1 / 16

A Waveform Consistency Test for Binary Inspirals using LIGO data

A study on testing waveform consistency for binary inspirals using LIGO data through template-based matched filtering. The analysis involves transforming data to the frequency domain, calculating templates, signal-to-noise ratios, and setting thresholds for trigger detections. The method aims to reduce false alarms and improve detection accuracy in gravitational wave observations.

Download Presentation

A Waveform Consistency Test for Binary Inspirals using LIGO data

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A Waveform Consistency Test for Binary Inspirals using LIGO data Andres C. Rodriguez Gabriela González (Louisiana State University) Peter Shawhan (LIGO | Caltech) Evan Oshsner (University of Maryland) LSC Inspiral Analysis Working Group LIGO-G050236-00-Z American Physical Society April Meeting 4.16.05

  2. LIGO Observatories Hanford: two interferometers in same vacuum envelope (4km(H1), 2km(H2)) Livingston: one interferometer (4km(L1)) American Physical Society April Meeting 4.16.05 02

  3. Template based Matched Filtering Template based Matched Filtering • Data stream searched using matched filtering between • data & template waveform. • Transform data to frequency domain : s(f) • Calculate template in frequency domain: h(f) s(t) = n(t) + h(t) ~ ~ American Physical Society April Meeting 4.16.05 03

  4. Template based Matched Filtering • Signal to Noise (): • 2: American Physical Society April Meeting 4.16.05 04

  5. Template based Matched Filtering - Thresholds • Signal to Noise (): • 2 : • » really: • So if  > * and r2 < r2* --> inspiral “trigger”  > threshold (* ) < threshold (r2*) American Physical Society April Meeting 4.16.05 05

  6. Simulated Inspiral (Injection) Injection * SNR r2* r2 -2 0 +2 time (s) to inferred coalescence American Physical Society April Meeting 4.16.05 06

  7. Injection vs. Trigger Injection Trigger SNR r2 -2 0 +2 time (s) to inferred coalescence American Physical Society April Meeting 4.16.05 06

  8. Injection vs. Trigger Injection Trigger r2 -2 0 time (s) to inferred coalescence American Physical Society April Meeting 4.16.05 07

  9. The Test • Use the r2 time series as a method to search for excess noise • Impose a “looser” r2 threshold than the search employs • » Count the number of time samples above a given • threshold in a time interval before inferred coalescence • » Count the number of threshold crossings • Time interval “window” chosen to be 2 seconds • Do my triggers behave like software, hardware injections? • » yes ->> keep • » no ->> veto American Physical Society April Meeting 4.16.05 08

  10. 2 , r2 distribution log10(counts) 0 200 70 r2 0 2 American Physical Society April Meeting 4.16.05 09

  11. 2 , r2 distribution log10(counts) 0 40 12 r2 0 2 American Physical Society April Meeting 4.16.05 09

  12. Injection vs. Trigger Crossings = 0 Time above Threshold = 0 sec Crossings = 52 Time above Threshold = 0.9 sec r2 looser r2 threshold American Physical Society April Meeting 4.16.05 10

  13. Preliminary Results for H1 Injections + Playground Data r2 threshold = 10 window H1 Injections Time above r2 threshold (ms)  American Physical Society April Meeting 4.16.05 11

  14. Preliminary Results for H1 Injections + Playground Data r2 threshold = 10 H1 Injections Time above r2 threshold (ms)  American Physical Society April Meeting 4.16.05 11

  15. Preliminary Results: H1 Injections + Playground Data possibly vetoed r2 threshold = 10 Crossings < 2 H1 Injections Triggers Time above r2 threshold (ms)  American Physical Society April Meeting 4.16.05 11

  16. Summary and Plans • Preliminary testing r2 thresholds set to 6, 8, & 10. • The test would be able to eliminate many of our loudest • false triggers --> reduces false alarm rate. • Additional tuning using S3 Hardware Injections and • testing on S3 playground data from L1,H2. • Will be incorporated into S3, S4 BNS search, and future • online analysis. American Physical Society April Meeting 4.16.05 12