Test Detail :-

New Model Evaluation Report. MR. VIJAY KUMAR. Test Detail :-. Old model name : KHP 214 New model introduced with New door profile and 5 star rating. Drop test done. Energy consumption test done. Pull down test done. Result OK. Tick ( or ) the following for confirmation:-.

joylyn
Download Presentation

Test Detail :-

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Model Evaluation Report MR. VIJAY KUMAR Test Detail :- • Old model name : KHP 214 • New model introduced with New door profile and 5 star rating. • Drop test done. • Energy consumption test done. • Pull down test done. • Result OK. Tick ( or ) the following for confirmation:-

  2. New Model :- Feature List NEW MODEL OLD MODEL • Features : • Transparent Door Accessories • 5 Star Rating • Paint door • New Door profile Specification: • Capacity kg • Product • Input wattage • Product Dim L x W x H • Packing Dim L x W x H • Weight kg • Voltage • Color 210L Direct cool Refrigerator 115 524 x 650 x 1230 570 x 670 x 1295 Net 36 , Gross 41 220-240V/50Hz DR,MS Old Model Name : KHP 214 NewModelName : KWE215 New Model Sap Code : KWE215XXRDA Pilot Production Date:- 27/12/09

  3. New Model – Change part list

  4. New Model :- PACKING BOX FRONT SIDE

  5. New Model :- EXPLODED VIEWS

  6. New Model :- EXPLODED VIEWS

  7. New Model :- EXPLODED VIEWS

  8. New Model :- WIRING DIAGRAM

  9. Model Test report

  10. PRODUCT TEST REPORT Format No.: Rev. No.: 00 Rev. Date: Event Duration Page : 1 of 6  Tested by Area JUDGE  Test Name Report No. Modification ES 12.11.2009 to 13.11.09 Model Swapnil A/C OK Pull Down Test 43°C VIL 0011 Ref. 200Lts Ref.200 Lts

  11. PRODUCT TEST REPORT Format No.: Rev. No.: 00 Rev. Date: Event Duration Page : 2 of 6  Tested by Area JUDGE  Test Name Report No. Modification ES 13.07.2009 to 14.07.09 Model Swapnil A/C OK Pull Down Test 32°C VIL 0011 Ref. 200 Lts Ref.200 Lts

  12. PRODUCT TEST REPORT Format No.: Rev. No.: 00 Rev. Date: Event Duration Page : 3 of 6  Tested by Area JUDGE  Test Name Report No. Modification ES 14.07.2009 to 15.07.09 Swapnil A/C OK Thermostat cycle test 43°C VIL 0011 Ref. 200Lts Ref.200 Lts

  13. PRODUCT TEST REPORT Format No.: Rev. No.: 00 Rev. Date: Event Duration Page : 4 of 6  Tested by Area JUDGE  Test Name Report No. Modification ES 15.07.2009 to 16.07.09 Model Swapnil A/C OK Thermostat cycle test 32°C VIL 0011 Ref. 200Lts Ref.200 Lts

  14. PRODUCT TEST REPORT Format No.: Rev. No.: 00 Rev. Date: Event Duration Page : 5 of 6  Tested by Area JUDGE  Test Name Report No. Modification ES 17.07.2009 to 18.07.09 Model Swapnil A/C OK Ice Making Test 43°C VIL 0011 Ref. 200Lts Ref.200 Lts

  15. PRODUCT TEST REPORT Format No.: Rev. No.: 00 Rev. Date: Event Duration Page : 6 of 6  Tested by Area JUDGE  Test Name Report No. Modification MP 19.07.2009 to 19.07.09 Model Swapnil A/C OK Ref. 200Lts Stratability Test 43ºC VIL 0011 Ref.200 Lts

  16. PRODUCT TEST REPORT Format No.: Rev. No.: 00 Rev. Date: Event Duration Page : 1 of 1  Tested by Area JUDGE  Test Name Report No. Modification ES 27.11.2009 to 30.11..09 Model Swapnil In OQA OK Door Open Close Test ‘W’ Profile handle Kelvinator W profile handle (190 lts) . • Test Condition:- • one liters 8 bottles in Ref..door. • 10000 time Ref door open close