1 / 33

Cool Roofs in California’s Title 24 2005 Building Energy Efficiency Code

Cool Roofs in California’s Title 24 2005 Building Energy Efficiency Code. Elaine Hebert, Energy Efficiency Specialist California Energy Commission, Sacramento. What We Will Cover Today. How Cool Is a Cool Roof? How California’s Title 24 (Part 6 is Energy Code) Works

jag
Download Presentation

Cool Roofs in California’s Title 24 2005 Building Energy Efficiency Code

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cool Roofs in California’s Title 24 2005 Building Energy Efficiency Code Elaine Hebert, Energy Efficiency Specialist California Energy Commission, Sacramento

  2. What We Will Cover Today • How Cool Is a Cool Roof? • How California’s Title 24 (Part 6 is Energy Code) Works • Title 24 Cool Roof regulations • Contact Information/Resources

  3. How Cool is a Cool Roof? (1) Sacramento, CA July 12, 2000 89 ºF, about noon, with local delta breeze BUR topped with aggregate 159 °F BUR topped with capsheet 158 °F EPDM single-ply 173 °F Courtesy Dan Varvais, Applied Polymer Systems

  4. How Cool is a Cool Roof? (2) Sacramento, CA July 12, 2000 89 ºF noon delta breeze Cool single-ply 121 °F Cool coating over BUR 108 °F Courtesy Dan Varvais, Applied Polymer Systems

  5. Cool Roofs and Energy • Cooler roof surfaces can save 15% of electricity needed to cool a building • This is important because we still have an electricity crisis. • Not quite enough supply to meet demand and have mandated reserve • Transmission lines – aging, inadequate capacity

  6. Adequate electricity supplies help prevent blackouts in California (this blackout in the Midwest equaled about $6B in damage)

  7. Through Energy Efficiency Measures, California Keeps Per Person Use of Electricity Steady While Rest of US Goes Up

  8. Title 24, Part 6, California’s Energy Code: How It Works (1) • Sets an energy budget for residential and nonresidential buildings • New buildings and additions/alterations (alterations can include re-roofing) • Budget is in kBtu/square foot/year • Budget varies by climate zone • 16 climate zones in California

  9. California’s 16 Climate Zones www.energy.ca.gov/maps/climate_zone_map.html Climate Zone 1, coastal, foggy most of year Climate Zone 16 – mountains, snows in winter, less than 80°F in summer Many inland climate zones – mild winters, hot dry summers (population increasing most, air conditioning needs increasing)

  10. Efficiency of Lighting Windows, doors, skylights Water heating systems Space heating and cooling systems Nonresidential Roofs (as of Oct. 2005) Insulation levels in walls, floors, and ceilings/attics/roofs Tightness of air ducts Allowed square footage of windows, doors, and skylights And more ... Title 24, Part 6: How It Works (2)Regulates the Following:

  11. Title 24, Part 6: How It Works (3) How to Meet the Energy Budget • Design the building or addition/alteration with appropriate energy efficiency features • Submit documentation to bldg. dept. with permit application • Construct the building/addition/alteration with those features Building Inspectors are responsible for confirming that the installed energy features match the features in the paperwork you submitted

  12. Meeting the Energy Budget:Design and build a building … …using items from previous slide that comprise: Prescriptive Measures OR Performance Method Mandatory Measures (for energy efficiency) AND Provide documentation to bldg dept with bldg permit application

  13. “Prescriptive” means - - • Title 24 provides a list of the minimum efficiencies of some energy features. The list is like a prescription for how to construct a building to meet the energy budget. • Follow the ‘prescription’ exactly to construct the building and it automatically complies with Title 24 – no calculations or computer needed

  14. “Performance” means - - • Model how the entire building will perform energy-wise using approved computer program – Allows flexibility -can trade off among energy efficiency measures – Energy budget for your (modeled) building is established by a similar modeled building (“standard building”) having all mandatory and prescriptive measures Buy software yourself, or hire a Title 24 consultant - see www.cabec.org for trained Calif. energy consultants; most have the software

  15. Cool Roofs Are a Prescriptive Measure for Nonresidential Buildings (Cool roofs are NOT mandatory) WHICH MEANS • if you use the prescriptive compliance method, you must install a cool roof (or do an allowed tradeoff among building envelope components only) OR • if you use performance compliance, you can install a cool roof or not, but a cool roof helps set the energy budget for your proposed project

  16. What is a (Prescriptive) Cool Roof under California’s Title 24 Energy Standards? Roof materialmust • Be rated through Cool Roof Rating Council (Title 24, Part 1, §10-113) • Be properly labeled (Title 24, Part 1, §10-113) • Have reflectance ≥ 0.70 and emittance ≥ 0.75 (or if emittance is lower, need higher reflectance)[Part 6, §118(i)1 and 2] • For coatings liquid-applied in the field, meet performance requirements [Part 6, §118(i)3 & Table 118-C]

  17. What Are Reflectance and Emittance? • Reflectance – straightforward – sun’s energy (heat) bouncing off roof surface • Emittance – not ALL energy bounces off; some is absorbed. Absorbed energy is given off – emitted – at different rates by different materials. “Emittance” is a measure of how quickly or efficiently the absorbed energy is given off. • Important because slowly emitted heat has time to penetrate downward into the building - - undesirable in most Calif. climate zones; increases air conditioning

  18. Title 24 (Prescriptive) Cool Roofs Apply to - - • Conditioned space (heated or cooled) • Low slopes (≤ 2:12) • Nonresidential buildings only, Occupancy Groups A, B, E, F, H, M, S, and U (next slide) EXCLUDES • Occupancy “I”- hospitals, prisons, mental institutions, other institutions • hotels/motels • refrigerated warehouses

  19. Occupancy Groups (from CBC/UBC) • A = Assembly – theaters, churches, restaurants, etc • B = Businesses – office buildings, colleges/univers. • E = Educational facilities (12th grade & under) • F = Factories, low and moderate hazard • H = High hazard facilities • M = Mercantile; sale of merchandise • S = Storage, low and moderate hazard • U = Utility – garages, towers, agric. buildings, etc Expanded list on page 8 of www.energy.ca.gov/2005publications/CEC-400-2005-053/CEC-400-2005-053.PDF

  20. Cool Roofs Are Only Optional(NOT prescriptive, NOT mandatory) for - - • Hotels and motels • ALL residential buildings (including houses and high-rise apartments/condos) • Unconditioned buildings • Refrigerated warehouses, other spaces held under 55°F, and spaces held over 90°F • Buildings cooled by evaporative coolers/swamp coolers • Roofs with slopes over 2:12

  21. Take Note Qualifying historic buildings (per Title 24, Part 8) are exempted from Title 24, Part 6 energy standards.

  22. Cool Roofs 2005 -Nonresidential Re-roofing • Still prescriptive • If >50% or >2,000 sf of low-sloped roof, whichever is less, is being replaced, recovered, or recoated, cool roof “requirements” kick in [§ 149(b)1B] • Install a cool roof OR • Install a noncool roof plus roof insulation • This is how a garden roof or BIPV* roof can be installed when re-roofing • Coming soon: easy calculator for how much insulation *BIPV = Building-integrated photovoltaics (solar electric pv modules become the roof)

  23. Reroofing Existing Unconditioned Warehouse Containing Conditioned Office Space - Cool Roof?? Consider two cases: 1. Conditioned space’s ceiling is lower than warehouse roof

  24. Unconditioned warehouse containing conditioned space (see the air ducts!) Energy Commission considers this building unconditioned, so no cool roof rules are triggered

  25. Case 1 – Reroofing unconditioned warehouse containing conditioned office – walls of office do not reach warehouse roof • No cool roof requirements are triggered!

  26. Case 2 – Reroofing unconditioned warehouse containing conditioned office – walls of office reach up to warehouse roof • (Sorry, no photo yet) • Cool Roof requirements apply OVER THE CONDITIONED SPACE(S) ONLY not over the entire warehouse roof

  27. TAKE NOTE! • Energy Star is a different program (Federal not state) • An Energy Star roof does not automatically qualify as a cool roof in California • Cool Roof Rating Council’s rated product directory has over 650 roof materials – some comply with Title 24 and some don’t

  28. Excerpt from CRRC Rated Product Directory (www.coolroofs.org)

  29. NOTE: “Partly” Cool Roofs • Roofing materials not meeting the FULL 0.70 reflectance/0.75 emittance Title 24 levels can get “partial” energy credit for some building types when using computer performance modeling and overall envelope prescriptive compliance Materials NOT rated through CRRC are assigned a default value in Title 24 for reflectance – it is LOW – so you must meet the energy budget using other energy-efficient features

  30. Help Is on the Way Energy Commission has started a collaborative for training on cool roof regulations for • Roofing Contractors • Building departments • And eventually, architects/specifiers, building owners, consultants

  31. Resources • Title 24 Website – www.energy.ca.gov/title24 (Title 24 Energy Standards and support documents) • Title 24 Energy Hotline - 1-800-772-3300 (within CA), 916-654-5106 (outside CA), title24@energy.state.ca.us • Title 24 Office – 916/654-4064 • Elaine Hebert – 916/654-4800, ehebert@energy.state.ca.us • Approved energy compliance software: • MicroPas (residential),www.micropas.com • EnergyPro (res & nonres), www.energysoft.com

  32. Resources • Cool Roof Rating Council - www.coolroofs.org, (866) 465-2523 • CABEC (Calif. Assoc. of Building Energy Consultants) - www.cabec.org, (866) 360-4002 • Title 24 Energy Information Videos (free) - www.energyvideos.com • Coming soon: cool roof website, insulation calculator, shortened form for cool roof reroofing permits, training materials for roofing contractors & other parties, 2008 Standards

  33. Thank you!