Ecobox 2. Receiver. Pilot wire version. Emiter. ECOBOX 2 – reduction of annual consumption about 25% !!!. Positioning. Locking screw. Choice of the programs. OR. BETWEEN. One of the 7 Recorded programs can be chosen for each day of the week.
E N D
Ecobox 2 Receiver Pilot wire version Emiter ECOBOX 2 – reduction of annual consumption about 25% !!!
Positioning Locking screw
Choice of the programs OR BETWEEN One of the 7 Recorded programs can be chosen for each day of the week 7 Free programs (one by day of the week), each of them can be modified according to te needs Comfort Setback
ECOBOX 2 – program.modes • Mode „COMFORT“ When set at COMFORT, the heaters control your room temperature at your comfort setting, which you select by adjusting the temperature control knob directly on the heaters. These periods correspond to times when you are present. • Mode „ECO- Set back“ When set at ECO, the heaters control your room temperature at 3.5°C lower than your comfort setting. These periods correspond to the times when you are not there or when you are sleeping. • Program „FREEZE GUARD“ When set at FREEZE GUARD, the heaters control your room temperature at 7°C. This seting is used for extended periods of absence or for unoccupied rooms.
Programmation Cassette + -/Hgel ok mode Time Day of week 1 2 3 4 5 6 7 Comfort Hours Today’s program Step by step . 0h . 2 . 4 . 6 . 8 . 10 . 12 . 14 . 16 . 18 . 20 . 22 . 24 Setback Hours LCD Screen
Ecobox 2 Pilot wire + -/Hgel ok mode 1 2 3 4 5 6 7 1 programming cassette by zone . 0h . 2 . 4 . 6 . 8 . 10 . 12 . 14 . 16 . 18 . 20 . 22 . 24
1 2 3 4 5 6 7 1 2 3 4 5 6 7 + -/Hgel ok mode + -/Hgel ok mode 230 V 230 V 230 V 230 V 230 V 230 V Pilot wire principle ZONE 2 ZONE 1 1 cassette by zone ECOBOX 2 Pilot wire ECOBOX 2 Pilot wire
1 2 3 4 5 6 7 1 2 3 4 5 6 7 + -/Hgel ok mode + -/Hgel ok mode 230 V 230 V 230 V 230 V 230 V 230 V Possibility of Pilot wires connection ZONE 2 ZONE 1 1 cassette by zone ECOBOX 2 Pilot wire ECOBOX 2 Pilot wire Switch-board
Connection of pilot wires in the main Switch-board Pilot wire ZONE 1 Pilot wire ZONE 2 ZONE 2 ZONE 1 Terminal
ZONE 2 ZONE 1 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V Change of pilot wire from control of zone1 to zone2 ZONE 2 ZONE 1 ECOBOX 2 Pilot wire ECOBOX 2 Pilot wire ZONE 2 ZONE 1 ECOBOX 2 Pilot wire ECOBOX 2 Pilot wire Pilot wire of controlled convector by Ecobox 2 FP in zone 1 was removed for possibility of controlling by Ecobox 2 from zone2.
1 2 3 4 5 6 7 . 0h . 2 . 4 . 6 . 8 . 10 . 12 . 14 . 16 . 18 . 20 . 22 . 24 + -/Hgel ok mode Mains signalling Transmitter Receiver
1 2 3 4 5 6 7 1 2 3 4 5 6 7 + -/Hgel ok mode + -/Hgel ok mode 230 V 230 V 230 V 230 V 230 V 230 V Mains signalling principle 1 Transmitter in 1 convector by zone and 1 receiver in each other convectors ZONE 2 ZONE 1
Carrier current + -/Hgel ok mode 1 2 3 4 5 6 7 . 0h . 2 . 4 . 6 . 8 . 10 . 12 . 14 . 16 . 18 . 20 . 22 . 24 1 Transmitter in 1 convector by zone 1 receiver in each other convectors
Setting the clock right + -/Hgel ok mode • Press the button « mode » during 2 seconds • Change the hours pressing the buttons « + » or « - » and afterward pressing the button « OK » • Change the minutes pressing the buttons « + » or « - » and afterward pressing the button « OK » • Change the day pressing the buttons « + » or « - » and afterward pressing the button « OK » 1 2 3 4 5 6 7 . 0h . 2 . 4 . 6 . 8 . 10 . 12 . 14 . 16 . 18 . 20 . 22 . 24
1 2 3 4 5 6 7 1 2 3 4 5 6 7 + -/Hgel ok mode + -/Hgel ok mode 230 V 230 V 230 V 230 V 230 V 230 V Type of combined regulation in 2 zones: Ecobox 2 Transmitter-Reciever ; Ecobox 2 Pilot wire Reciever Reciever Reciever 1 Transmitter in 1 convector for1zone Eating room Living room ZONE1 ZONE2 Kitchen Bedroom 1 Ecobox 2 Transmiter Bedroom 2 Ecobox 2 Pilot wire
ZONE 1 MIN HGEL ECO CONF ARRET PROG 1 MAX 2 8 3 7 4 6 5 MIN MIN MIN HGEL ECO CONF ARRET PROG HGEL ECO CONF ARRET PROG HGEL ECO CONF ARRET PROG 1 1 1 MAX MAX MAX 2 2 2 8 8 8 3 3 3 7 7 7 ZONE 2 4 4 4 6 6 6 5 5 5 Living room 20 °C 16 °C Comfort Eco Eating room 6h 8h 12h 14h 18h 19 °C 15 °C Bedroom 1 20 °C 16 °C Comfort Bedroom 2 Eco 6h 7h 20h 20 °C 16 °C
Type of convectors with installed box for ECOBOX 2 (both version) ELITE 3D PRESTANCE 2
Type of convectors,which is possible to control by programming unit Ecobox 2 – Pilot wire version ELITE 3D ECOFLEX SL PHOENIX EL PRESTANCE 2