1 / 11

2013 東莞塘廈內銷廠 康展二電廠 報告

新金寶集團 New Kinpo Value. 2013 東莞塘廈內銷廠 康展二電廠 報告. 報告人 : 夏兵榮 2013 年 12 月 07 日. 康展 二電廠 KPI. 康展二電廠 業績 ---12 月份預估目標 :0.05e. ※ 說明 : 11 月業績需求 0.04e , 實際達成 0.06e. 康展 201 3 年客戶 PPM. 一 、 電源不良8 臺 占總不良100% : 1 ) GP9002-000GT HS1&HS2 與機殼打火*3 臺 ,

Download Presentation

2013 東莞塘廈內銷廠 康展二電廠 報告

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 新金寶集團 New Kinpo Value 2013東莞塘廈內銷廠 康展二電廠 報告 報告人:夏兵榮 2013年12月07日

  2. 康展 二電廠KPI

  3. 康展二電廠 業績---12月份預估目標:0.05e ※說明 : 11月業績需求0.04e ,實際達成0.06e

  4. 康展2013年客戶PPM 一、電源不良8臺 占總不良100%: 1) GP9002-000GT HS1&HS2 與機殼打火*3臺, 對策:1.在機殼接合處及輸出線材口塗 EPOXY膠,導入新灌膠工法,並在上蓋增加絕緣膠,RD已 發EC(P1ECO-1307130);2.每工令抽3~5PCS做浸水 1m 試驗(IP67 規格要求) 2) GPD003-000GT *5PCS D1 SH*3臺 客戶操作不當 AC 輸入與DC 輸出接反.對策:在LABEL上增加備注AC 輸入與DC 輸出標示; 4) 端子臺破損*1臺 客戶組裝造成 建議客戶調整扭力; 5) U1 NG*1臺(廠商:品佳)不良送廠商分析;

  5. 康展2013年OQA PPM 說明:1>作業問題*1件 GP9002 漏鎖上蓋螺絲*1件 對策:1>宣導所有鎖螺絲人員.按先後順序作業后必須自檢.用螺絲盤計數,使用完後如螺絲盤內有多或少要立即向領班反應.外觀總檢重點確認單體螺絲是否有漏鎖.

  6. 康展2013年Yield Rate 說明: 11月份Yield rate未達標,分析與改善如報告

  7. 2013年11月 Yield Rate 改善計劃

  8. 二電庫存週天數趨勢圖 ※未達成原因 DTD模塊金額8,726KNTD,影響83天;LED照明金額5,526KNTD,影響52天;康碩展影響3.6天

  9. 康展二電廠Conversion cost ※說明:達標

  10. 康展廠 離職率 ※說明:10月份二電作業員離職1人(舒莉霞)====已補

  11. 敬請指教

More Related