1 / 10

Issues in voxel-based analysis of PV-corrected data

Issues in voxel-based analysis of PV-corrected data. Mario Quarantelli Biostructure and Bioimaging Institute – CNR Naples - Italy HBM2004 - PVEOut Satellite Meeting Budapest, 12 June 2004.

jun
Download Presentation

Issues in voxel-based analysis of PV-corrected data

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Issues in voxel-based analysisof PV-corrected data Mario Quarantelli Biostructure and Bioimaging Institute – CNR Naples - Italy HBM2004 - PVEOut Satellite Meeting Budapest, 12 June 2004 IBB, 2004

  2. Previous studies with voxel-based PV-C images have used voxel-based analysis to detect differences between patients and controls • Ibanez V, et al. Neurology 1998; 50:1585 • Bokde AL, et al. 2001;58:480 • Sakamoto S, et al. J Neuroimaging 2003; 13:113-123 • Matsuda H, et al. Eur J Nucl Med Mol Imaging 2004;29:1502 IBB, 2004

  3. Smoothing • Voxel-based analysis, in its most diffuse implementations, involves smoothing of the images • Inherent to the warping step, performed to adapt the study to a standard normalized space (e.g. “normalization” step in SPM) • Added to reduce noise and to guarantee that residuals have a normal distribution, to apply statistical tests IBB, 2004

  4. Smoothing • Typically, the analysis of uncorrected PET / SPET data will highlight regions in which the overall tracer content is decreased, as a consequence of either GM loss and/or reduced tracer uptake • In its simplest conception, the aim of PV-C is to detect areas with a tracer concentration lower than what we would expect based on the corresponding degree of atrophy • The local re-distribution of the activity, as a consequence of smoothing, may re-introduce a difference in areas with atrophy • (theoretically, if maximum warping is allowed during the normalization process, such that the GM of the patients is deformed to perfectly match the GM of the template, this would solve the problem) IBB, 2004

  5. Testing • Three sets of simulated PET • 10 NV segmented MR studies brought to PET voxel size (2.03x2.03x2.43mm), with GM=255, WM=64 • Same 10 studies with -20% activity in Left Parietal • Same 10 studies with -23.7% GM in Left Parietal (using an erosion algorithm) • All studies PV-C using mMG in PVELab IBB, 2004

  6. SPM Analysis • 4 comparisons: • Uncorrected NV vs. Hypo • Uncorrected NV vs. Atrophic • PV-corrected NV vs. Hypo • PV-corrected NV vs. Atrophic • Unpaired T-Test • No Grand-mean scaling • Threshold masking fixed (20) • Global calculation: Mean Voxel Value • W/O Non-sphericity correction • Uncorrected P<0.001 • No restriction to voxel size IBB, 2004

  7. Original -20% -31% GM IBB, 2004

  8. IBB, 2004

  9. IBB, 2004

  10. Preliminary results • In simulated atrophy, smoothing partly re-introduces PVE • Reduction in cluster size when applying PVC to simulated hypometabolism will result mainly from zeroing of non-brain voxels in PVC images (increased noise in PVC images may also play a role) • Alternative analysis techniques should be exploited • Group X Modality Interaction (Richardson MP,et al. Brain (1997), 120, 1961–1973) • Voxel-based analysis of uncorrected data  definition of VOI  confirmation of hypometabolism with VOI-based PVC IBB, 2004

More Related