1 DOOR-TURNSTILE CF CONTROLLER. NO. OUT READER. IN READER. +12V----- RED 0V ------BLACK D1-----WHITE D0-----GREEN GLED----ORANGE (AY-H020) GLED-----BROWN (RD-J12) GLED-----GREY (AY-Y20B) BUZZ-----PURPLE(AY-Y20B) BUZZ-----YELLOW(AY-H020). COM. GLED. ENTRY PUSH BUTTON. GLED.
E N D
1 DOOR-TURNSTILE CF CONTROLLER NO OUT READER IN READER +12V----- RED 0V ------BLACK D1-----WHITE D0-----GREEN GLED----ORANGE (AY-H020) GLED-----BROWN (RD-J12) GLED-----GREY (AY-Y20B) BUZZ-----PURPLE(AY-Y20B) BUZZ-----YELLOW(AY-H020) COM GLED ENTRY PUSH BUTTON GLED BUZ 12V 12V 0V D1 D0 D0 D1 0V NO COM EXIT PUSH BUTTON 12V 0V D1 D0 D1 D0 L1 BZ TP DS PB L2 IN1 IN2 0V Note: 1. JP4, JP5 and JP6 are to set the respective relay to normally open and closed All relay are set to normally open for Car Park Barrier and are of dry contact 2. If DS and PB have not connect to 0V, it cannot provide a signal to turnstile 3. Please do not connect reader unshielded cable and reader any cable to earth. DOOR 1 JP3 JP2 RJ-45 TURNSTILE PANEL NORMAL / RESET JP1 NO/NC EXIT TO TURN LEFT JP8 C2 JP10 02 RY 2 PWR C1 JP9 01 AC ENTRY TO TURN RIGHT 0V RY 1 +12 JP6 14VAC # For Best Result Please solder the wire tip before termination RY 2 JP5 NO/NC JP7 - + 230VAC JP4 RY 1 Battery RELAY SETTING closed- power / open- dry contact JP4 is for relay 2 (RY2) JP4 is for relay 1 (RY11) SHORT