1 / 18

LI Gain Curves

LI Gain Curves. The Idea: Fit all the information for one strip together->gives constraints on the model and parameters. Each end of the strip is flashed by a different led and read out by; The near end pmt The far end pmt A high gain pin A low gain pin

jude
Download Presentation

LI Gain Curves

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LI Gain Curves • The Idea: Fit all the information for one strip together->gives constraints on the model and parameters. • Each end of the strip is flashed by a different led and read out by; • The near end pmt • The far end pmt • A high gain pin • A low gain pin • Eight sets of measurements at 20 different led intensities Oxford Meeting, January 06 Peter Litchfield

  2. The model • The raw LI data is corrected; • For missing pulses below threshold at low light levels • For saturation of the electronics according to Giles’s LiLinearity correction • Each pmt and pin is then assumed to saturate according to Giles’s function (a pole term) pt= corrected, true, pulse height p= measured pulse height c1, c2 are constants • Any pmt or pin which seems not to be fully represented by the pole is multiplied by a polynomial in the pulse height, gn are constants

  3. The model • Each true value is assumed to be associated with the others by a constant • The superscripts n and f refer to the near and far readout of the led side A or B. Thus • We have 12 equations at each of 20 light levels, 240 measurements and 40 parameters for a fit up to quadratic on all Pmts and Pins. • Fit for parameters using MINUIT/ROOT

  4. Results PB12 • I selected at random Pulser Box 12 and looked, again at random, at some of the Leds. Pulser Box 13 is at the far side. I only look at strips which have the same leds flashed on the two sides. • I run for 100 strips attached to each Led, the plots look the same for all 640 strips but the plots are too big for Powerpoint! • The Pmt’s are fitted up to adc’s of 12000, before they should completely saturate and the Pins are fitted over their whole range • I plot • the residuals etc for individual strips • pt versus p superimposed on one plot for all the strips • I show first details of Led 12 which had significant non-linearity

  5. PB12 Led12 Linear fit For each side B side A side Note • No pole term or polynomial • Near Pmt – Far Pmt non-linear, saturation • Low Gain – High Gain Pin non-linear, non-linearity in the Pins • Lots of structure

  6. PB12 Led 12 Pole+Quadratic B side A side • Note • Most of the structure has gone, still possibly some on the B side

  7. PB12 Led 12 Pole + Quadratic • For each of 100 strips plot 100 equally spaced point of p (x-axis) v pt (y-axis) • Red line is p=pt Note • Generally consistent behavior of the pins for different strips (as expected) • Pin B High Gain has a wriggle • Pmt’s show signs of saturation with pt>p at high adcs • Pmt saturation starts around 6000-8000 adcs

  8. PB12 Led12 • From the linear fit it looks like the B high gain pin and A low gain pins could be non-linear • After some investigation try pin Bhigh with two extra terms (up to p4) and pin Alow with quadratic. • Pins Blow and Ahigh are constrained to be linear • Good fit • The extra terms in Alow improve the 2 but the biggest effect is in Bhigh

  9. PB12 Led12 • My best bet as to what is happening • The Led of course should be the same for all strips. • It looks like there are two bands in Pin B high. I will investigate. They may be just displaced from each other • I will try finding the average parameters for each and fixing them for all strips.

  10. PB12 Led 2 • Fit with a pole + quadratic term • This time it is side A high gain pin which is strongly non-linear, side B pins look OK. • Side A pmt looks mostly linear up to 12000 adc

  11. PB12 Led 2 • Still some structure in side A • Pin probably needs more than a quadratic term

  12. PB12 Led 13 • Pole + quadratic term • Led 13 looks OK • All pins quite linear • Side B pmts seem to saturate more than side A

  13. PB12 Led 13 • No significant structure after a quadratic fit

  14. PB12 Led 15 • Pole + quadratic fit • This one’s a disaster, everything is all over the place • I haven’t had time to investigate it further

  15. PB 12 Led 15 • Lots of structure even after a quadratic fit • Clearly more than one pin has structure • PmtA v PMT B quite flat • High gain v low gain pins have wiggles • Probably just a pin problem • May (or may not) be able to sort it out with higher order fits

  16. Conclusions • It is possible to make reasonable fits to all the data but it requires high order polynomials in some cases • The problem seems to be in the pins, I have not seen any cases where the pmts require more than a pole term. • Not all the pins are affected. The amount of non-linearity varies, maybe there is some in all of them but in some cases it is too small to notice. • I have only looked at one pulser box, I do not know that it is true for others • I have only looked at one month’s data, it will be interesting to see if there is any time variation

  17. How do we do a Pmt Calibration? • We (I?) could examine each pin in turn, make fits and try to determine a parameterisation for every element in the detector. • A lot of work • Hard to automate since only a fraction of pins seem to need fixing • Fits are somewhat sensitive, just throwing MINUIT at them doesn’t work • It may be possible to make a minimal pin correction (pole term?) and get a reasonable parameterisation of the pmt saturation. • This could probably be automated, the fits are less sensitive • Need to check against some fully parameterised channels that the pmt corrections are conserved • We can forget the pins and assume the far pmt is linear and calibrate the near pmt against it • We can check at least a few cases that the pmt parameters are consistent with those from a full fit.

  18. What about the hardware? • Do we care if we don’t understand why the pins don’t work? • Can we be sure that the pmts are working if the pins aren’t? • Is anybody going to work on understanding the pin hardware? • As a first step we could have another attempt at a swap of a pin readout board?