An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hydrogen System – Piping and Instrumentation Diagram

  2. Hydrogen System P&ID Gas Panel Helium Store Venting Vac. Pumps Cryostat Heater/ Chiller Unit Hydrogen Bottle

  3. Line Types and Colour Coding Note: This scheme is based on operating the system with Hydrogen rather than Helium.

  4. Nomenclature • HA prefix used throughout to indicate Hydrogen System A • Pipelines • G or L prefix indicates whether line will contain gas or liquid during normal operation with cryo-cooler running. • Pipe size specified according to I.D. or DN standard.

  5. Nomenclature (2) • Valves • All uniquely numbered • PV – Pneumatic Valve • CV – Control Valve • HV – Hand Valve • BD – Bursting Disc • RV – Relief Valve • Sized by DN standard • Set pressure shown for relief valves

  6. Nomenclature (3) • Instrumentation • PG/VG – Pressure/Vacuum Gauge • LS – Level Sensor • TS – Temperature Sensor • HD – Hydrogen Detector • FM – Flow Meter • VP - Vacuum Pump

  7. Gas Panel and Hood Extraction Hood Fill/Purge Valves Hydride Bed Buffer Volume Absorber Relief Valves Cryostat Relief Valves

  8. Hydride Bed • Supplier: TREIBACHER INDUSTRIE AG • The nominal figures for the absorption temperature is -10°C and +20°C for the evolution temperature. • Heat Transfer Medium - Water / glycolMH • Weight: 120 kg • Tank Structure A hull with 7 inter-connected stainless-steel storage cylinders , each with internal coil for cooling/heating . • Dimensions Ø370 mm × L1500 mm (not including attachments), horizontal position • Tank Total Weight 260-280 kg • Operating Conditions: • Charging Gas Component Hydrogen of 99.99% purity • Charging Gas Pressure 1.2-1.7 bar abs • Hydrogen Charging Rate Max 70 NL/min • Discharging Gas Pressure 1.0-7.0 bar abs

  9. Fill/Purge Valves • Pneumatically actuated valves • Arrow indicates position on failure

  10. Valve Types • Ball Valves • Pneumatically actuated • Spring Return Actuators ensure valve returns to default position on failure • Control Valves • Pneumatically Actuated • Large range on throttling • Suitable for use with hydrogen

  11. Relief Valves • Tyco (AG Series 90) Relief Valves • Pilot valves – quick acting • 3% tolerance on set pressure • Closes at 95% of set pressure • Response time is <0.5s • BS&B Low Pressure Reverse Buckling Disc • ±5% tolerance on burst pressure • Vacuum/back pressure resistant • Hand Valves can be locked off as necessary

  12. Instrumentation • Temperature Sensors • Platinum Resistance • Fast response time (<0.5s) • Level Sensors • AMI Capacitance Level Transmitter • Useable with Hydrogen • Pressure and Vacuum Gauges • Leybold can supply capacitance vacuum gauges, which are safe for use with hydrogen. • Explosion proof pressure transducers available from Honeywell Temperature sensors Pressure Transducers Level Sensors

  13. Cryostat Cryocooler Helium Jacketing on Pipes Compressor Pressure Transducers Level Sensors Pre-cooling loops Electrical heating of base plate

  14. Vacuum System • 2 Elements • Purging Pump • for H2 system • Cryostat Vacuum

  15. Vacuum System TRIVAC D40B • Proposal received from Leybold based on combination of rotary vane and turbo-molecular pumps • TRIVAC D40B for hydrogen system purging pump (VP1) • Special Pumpset with active control suggested for cryostat vacuum (VP2) • D25BCS backing pump • Turbo-molecular TMP151C to achieve high vacuum (10-3 mbar) • Both pumps can be operated with purge gas (e.g. He) if pressure rises (indicating a leak) TRIVAC D25BCS TMP151C

  16. Venting • Hydrogen detectors in extraction hood, vent line and vacuum exhaust • 2 fans provide redundancy in venting from hood • Flame arrestors used throughout • Helium flow in vent line to dilute leaks Whessoe – Varec Flame Arrestor

  17. END