1 / 18

FISP Technical Committee Meeting May 17, 2011 Timothy D. Straub, P.E ., Ph.D.

LISST-SL Experience and Testing Plan in Illinois. FISP Technical Committee Meeting May 17, 2011 Timothy D. Straub, P.E ., Ph.D. and a long list of others . Experience Summary. 1,194 Files on LISST-SL Topside Controller Box ~180 Samples 10 Sites (2 visits at 3 sites).

jett
Download Presentation

FISP Technical Committee Meeting May 17, 2011 Timothy D. Straub, P.E ., Ph.D.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LISST-SL Experience and Testing Plan in Illinois FISP Technical Committee Meeting May 17, 2011 Timothy D. Straub, P.E., Ph.D. and a long list of others.

  2. Experience Summary • 1,194 Files on LISST-SL Topside Controller Box • ~180 Samples • 10 Sites (2 visits at 3 sites)

  3. Experience Summary Cont. • Concentration • 35 – 6,000 mg/L (recorded by LISST-SL) • Velocity • 1.8 – 8 ft/s • Depth • 2 – 30 ft

  4. Quarterly Shipment Going Out This Week >800 samples (photo from this morning) LISST-SL Testing: ~180 samples- ~50 Sand/Fine Split ~50 Full Particle Size Labs Being Used: ~150 – Kentucky Lab (Pipette/VA) ~30 – CVO Lab (SediGraph/Sieve, Pycnometer) (also has new method for digital imaging full particle size analysis for low concentrations)

  5. Pycnometer Testing Specific Gravity Ranges •Sand: 2.63 – 2.67 •Silt: 2.65 – 2.70 •Clay & SiltyClay: 2.67 – 2.90 •Organic Soils: <2.0

  6. LISST-SL Testing Guidelines Laser In-Situ Scattering and Transmissometry (LISST) Stream Lined (SL) • Background/Clean Water Checks • Before and after testing at a site • Instrument should be left in the water for 35 minutes prior to background checks and testing • Single Vertical Samples • “a”, “b”, and optional “c” samples • Transit rate of the LISST-SL < 1 ft per 5 seconds • Point Samples • “a”, “b”, and optional “c” samples • At least at 0.6 depth, and 0.2, 0.4, and/or 0.8 as conditions allow

  7. Typical Boat Setup

  8. Typical Bridge Setup

  9. Most storms occur at night, on weekends, or holidays

  10. Flashy Sand Site • 3,600 – 1,200 mg/L • from 12 am – 5 am • 30 samples • Concurrent ADCP measurements

  11. Flashy Fines Site • 6,000 – 1,000 mg/L • over 3 hours • 43 samples • Concurrent ADCP measurements • Up-looker surrogate site

  12. Summary Photos

  13. Summary Photos

  14. Summary Photos

  15. Summary Photos

  16. Discussion Items Pitot TubePump

  17. Summary • Good range of testing • Good LISST-SL performance • Results …