermal noise in the resonant elements • RF cavities: thermal noise in the cavity walls and in the e.m. field ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  4. STREGA Mission • Lower thermal noise 10 times • with respect to the • second generation detectors ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  5. 1ST GENERATION SHOULD REACH THE VIRGO CLUSTER AT 17MPc LIGO VIRGO 10 -19 • 1ST GENERATION • FOR IFOS • STEEL SUSPENSIONS (APART GEO600) • ROOM TEMPERATURE • FOR RESONATORS • ALUMINIUM CYLINDERS • 100mK < T < 4K AURIGA NAUTILUS 10 -20 GEO600 10 -21 10 -22 10 -23 10 -24 10 -25 LIGO SCIENTIFIC RUN 3 POSSIBLE DETECTION OF NS/NS MERGING WITHIN THE LOCAL GROUP DISTANCE < 1.8 MPc 10 100 1k 10k 1 Frequency [Hz] IFOS TH.NS BAND Detectors Generations h [ Hz –1/2 ] ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  6. LIGO VIRGO 10 -19 • 2ND GENERATION • FOR IFOS • SILICA SUSPENSIONS • HIGHER LASER POWER • ROOM TEMPERATURE • FOR RESONATORS • CuAl SPHERES • T < 100mK • BETTER READOUT • RF CAVITIES • 1ST DETECTORS AURIGA NAUTILUS 10 -20 PACO GEO600 10 -21 10 -22 MiniGRAIL AD. LIGO AD. VIRGO 10 -23 10 -24 10 -25 10 100 1k 10k 1 Frequency [Hz] Detectors Generations • 1ST GENERATION • FOR IFOS • STEEL SUSPENSIONS (APART GEO600) • ROOM TEMPERATURE • FOR RESONATORS • ALUMINIUM CYLINDERS • 100mK < T < 4K h [ Hz –1/2 ] ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  7. LIGO VIRGO 10 -19 • 3RD GENERATION • FOR IFOS • SILICON MIRRORS • SILICON SUSPENSIONS • HIGHER LASER POWER • BETTER COATINGS • LOW TEMPERATURE • FOR RESONATORS • CRISTALLINE MATERIALS • DOUBLE RESONATORS • T < 10mK • SQL • 2ND GENERATION • FOR IFOS • SILICA SUSPENSIONS • HIGHER LASER POWER • ROOM TEMPERATURE • FOR RESONATORS • CuAl SPHERES • T < 100mK • BETTER READOUT • RF CAVITIES • 1ST DETECTORS AURIGA NAUTILUS 10 -20 PACO GEO600 10 -21 10 -22 EGO MiniGRAIL AD. LIGO AD. VIRGO 10 -23 10 -24 DUAL Z = 1 10 -25 10 100 1k 10k 1 Frequency [Hz] Detectors Generations • 1ST GENERATION • FOR IFOS • STEEL SUSPENSIONS (APART GEO600) • ROOM TEMPERATURE • FOR RESONATORS • ALUMINIUM CYLINDERS • 100mK < T < 4K h [ Hz –1/2 ] ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  8. … coming back on Earth3 Objectives for STREGA • 1 Research on Materials Outcomes • - Selection or Development of the most suitable materials forMirrors, Suspensions and Resonant Masses • - Development of low losses Dielectric Coatings • - Investigation on Acoustic Emission caused by Cosmic Rays ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  9. … coming back on Earth3 Objectives for STREGA 2 Research on Cryogenics Outcomes - Development of a cryogenic system for the interferometers with a low mechanical noise - Design of a last stage suspension able to provide 1W of heat flow at ~5K - Development of a low noise ultra cryogenic system (~10mK) for resonant detectors ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  10. … coming back on Earth3 Objectives for STREGA 3 Research on Thermal Noise Outcomes - Development of facilities for the direct measurement of Thermo-elastic noise - Development of facilities for the direct measurement of Photo-elastic noise - Novel read-out configurations able to reduce the effect of thermal noise on the signal detected with resonant bars ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004

  11. Some Numbers 124 people of 25 different groups (subgroup of the Network) € 1794 per person per year STREGA web page: http://www.ego-gw.it/ILIAS-GW/ STREGA has the largest number of deliverables among the ILIAS activities (15 in the first 18 months) GOOD WORK !! ILIAS-GW Meeting, Orsay, 5th – 6th Nov 2004