GLARING WEAKNESS: . Jacob Slifer + Andrea John Arch 373. Summer 2013. Grondzik. VISUAL COMFORT AND THE PERCEPTION OF GLARE IN THE DAVID LETTERMAN COMMUNICATIONS AND MEDIA BUILDING LOBBY . The David letterman building. HYPOTHESIS.

jamuna
Download Presentation

Jacob Slifer + Andrea John Arch 373. Summer 2013. Grondzik

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GLARING WEAKNESS: Jacob Slifer + Andrea John Arch 373. Summer 2013. Grondzik VISUAL COMFORT AND THE PERCEPTION OF GLARE IN THE DAVID LETTERMAN COMMUNICATIONS AND MEDIA BUILDING LOBBY

  2. The David letterman building HYPOTHESIS Between the hours of 9am to 3pm, we expect glare to be perceived by the visitors of the David Letterman Building’s lobby due to the prominent amount of unshaded glazing of the east facade. More specifically, the morning hours of 9am to 11 am will have a greater perception of glare by visitors due to position of the sun. We propose that glare can be readily perceived by visitors to the lobby of the David Letterman Communications and Media Building, such that at least half of the visitors will concede some degree of visual discomfort while using the lobby. Plan View

  3. MethoDology Our approach to data collection for this case study was divided into two parts; the first being personal interviews of occupants of the David Letterman Building lobby (seeinterview sample in Results section), and the second being measured readings of luminance taken with a luminance meter. Luminance values around the hours of 10am and 2pm were recorded with the use of a Minolta Luminance Meter Model LS-100 Grid pattern created by authors of this study. Each point denotes a location in which luminance was measured.

  4. The Survey • How often do you use the lobby in the David Letterman Communication and Media Building? • Do you ever notice glare while you are using the lobby? • If so, does this determine whether you continue to use the lobby at the time? • If so, where in the lobby do you perceive glare to be the “worst,” or most likely to occur? • If so, when would you say the glare is worst during the day? • Would you prefer for the lighting in the lobby to be brighter? Dimmer? Remain the same? • Do you ever have difficulty reading from your books in the lobby? From your phone? Computer? • Do you have any other comments you would care to share about the lighting or glare in the lobby?

  5. Luminance Maps

  6. Luminance Map For Vertical Surfaces

  7. Lessons Learned Graphical representation of the seating in the David Letterman Building lobby, and where glare is perceived to be worst, or most likely to occur Our hypothesis proved correct, if by a very thin margin, as 50% of interviewees stated they did indeed perceive glare resulting in discomfort. Based on both the measurements and the interview responses we can assert that the vast amount of glazing on the eastern wall is what causes this. There are no shading devices attempting to mitigate direct sun light, and all of the seating is located in close proximity to the windows. Considering that very few visitors said the glare would cause them to avoid the lobby, it may be possible that the lobby is the only convenient location for them to sit when they are waiting before, between, or after classes. Our only question lies in whether these luminance values would have affected how the David Letterman Building was designed had it’s architect foreseen the discomfort half of its visitors perceive.

  8. Lessons Learned Based on these tables shown, 100 to 200 cd/m^2 is the luminance range deemed desirable for “moderate” tasks. However, as the luminance maps show, nearly all of the surfaces in the lobby are above this range in the 10am time slot. The luminance range preferred for wall surfaces is 25-100cd/m^2, but only the higher surfaces and the southern surfaces fall within this range. Task luminance, with a range of 100 to 500 cd/m^2, is much more forgiving. However, it is worth noting that the majority of horizontal surfaces measured were of fabric-based materials. It is likely that more reflective surfaces such as paper would result in higher values.