STRESS ECG AND STRESS ECHOCARDIOGRAPHY

STRESS ECG AND STRESS ECHOCARDIOGRAPHY. Giuseppe Biondi Zoccai Division of Cardiology , University of Turin , Turin , Italy Meta-analysis and Evidence-based medicine Training in Cardiology (METCARDIO), Ospedaletti , Italy. LEARNING GOALS. Scope of the problem Stress ECG

jasmine
Download Presentation

STRESS ECG AND STRESS ECHOCARDIOGRAPHY

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STRESS ECG AND STRESS ECHOCARDIOGRAPHY Giuseppe Biondi Zoccai DivisionofCardiology, UniversityofTurin, Turin, Italy Meta-analysis and Evidence-based medicine Training in Cardiology(METCARDIO), Ospedaletti, Italy

  2. LEARNING GOALS • Scope of the problem • Stress ECG • Stress echocardiography • Reconciling the evidence

  3. LEARNING GOALS • Scope of the problem • Stress ECG • Stress echocardiography • Reconciling the evidence

  4. FINDING AN APPROPRIATE DIAGNOSTIC LEVEL

  5. FINDING AN APPROPRIATE PROGNOSTIC LEVEL

  6. DIAGNOSTIC AND PROGNOSTIC WORK-UP OF SUSPECTED CORONARY HEART DISEASE • Clinical history • Physical examination • Resting ECG • Resting echocardiography • Stress ECG • Stress echocardiography • Stress nuclear scan • Coronary CT • Coronary angiography • ….

  7. EFFECTIVE RADIATION DOSES Picano, Am J Med 2003

  8. CORONARY STEAL PHENOMENON Picano, Circ 1998

  9. CORONARY STEAL PHENOMENON Picano, Circ 1998

  10. THREE STATES OF THE SODIUM CHANNEL AND THE NORMAL SODIUM CURRENT (INa) 0 Late Na+ SodiumCurrent Na+ Na+ Peak Activated Resting Closed Inactivated out Na+ in Na+ [Na] 140 mM Na+ Na+ Na+ Na+ ~ 10mM Ca++ Ca++ in Ca++ Ca++ Na+ Ca++ Ca++ out Na+/Ca++ Exchanger Na+ Ca++

  11. Excess Calcium: • Electrical instability • Contractile dysfunction • ECG changes ISCHEMIA INDUCED EFFECTS ON LATE INa AND INTRACELLULAR CALCIUM 0 SodiumCurrent Late Na+ Impaired Inactivation Peak Na+ Na+ out Na+ Na+ Na+ Ca++ Na+ Na+ in Na+ Na+ Na+ Na+ Ca++ Ca++ Ca++ Ca++ Ca++ Ca++ Ca++ Ca++ in Ca++ Ca++ Na+ Ca++ Ca++ Ca++ Ca++ out Na+/Ca++ Exchanger Na+ Ca++

  12. THE ISCHEMIC CASCADE

  13. LEARNING GOALS • Scope of the problem • Stress ECG • Stress echocardiography • Reconciling the evidence

  14. TREADMILL STRESS TEST

  15. KEY ACCESSORY

  16. EQUIPMENT FOR STRESS TESTING • Treadmill or bicycle or steps • ECG machine • Blood pressure cuff • Computer is a ‘nice to have’ • ACLS certification • Defibrillation/intubation cart • Exit strategy • Good help* (it takes two to test)

  17. PROTOCOLS

  18. TYPICAL BRUCE OR RAMP STRESS RAMP WORK WORK TIME TIME

  19. WHY USE A BIKE ERGOMETER? 1. Accurate measurement of POWER. 2. Ramping protocols allow for assessment of physiologic function across all work levels. 3. Independent of patient’s weight. 4. Less danger of fall and injury to patient. 5. Easier to take accurate B/P at high work rates. 6. Patient can stop at anytime. 7. Holding handle bars does not effect test (Holding treadmill handrails can significantly effect results). 8. Fits into smaller space and is portable. 9. Patients with knee or hip problems tend to perform better and report being more comfortable on the bike.

  20. WHY USE A BIKE ERGOMETER? 10. Bike ramp protocols are designed to last 6-10 minutes, resulting in less fatigue (yet peak work is maximized). 11. HR, Work, and VO2 (Cardiac Output) are linearly related. Bike ramp protocols produce linear increases in Work, thereby mimicking the expected physiologic response in health and disease. 12. Determination of the Anaerobic Threshold (AT) by the most popular methods (V-slope and VE/VO2 nadir) were developed and proven through the use of bike ramp protocols. To use another method means to lose AT detection accuracy. 13. Bike ramp protocols are used by many of the leading clinical and research cardiopulmonary exercise testing labs (UCLA, Duke, Mayo, Stanford, Bowman-Gray, Johns Hopkins, UAB, Temple to name a few). Recently, treadmills capable of performing ramp protocols have been developed.

  21. MY VIEW: TREADMILL IS BEST

  22. INDICATIONS TO STRESS TEST • Diagnosis of coronary artery disease • Risk-stratification of coronary artery disease • Risk-stratification in cardiac valve disease • Appraisal of rate response • Appraisal of pressure response to stress • Appraisal of functional capacity

  23. INFORMATION OBTAINED FROM EXERCISE STRESS BUT NOT AVAILABLE WITH PHARMACOLOGICAL TEST • Exercise duration/tolerance • Reproducibility of symptoms with activity • Heart rate response to exercise • Blood Pressure response • Detection of stress induced arrhythmias • Assess control of angina with medical therapy • Prognosis

  24. KEY ASPECTS • Exercise duration and work-load (minutes, METs, Watts) • Maximum blood pressure • Maximum heart rate (given that predicted for age) • Rate-pressure product • Baseline ECG • ST-segment changes • T-wave changes • Q waves • Duke treadmill score • Heart rate recovery

  25. ABNORMAL RESPONSE TO STRESS TESTING • Heart rate fails to rise above 120 or unable to attain target heart rate of 85% of max • Blood pressure shows a drop in systolic • Patient physically unable to complete test • Marked hypertension, >260/115 • Chest Pain and/or unusual shortness of breath

  26. NORMAL RESPONSE OF ECG TO STRESS TESTING ECG Changes • QRS complex decreases in size • J point depresses, resulting in up sloping of ST segment • ST segment returns to baseline by 80 milliseconds • PR segment may down slope – thus baseline is defined as PQ junction • R amplitude may decrease at rates that go above 130 • T wave decreases

  27. ABNORMAL RESPONSE OF ECG TO STRESS TESTING ECG Changes • Horizontal or down sloping ST segments • ST segment depressed or elevated • ST segment does not return to baseline by 80 milliseconds • U or T wave inversion • Dysrhythmias – rate dependent blocks above first degree, WPW appears, Atrial fib/flutter, multiform and/or increasing PVC’s, V-tach occurs

  28. ECG CHANGES

  29. ECG CHANGES

  30. RISK

  31. CRITERIA DIAGNOSTIC FOR ISCHEMIA • Horizontal or down sloping ST segment with depression of 1 or greater mm. • Horizontal, up or down sloping ST segment with elevation of 1 or greater mm. • Up sloping ST depression greater than 1.5 mm at J+80 msec.

  32. CRITERIA DIAGNOSTIC FOR ISCHEMIA • Horizontal or down sloping ST segment with depression of 1 or greater mm. • Horizontal, up or down sloping ST segment with elevation of 1 or greater mm. • Up sloping ST depression greater than 1.5 mm at J+80 msec.

  33. CRITERIA SUGGESTIVE FOR ISCHEMIA • Horizontal or down sloping ST segment with depression greater than 0.5mm but <1 mm. • Up sloping ST depression between 0.7 and 1.5mm at J+80 msec. • Chest pain or fall in Blood pressure or persistent HTN in recovery or new S3 or murmur at peak exercise. (<1 mm)

  34. SYMPTOM-SIGN LIMITED TESTING ENDPOINTS – WHEN TO STOP! Dyspnea, fatigue, chest pain Systolic blood pressure drop ECG--ST changes, arrhythmias Physician Assessment Borg Scale (17 or greater)

  35. PREDICTED MAXIMUM HEART RATE

  36. WHAT IS A MET? Metabolic Equivalent Term 1 MET = "Basal" aerobic oxygen consumption to stay alive = 3.5 ml O2 /Kg/min Actually differs with thyroid status, post exercise, obesity, disease states But by convention just divide ml O2/Kg/min by 3.5

  37. MAJOR DETERMINANTS OF MYOCARDIAL OXYGEN CONSUMPTION Picano, Circ 1998

  38. PROGNOSTIC ROLE OF METs Myers et al, New Engl J Med 2002

  39. PREDICTING CARDIAC DEATH Marcus et al, Chest 1995

  40. DUKE TREADMILL SCORE

  41. BAYES THEOREM If P(B) ≠ ), then P(A/B) = “ P(B/A)P(A) “ P(B/A)P(A) + P(B/not A)P (not A)

  42. CONTINUOUS OF RISK

  43. TYPICAL REPORT Treadmill stress test stopped at the end of the 3rd standard Bruce stage for fatigue (max BP 200/100 mm Hg, max HR 140 bpm, RPP 28,000). No symptoms. No arrhythmias. No abnormalities in the baseline ECG. In the 2nd stage development of ST depression, which becomes diagnostic in the 3rd stage (max 1.5 mm in V5 at the peak), with quick recovery after the stress. Duke treadmill score: 1 (<-11 high risk; >4 low risk). Heart rate recovery: 10 (valore di riferimento >12). Positive stress test for myocardial ischemia at mid-to-high work-load.

  44. GUIDELINES Gibbons et al, Circ 2002

  45. GUIDELINES: RECOMMENDATIONS Gibbons et al, Circ 2002

  46. GUIDELINES: RECOMMENDATIONS Gibbons et al, Circ 2002

  47. STRESS EKG ISNOT A SLAM DUNK • 5/10,000 result in serious cardiovascular event • 1/10,000 result in death • Results are based on Bayes Theorem • Requires proper selection, preparation, and execution • Not the GOLD standard

  48. LEARNING GOALS • Scope of the problem • Stress ECG • Stress echocardiography • Reconciling the evidence

  49. STRESS ECHOCARDIOGRAPHY

  50. BASIC PRINCIPLE OF STRESS ECHO