RKP111A00x

RKP111A00x. Régulateur compact Pour la régulation d’une température constante. RKP111A - Caractéristiques :. ALIMENTATION : 230Vac. SIGNAL DE SORTIE : 3 POINTS. RELAIS DE SORTIE : LIBRE DE POTENTIEL :24...250Vac / 20…300Vdc. DIMENSIONS REDUITES. SONDE A COMPOSANT Pt 1000.

jamal
Download Presentation

RKP111A00x

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RKP111A00x Régulateur compact Pour la régulation d’une température constante

  2. RKP111A - Caractéristiques : • ALIMENTATION : 230Vac • SIGNAL DE SORTIE : 3 POINTS • RELAIS DE SORTIE : LIBRE DE POTENTIEL :24...250Vac / 20…300Vdc • DIMENSIONS REDUITES • SONDE A COMPOSANT Pt 1000 • INDICE DE PROTECTION : IP54 • VISUALISATION DE L’ETAT DES SORTIES ET DE L’ALIMENTATION PAR VOYANT

  3. RKP111A - Les réglages : PLAGE DE REGLAGE : 60…120°C OU 0…60°C BANDE PROPORTIONNELLE Xp : ±10K ou ±20K REGLAGE DE LA CONSIGNE DE TEMPERATURE : ENTRE 0°C & 60°C OU ENTRE 60°C & 120°C ZONE NEUTRE Nz : ±1,5K ou ±3,0K TEMPS DE COURSE DU MOTEUR : ≥30s OU ≥60s

  4. RKP111A – Raccordement électrique : RACCORDEMENT DE LA SONDE RACCORDEMENT DU MOTEUR ALIMENTATION 230Vac

  5. RKP111A – Les voyants : VOYANT DU SIGNAL DE SORTIE : VOYANT DE L’ALIMENTATION LE VOYANT S’ALLUME EN ROUGE : ORDRE D’OUVERTURE LE VOYANT S’ALLUME EN VERT : ORDRE DE FERMETURE

  6. RKP111A - Les montages : MONTAGE EN APPLIQUE • POUR LA REGULATION DE TEMPERATURE CONSTANTE : • DE DEPART DE CIRCUIT DE CHAUFFAGE • D’EAU CHAUDE SANITAIRE • D’ECHANGEUR DE CHALEUR

  7. RKP111A - Les montages : MONTAGE EN DOIGT DE GANT • POUR LA REGULATION DE TEMPERATURE CONSTANTE : • DE DEPART DE CIRCUIT DE CHAUFFAGE • D’EAU CHAUDE SANITAIRE • D’ECHANGEUR DE CHALEUR

  8. RKP111A - Les montages : MONTAGE DANS GAINE D’AIR • POUR LA REGULATION DE TEMPERATURE CONSTANTE: • D’UNE BATTERIE A EAU

  9. RKP111A – Accouplement avec un thermostat : LES RKP111A PEUVENT ETRE ACCOUPLES AVEC LES THERMOSTATS RAM34x : LES THERMOSTAT A REARMEMENT AUTOMATIQUE (TW) : RAM342.001M : PLAGE 15…95°C LES THERMOSTATS A REARMEMENT MANUEL (TB) : RAM343.0/3345M : PLAGE 15…60°CRAM343.0/3346M : PLAGE 50…130°C