ERL Main Linac Cryomodule Internal Cryomodule Instrumentation Peter Quigley, MLC Design Review
MLC Basic Thermal Map Input Couplers and 80K Shield not shown Support Post HGRP BPM 2K 2-Phase Line HOM Load Cavity Helium Vessel SC Magnet Gate Valve Gate Valve 300K ≤ 2K Peter Quigley, MLC Design Review
Cavity, Helium Vessel, Input Coupler, HOM LoadUnit Sensor Layout HOM Load Cavity Helium Vessel Adjacent Cavity /Coupler CERNOX 1050-SD CLTS HOM Load PT1000 Input Coupler 5K Intercept: Gas Input Cavity Field Probe Port (2) 40K Flange: Gas Input Input Coupler 300K Input Coupler Cooling Gas Input/Output ≤ 2K Peter Quigley, MLC Design Review
Sensor Layout For Cryogenics Piping * CERNOX 1050-SD CLTS PT1000 5K forward 5K local 40K delivery 80K return 6.5K return HGRP 40K forward * 2K 2-Phase Line 40K local *Use of a pressure sensor for flow detection is being considered. 300K Pressure Sensor ≤ 2K Peter Quigley, MLC Design Review
General Instrumentation Information • CERNOX 1050-SD RTD (300K to 1.6K). • CLTS (Cryogenic Linear Temperature Sensor) (300K to 4K). • PT1000 RTD (450K to 40K). • Liquid Helium Level Sensor: 2K type, cold feedthrough. • SC Quad: Lead wire feedthrough LHC type or similar. • Piezo sense and actuator: Noliac, tested in HTC-I,II, and III. • Tuner Motor: Cold, tested in HTC-I,II, and III. • Heaters: • One heater per helium vessel mounted on 2K 2Phase Line. • Two heaters per HOM load, 200W each. • Vacuum Monitoring and Control: Open for discussion. • RF cable: Semi-rigid or Flexible coax. Peter Quigley, MLC Design Review
Cavity, Helium Vessel, Input Coupler, HOM LoadAdditional Sensor Layout For Prototype HOM Load Cavity Helium Vessel Adjacent Cavity /Coupler CERNOX 1050-SD CLTS HOM Load PT1000 Input Coupler 5K Intercept: Gas Input Cavity Field Probe Port (2) 40K Flange: Gas Input Input Coupler 300K Input Coupler Cooling Gas Input/Output ≤ 2K Peter Quigley, MLC Design Review