1 / 35

MED009: Carbon release study from BN

This study focuses on the production of intense 11C ion beams for carbon-based hadron therapy. It explores target developments, dose delivery localization, range uncertainties, and PET-imaging for dose verification. The study also examines the production of 11C ion beams and target materials such as boron nitride (BN).

Download Presentation

MED009: Carbon release study from BN

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MED009: Carbon release studyfrom BN S. Stegemann July – October 2018

  2. Outline 11C based hadron therapy Production of intense 11C ionbeams Target developments MED009

  3. External beam radiation therapy Particle beam: Photon, proton, carbon

  4. More localized dose delivery Dose is spread out over healthy tissue as well B R A G G P E A K Depends on incident energy of protons X-ray Protoncarbon E. Sterpin. MEDICIS-Promed Summer school. CNAO, Pavia. (2017)

  5. Why11C based hadron therapy?

  6. Range uncertainties due to… Image conversion to stopping powers • Uncertainties • Image noise • Tissue assignment? (Fat, bone, muscle, skin…) • Tissue composition • Conversion of a known composition to stopping powers • Total uncertainty of a few % ! Map of stoppingpowers Hounsfield Units (photon attenuation) Breathing of the patient From Lomax Day 0 Day 35 Anatomical changes throughout the treatment fractions E. Sterpin. Treatment planning optimization and validation‘ MEDICIS-Promed Summer School, Pavia (2017)

  7. PET-imaging for dose verification 12C 12C 11C 1 1 Dose Dose 20 Fluence [particle/cm2] as % of primary keV T1/2 = 20.4 min 0 z [cm] Dose [Gy] Dose [Gy] Fluence [particle/cm2] as % of primary Depth in H2O 10-4 10-4 11C -20 107 107 20 β+activity β+activity Events Events 0 z [cm] 103 103 0 0 x [cm] 40 x [cm] 40 Depth in H2O -20 FLUKA simulation of dose and β+ activity distributions with a 12C and 11C primary beam, courtesy of R. Augusto (*) R.S. Augusto et al., NIM B 376 (2016) 374-378 11C beam combines therapy with on-line PET-imagingOn-line dose verification, treatment validation

  8. Production of intense 11C ion beams

  9. 11C based hadron therapy facility (MEDICIS-Promed) ISOL methodIsotope Separation On-Line 11CO1+ Beam cooler p Electron Beam Ion Source 11C4/6+ Injection into Medical Accelerator

  10. Target developments

  11. Target material Boron nitride (BN) 11B(p,n)11C 14N(p,α)11C Calculated in-target production yield 11B(p,n)11C 14N(p,α)11C

  12. Isotope release Diffusion: (Arrhenius eq.) D: Diffusion coefficient μ : Diffusion time λ : Decay constant G:Grain size Control microstructure to enhance release properties Proton +/- 8V 500 A Pulsed Protons 1. Production (Nuclear Reactions) +/- 9 V Ion Source 1000 A 2. Diffusion 3. Effusion 4. Ionization J.-P. Ramos. EMIS Xlll, CERN, Geneva, 2018.

  13. Target processing • 100 °C/min heating rate • 1700 °C final sintering-temperature • Sintering-pressure 25 MPa at1700 °C for 5 min • ρbulk= 1.3(1) g cm-3 • Φtot = 0.40(1) total porosity • Φopen= 0.21(2) open porosity Spark Plasma Sintering • High pulsed DC currents into powder compact • High heating/cooling rates • Minimizes grain growth at low T • Maintaining of micro,- (nano-) structures

  14. Heat management Equilibrium calculation P = 10-6mbar YProd= I·Nt·

  15. High-temperaturemeasurements Modest dissociation kinetics, even at 1500 °C CO2(HBO?) • 2BN = 2B + N2(g) • Low dissociation rate! • BN can ce applied with 1500 °C! N2 N

  16. Increasing [C]  Increasing O2 uptake • But: No conclusive information from MS data • C enhances O2 uptake, but CO could not be measured

  17. MED009

  18. MED009 Sc. Detector • Produce 11C at MEDICIS • Retrieve active target material • Measure 11C activity • Fast & short heat treatment • Measure remaining 11C activity BN target T1/2(11C) = 20.4 min  minimize timing! Sc. Detector Release efficiencystudy

  19. Furnace @ 1500 ֯C Detector Tube containing active target O2 leak

  20. Data analysis progressing Preliminary

  21. Acknowledgements Thierry Stora Joao-Pedro Ramos JochenBallof ErmannoBarbero Bernard Crepieux Nhat-Tan Vuong MEDICIS Team ISOLDE Team Joao Guilherme Martins Correia Juliana Schell Thomas Cocolios OleksiiPoleshchuk

  22. Thank you. Questions, comments? This research project has been supported by a Marie Skłodowska-Curie Innovative Training Network Fellowship of the European Commission’s Horizon 2020 Programme under contract number 642889 MEDICIS-PROMED.

  23. Backup

  24. Sintering atom flux [J-1s-1]D: diffusion coefficient [m2s-1]C: concentration [m-3] densification rate (e.g. lattice diffusion) grain growth rate Densification&Grain growth P: Porosity G : Grain size Limit grain growth, since Note the time dependence! • Mechanism: Diffusion • Sintering:

  25. G : grain size r : pore size Sintered BN powder pellet

  26. Combining therapy with on-line PET-imaging 11C beam for treatment

  27. γ p E. Sterpin. MEDICIS-Promed Summer school. CNAO, Pavia. (2017)

  28. Ionization • Essential process for the beam purification with magnets • Surface ion source • Laser ion source • Plasma ion source • Electron Cyclotron Resonance (ECR) ion source • Short ionization time • No hot metal surfaces (retention)

  29. Treatment plan assumes that images acquired are a faithful representation of the anatomy during the entire course of treatment • Not true: • Patient not positioned all the time the same way • Breathing motion not stable • Position of targets and the organs at risk may change one relative to another (organ filling) • Morphology of the patient may change (weight loss, tumor shrinkage)

More Related