1 / 17

New Flowcell – How Easy?

New Flowcell – How Easy?. New Flowcell – How Easy?. SenCell. SenCell. Small, robust, easy to handle Stepless variable spacing. SenCell - Specifications. Working electrode GC 2mm Reference electrode Salt Bridge - blue ISAAC - green HYREF – black. Sensitivity – wall jet.

jerome
Download Presentation

New Flowcell – How Easy?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Flowcell – How Easy?

  2. New Flowcell – How Easy?

  3. SenCell

  4. SenCell Small, robust, easy to handle Stepless variable spacing

  5. SenCell - Specifications • Working electrode GC 2mm • Reference electrode • Salt Bridge - blue • ISAAC - green • HYREF – black

  6. Sensitivity – wall jet • Flow cell design • A. thin-layer • B. wall-jet • C. porous flow-through

  7. Cotrell Equation • ECD  Cottrell equation • ilim= 1.47 n F (Fm)1/3 (DA/b)2/3C ilim= C spacer thickness A= WE area A b = spacer thickness C = concentration

  8. Variable spacing – more signal • Stepless variable spacing • Smaller spacing • Higher signal

  9. Spacing

  10. Sensitivity – more signal100um vs 12 um spacing

  11. Sensitivity – more signal • Stepless variable spacing • Smaller spacing • Higher signal 20000 DA 5-HT 15000 S/N of 100 nM standard 10000 5000 0 0 20 40 60 80 100 Spacing SenCell (µm)

  12. [pA] -12 5-HT DA -14 -16 Current -18 100 pM -20 -22 Blank -24 0 1 2 3 4 [min.] Time Sensitivity • LOD • 50 pM DA (0.23 fmol) • 65 pM 5-HT (0.25 fmol) 100 pmole/L standards in Hac + Ringer, 5 uLinjection

  13. Pressure • Higher flow rate due to UHPLC • Smaller spacing down to 10um

  14. Sencell Max Pressure • Leak tight ring • Rating: 25 bar

  15. [nA] 15 5-HT DA 10 Current 5 0 0 0.5 1.0 time (min) UHPLC compatible • High speed analysis • Fast response • Noise level 100 nmole/L standards in Hac, 5 uLinjection

  16. [nA] 15 5-HT DA 10 Current 5 0 0 0.5 1.0 time (min) UHPLC compatible 100 nmole/L standards in Hac, 5 uLinjection

  17. Conclusion • SenCell– The most Easy to use flowcell • Wall jet – performance • Variable spacing - more signal • Less noise by improved fluid dynamics • UHPLC compatible