280 likes | 426 Views
COMFEN 4.0: IECC 2009 Baseline Energy Performance. W. S. E. N. ► Boston Baseline Energy Performance by Wall Orientation (40% Window to Wall Ratio). COMFEN 4.0: IECC 2009 Baseline Energy Performance. W. S. E. N.
E N D
COMFEN 4.0: IECC 2009 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (40% Window to Wall Ratio)
COMFEN 4.0: IECC 2009 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (40% Window to Wall Ratio)
COMFEN 4.0: IECC 2009 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (40% Window to Wall Ratio)
COMFEN 4.0: IECC 2009 Baseline Energy Performance W S E N 43.71 kBtu/ft2-yr Base Case 33.72 kBtu/ft2-yr -22.86% 43.05 kBtu/ft2-yr -1.51% 40.08 kBtu/ft2-yr -8.32% West Wall South Wall East Wall North Wall ► Boston Baseline Energy Performance by Wall Orientation (40% Window to Wall Ratio)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (30% Window to Wall Ratio)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (30% Window to Wall Ratio)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (30% Window to Wall Ratio)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N 40.20 kBtu/ft2-yr Base Case 32.12 kBtu/ft2-yr -20.11% 39.85 kBtu/ft2-yr -0.87% 38.01 kBtu/ft2-yr -5.45% West Wall South Wall East Wall North Wall ► Boston Baseline Energy Performance by Wall Orientation (30% Window to Wall Ratio)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (40% WWR with Daylighting Controls)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (40% WWR with Daylighting Controls)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N ► Boston Baseline Energy Performance by Wall Orientation (40% WWR with Daylighting Controls)
COMFEN 4.0: IECC 2012 Baseline Energy Performance W S E N 41.25 kBtu/ft2-yr Base Case 30.69 kBtu/ft2-yr -25.60% 41.11 kBtu/ft2-yr -0.35% 40.08 kBtu/ft2-yr -2.86% West Wall South Wall East Wall North Wall ► Boston Baseline Energy Performance by Wall Orientation (40% WWR with Daylighting Controls)
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance W W W W ► Boston Baseline Energy Performance - Prescriptive Code Comparison for West Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance W W W W ► Boston Baseline Energy Performance - Prescriptive Code Comparison for West Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance W W W W ► Boston Baseline Energy Performance - Prescriptive Code Comparison for West Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance W W W W 43.71 kBtu/ft2-yr Base Case 40.20 kBtu/ft2-yr -8.03% 41.25 kBtu/ft2-yr -5.62% 31.55 kBtu/ft2-yr -27.83% IECC 200940% WWR IECC 2012 30% WWR IECC 2012 40% WWR w/ Daylighting Controls IECC 2009/2012 Opaque Wall ► Boston Baseline Energy Performance - Prescriptive Code Comparison for West Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance S S S S ► Boston Baseline Energy Performance - Prescriptive Code Comparison for South Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance S S S S ► Boston Baseline Energy Performance - Prescriptive Code Comparison for South Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance S S S S ► Boston Baseline Energy Performance - Prescriptive Code Comparison for South Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance S S S S 33.72 kBtu/ft2-yr Base Case 32.12 kBtu/ft2-yr -4.75% 30.69 kBtu/ft2-yr -8.97% 30.83 kBtu/ft2-yr -8.55% IECC 200940% WWR IECC 2012 30% WWR IECC 2012 40% WWR w/ Daylighting Controls IECC 2009/2012 Opaque Wall ► Boston Baseline Energy Performance - Prescriptive Code Comparison for South Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance E E E E ► Boston Baseline Energy Performance - Prescriptive Code Comparison for East Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance E E E E ► Boston Baseline Energy Performance - Prescriptive Code Comparison for East Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance E E E E ► Boston Baseline Energy Performance - Prescriptive Code Comparison for East Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance E E E E 43.05 kBtu/ft2-yr Base Case 39.85 kBtu/ft2-yr -7.43% 41.11 kBtu/ft2-yr -4.51% 31.49 kBtu/ft2-yr -26.86% IECC 200940% WWR IECC 2012 30% WWR IECC 2012 40% WWR w/ Daylighting Controls IECC 2009/2012 Opaque Wall ► Boston Baseline Energy Performance - Prescriptive Code Comparison for East Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance N N N N ► Boston Baseline Energy Performance - Prescriptive Code Comparison for North Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance N N N N ► Boston Baseline Energy Performance - Prescriptive Code Comparison for North Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance N N N N ► Boston Baseline Energy Performance - Prescriptive Code Comparison for North Wall
COMFEN 4.0: IECC 2009 vs. 2012 Baseline Energy Performance N N N N 40.08 kBtu/ft2-yr Base Case 38.01 kBtu/ft2-yr -5.15% 40.08 kBtu/ft2-yr -0.00% 31.69 kBtu/ft2-yr -20.94% IECC 200940% WWR IECC 2012 30% WWR IECC 2012 40% WWR w/ Daylighting Controls IECC 2009/2012 Opaque Wall ► Boston Baseline Energy Performance - Prescriptive Code Comparison for North Wall