An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Rosemount Analytical Liquid Analytical Instruments

  2. The Platforms Model 5081 Model 54e Model 6081 Model XMT Model 1056 Model 1057 2-Wire 4-Wire Wireless

  3. Model 1056 • Large Backlit Display • Large PV Font • 4 secondary values • Error warning Flag • 4 Alarm status Flags • Diagnostic Button • Multi-language text • Troubleshooting and Help screens

  4. Polycarbonate UV Resistant ½ DIN cut-out Panel Mount/Pipe mount Hinged Door NEMA 4X, IP65 SS Panel Mount Clamps SS Captive Screws Enclosure

  5. Modular Design Sensor Boards Power Supply Board (115/230 VAC board shown) Display/ Main Board

  6. Wiring • Sensor Boards slide out for easy access • No hardware to de-install • Compression bridge holds board in place • Cable Guides • Clean wiring

  7. Wiring • Signal input board and terminal designations are clearly marked • Each sensor lead is identified

  8. Model 1056 Hardware • Power supply ordering option: • -01 Basic (115/230 VAC) • -02 (24VDC) • -03 (85 – 265 AC switching Power Supply) • 4 fully programmable relays • 4 x SPDT (Form C) relays with high load 5A rating for long life • Failsafe operation – programmable default state (NO or NC) • Programmable: deadband, interval time, on time, recover time • Supports USP conductivity alarms in Pharma applications

  9. Model 1056 Measurement • pH/ORP/ISE • Contacting Conductivity • Linear (%/C) Temp correction • Neutral Salt Temp correction • Cation Conductivity Temp correction • Resistivity • Inductive Conductivity • Linear (%/C) Temp correction • % Concentration • Amperometric • Dissolved oxygen (ppm, ppb & % Sat) • Gaseous oxygen (%) • Total, Free & Mono Chlorine • Ozone

  10. Model 1056 Measurement • 4-20mA Input • Supports 4-20mA Input from an external device • Enables live continuous compensation • Live input reading viewed on main display • Ordering option -23, -33 (same as Pulse Flow board) • Primary applications • Temperature (alternative to sensor RTD input) • Barometric Pressure (for oxygen partial pressure compensation) • Pulse Flow • Supports pulse input type sensors • Supports popular GF Signet 515 flow sensor

  11. Model 1056 Measurement Compatible with all SMART pH Sensors: • PERpH-X, TUpH, triple junction, high purity, special app’s • VP8 compatible • Integral preamp in sensor • Plug and Play compatibility • Automatic calibration – cal data upload • SMART line covers all normal pH applications

  12. Model 1056 HART Digital Communications • HART Smart Digital Communications • Available with all measurement configurations • Easy and accessible wiring to current output 1 • Complete HART diagnostics • Local wiring of Model 375/475 HART communicator to the instrument • Complete on-screen menus for HART parameters • HART menus in 7 local languages

  13. Model 1056 Profibus DP Digital Communications • Profibus DP Digital Communications • Available with all measurement configurations • DP protocol supports communication between automation control systems and distributed input/output devices • Hardware: Slide-in communications board • Two ways to interface the network: • Direct wiring of Profi (purple) cable to Profi board (+, -) • M12 Adaptor kit wired to Profi board (+, -, 5v, gnd) • Common connectivity accessories offered • M12 Adaptor kit • Adaptors, T’s, and in-line cable assemblies

  14. Model 1056 “The Model 1056 is the best line-powered liquid measurement instrument on the market today - bar none.” 3 year Warranty

  15. Model 1057 Liquid Analyzer 3 Channel pH and Contacting Conductivity Analyzer

  16. Model 1057 Key Features • 3 inputs: pH, contacting conductivity – any combo. • 4 current outputs • Fully Isolated inputs and outputs • Large Display with user friendly menus, 8 languages • Modular signal boards, field upgrade, replacement • Quick Start and Auto Sensor recognition • Polycarbonate enclosure – wall, pipe, panel • Diagnostics and User Help screens • SMART sensor compatibility – Access Cal Data • UL and CSA certification

  17. Model 54e Controller

  18. Model 54e Key Features • Back-lit Display • 24VDC Power Option • Control Capability • PID on Outputs • TPC on Relays • HART digital communications • Ruggedized Aluminum case

  19. Model 54e Control Capability • Code Option -20 • Includes control functions when purchased • Each process alarm and each output is independently configured • Choice of control on process measurement or temperature • Control Capability • PID on Outputs • TPC on Relays

  20. Model 54e vs. Model 1056

  21. Model 5081

  22. Model 5081 Key Features • Designed for very harsh environments • Configuration methods • Handheld IR remote • Model 375/475 HART communicator • Control system protocol via Host • Exceptional ease of use • Menu driven • Large easy to read display • 20mm character height • Fault and Warning messages • Selectable conductivity ranges 5081-T, -C • I.S and N.I. Agency Certification

  23. Model 5081 User Interfaces • Infrared Remote Controller • Allows Access to the Transmitter in the Field • Can Configure Transmitter Parameters • HART • Model 375/475 HART Communicator • HART Host • DeltaV • Foundation fieldbus • DeltaV via H1 card

  24. Model Xmt

  25. Model Xmt Key Features • Intuitive 2-wire transmitter • Simple menu structure • Clear easy-to-read display • Digital Communication Protocol Choices • HART • Foundation fieldbus/FISCO • Panel, pipe & surface mounting • Complete measurement capabilities • pH, ORP, Contacting and Toroidal Conductivity, Dissolved Oxygen, Chlorine & Ozone • Six local languages

  26. Model Xmt Specifications • Panel, pipe or surface mounting • NEMA 4X/IP65 enclosure • Easy to use menus • Two line 16 character display • Agency Certification • CE (RFI/EMI) • FM (I.S. & N.I). • CSA (I.S. & N.I). • ATEX (I.S.)

  27. Model Xmt Specifications continued • Enclosure • Panel mount • ½ DIN cut out • IP65, NEMA 4X • Surface/Pipe mount • Only 82mm deep • IP65, NEMA 4X • Power Requirements • 12 to 30Vdc (HART) • 9 to 32Vdc (-FF, -FI)

  28. 6081-C Rosemount Analytical Wireless Products 6081-P Wireless THUM Adaptor

  29. 6081-C 6081-P Wireless Product Line + + Released Sept. 29 2009 * 6081-P + 6081-C + THUM cover 99% of applications Released June 26 2009 * 6081-P + 6081-C cover 70% of applications Released April 1 2008 * 6081-P covers 40% of customer applications

  30. 6081-C 6081-P Analytical Family – Model 6081 Wireless devices for most applications: • Model 6081-P – pH, ORP and REDOX • Model 6081-C – contacting conductivity • Wireless HART compliant • Compatible with AMS v. 10.X • Monitoring or Control Applications • Industrial, Commercial, Municipal uses • Ideal for Remote, Hazardous or Inaccessible sites

  31. 6081-C 6081-P Model 6081 Family Capabilities • Key Features - 6081-C and 6081-P • HART v.7 WirelessHART Compliant • Local access for network setup • Local menus – calibration, programming • Intrinsically Safe design • Intelligent power management • Menus in 6 local Languages • 1 sec. to 60 min. update rates • Quick Start Programming • Supports Multiple Menu Languages

  32. Model 6081-P Features • Key Features – pH and ORP • Auto buffer Calibration • Compatible with conventional pH and ORP Sensors • Local Fault and Warning indications • Advanced Diagnostics • Power Module Life: 6 Years@1/min. update rate, 25°C (pH only) • SMART-enabled • Automatic loop calibration • Calibration history stored via AMS

  33. Model 6081-C Features • Key Features – Contacting Conductivity • Wide range conductivity measurement • 2-electrode and 4-electrode sensors • High accuracy and linearity across range • 1-step calibration with cell constant • Local Fault and Warning indications • Power Module Life: 4 Years@1/min. update rate, 25°C

  34. 0-WIRE, 2-WIRE & 4-WIRE MEASUREMENTS Most features are shared in common on all platforms

  35. pH Measurement • Range 0-14 pH • Temperature compensation: • Pt100 or Pt1000 auto-sensing • Manual • Automatic (ref: 25C) • Automatic buffer recognition • Buffers choices:1.68, 3.56, 3.78, 4.01, 6.86, 7.00, 9.18, 10.01, 12.45 • Stability: user-defined X.XXpH in XX seconds • Preamplifier location is menu selectable • In Sensor or junction box

  36. ORP/Redox Measurement • Read either ORP or Redox (opposite sign) • Range -1400 to +1400 mV • Calibration • Single point against standard solution • Temperature compensation • Not used, however temperature can be read for Pt100 or Pt1000

  37. Contacting Conductivity • Intended for use with Model 400 ENDURANCE sensors, but can be use with any contacting sensor. • Model 410VP 4-Electrode (1056/1057/6081 only) • Range 0-20,000 uS/cm (depends on cell constant). • Measure conductivity, resistivity, or TDS. • Temperature corrections: • Linear/percent slope (0-5%/°C) • high purity water (dilute sodium chloride) • cation conductivity (dilute hydrochloric acid) • raw (no temperature correction)

  38. Toroidal Conductivity • Can be used with 222, 225, 226, 228, 242, 245, and 247 sensors. • Range: 50 - 2,000,000 uS/cm (sensor-dependent) • Concentration curves: • 0-12% NaOH • 0-15% HCl • 0-25% and 96.0 to 99.7% H2SO4 • 0-20% NaCl • Custom (2-5 data points)

  39. Amperometric Measurements • Chlorine, Dissolved Oxygen, Ozone • 1056/1057 and Xmt-A wakes up with no polarizing voltage. • Eliminates increased startup times caused by applying the wrong polarizing voltage to a sensor.

  40. Chlorine Measurement • Customer selects measurement • Free Chlorine, Total Chlorine or Monochloramine • Automatic pH correction for free chlorine • valid between pH 6.0 to 10.0 • needed if pH changes more than 0.2 units in-process • Recommended sensors • 499ACL-01 for free chlorine • 499ACL-02 for total chlorine • 499ACL-03 for monochloramine

  41. Dissolved Oxygen Measurement • Sensors, 499ADO, 499ATrDO, Hx438, Gx448, Bx438 • Compatible with steam-sterilizable DO sensors from other manufacturers. • Units: ppm, ppb, % saturation • Temperature compensation: Automatic 0-50OC • Calibration • Air calibration • User entry of atmospheric pressure on 2-wire devices • Atmospheric pressure sensor on 4-wire devices • Standardization • portable instrument • grab sample analysis

  42. Ozone Measurement • Sensor: 499AOZ • Selectable units: ppm or ppb • 0-10 ppm (mg/l) • Auto temperature correction • Resolution 0.001ppm (1ppb) • Automatic temperature compensation • 5 to 35OC • Calibration • Against grab sample with portable test kit

  43. 2-Wire Competitors