640 likes | 1.17k Views
Rosemount Analytical Liquid Analytical Instruments. The Platforms. Model 5081. Model 54e. Model 6081 . Model XMT. Model 1056. Model 1057. 2-Wire. 4-Wire. Wireless. Model 1056. Large Backlit Display Large PV Font 4 secondary values Error warning Flag 4 Alarm status Flags
E N D
The Platforms Model 5081 Model 54e Model 6081 Model XMT Model 1056 Model 1057 2-Wire 4-Wire Wireless
Model 1056 • Large Backlit Display • Large PV Font • 4 secondary values • Error warning Flag • 4 Alarm status Flags • Diagnostic Button • Multi-language text • Troubleshooting and Help screens
Polycarbonate UV Resistant ½ DIN cut-out Panel Mount/Pipe mount Hinged Door NEMA 4X, IP65 SS Panel Mount Clamps SS Captive Screws Enclosure
Modular Design Sensor Boards Power Supply Board (115/230 VAC board shown) Display/ Main Board
Wiring • Sensor Boards slide out for easy access • No hardware to de-install • Compression bridge holds board in place • Cable Guides • Clean wiring
Wiring • Signal input board and terminal designations are clearly marked • Each sensor lead is identified
Model 1056 Hardware • Power supply ordering option: • -01 Basic (115/230 VAC) • -02 (24VDC) • -03 (85 – 265 AC switching Power Supply) • 4 fully programmable relays • 4 x SPDT (Form C) relays with high load 5A rating for long life • Failsafe operation – programmable default state (NO or NC) • Programmable: deadband, interval time, on time, recover time • Supports USP conductivity alarms in Pharma applications
Model 1056 Measurement • pH/ORP/ISE • Contacting Conductivity • Linear (%/C) Temp correction • Neutral Salt Temp correction • Cation Conductivity Temp correction • Resistivity • Inductive Conductivity • Linear (%/C) Temp correction • % Concentration • Amperometric • Dissolved oxygen (ppm, ppb & % Sat) • Gaseous oxygen (%) • Total, Free & Mono Chlorine • Ozone
Model 1056 Measurement • 4-20mA Input • Supports 4-20mA Input from an external device • Enables live continuous compensation • Live input reading viewed on main display • Ordering option -23, -33 (same as Pulse Flow board) • Primary applications • Temperature (alternative to sensor RTD input) • Barometric Pressure (for oxygen partial pressure compensation) • Pulse Flow • Supports pulse input type sensors • Supports popular GF Signet 515 flow sensor
Model 1056 Measurement Compatible with all SMART pH Sensors: • PERpH-X, TUpH, triple junction, high purity, special app’s • VP8 compatible • Integral preamp in sensor • Plug and Play compatibility • Automatic calibration – cal data upload • SMART line covers all normal pH applications
Model 1056 HART Digital Communications • HART Smart Digital Communications • Available with all measurement configurations • Easy and accessible wiring to current output 1 • Complete HART diagnostics • Local wiring of Model 375/475 HART communicator to the instrument • Complete on-screen menus for HART parameters • HART menus in 7 local languages
Model 1056 Profibus DP Digital Communications • Profibus DP Digital Communications • Available with all measurement configurations • DP protocol supports communication between automation control systems and distributed input/output devices • Hardware: Slide-in communications board • Two ways to interface the network: • Direct wiring of Profi (purple) cable to Profi board (+, -) • M12 Adaptor kit wired to Profi board (+, -, 5v, gnd) • Common connectivity accessories offered • M12 Adaptor kit • Adaptors, T’s, and in-line cable assemblies
Model 1056 “The Model 1056 is the best line-powered liquid measurement instrument on the market today - bar none.” 3 year Warranty
Model 1057 Liquid Analyzer 3 Channel pH and Contacting Conductivity Analyzer
Model 1057 Key Features • 3 inputs: pH, contacting conductivity – any combo. • 4 current outputs • Fully Isolated inputs and outputs • Large Display with user friendly menus, 8 languages • Modular signal boards, field upgrade, replacement • Quick Start and Auto Sensor recognition • Polycarbonate enclosure – wall, pipe, panel • Diagnostics and User Help screens • SMART sensor compatibility – Access Cal Data • UL and CSA certification
Model 54e Key Features • Back-lit Display • 24VDC Power Option • Control Capability • PID on Outputs • TPC on Relays • HART digital communications • Ruggedized Aluminum case
Model 54e Control Capability • Code Option -20 • Includes control functions when purchased • Each process alarm and each output is independently configured • Choice of control on process measurement or temperature • Control Capability • PID on Outputs • TPC on Relays
Model 5081 Key Features • Designed for very harsh environments • Configuration methods • Handheld IR remote • Model 375/475 HART communicator • Control system protocol via Host • Exceptional ease of use • Menu driven • Large easy to read display • 20mm character height • Fault and Warning messages • Selectable conductivity ranges 5081-T, -C • I.S and N.I. Agency Certification
Model 5081 User Interfaces • Infrared Remote Controller • Allows Access to the Transmitter in the Field • Can Configure Transmitter Parameters • HART • Model 375/475 HART Communicator • HART Host • DeltaV • Foundation fieldbus • DeltaV via H1 card
Model Xmt Key Features • Intuitive 2-wire transmitter • Simple menu structure • Clear easy-to-read display • Digital Communication Protocol Choices • HART • Foundation fieldbus/FISCO • Panel, pipe & surface mounting • Complete measurement capabilities • pH, ORP, Contacting and Toroidal Conductivity, Dissolved Oxygen, Chlorine & Ozone • Six local languages
Model Xmt Specifications • Panel, pipe or surface mounting • NEMA 4X/IP65 enclosure • Easy to use menus • Two line 16 character display • Agency Certification • CE (RFI/EMI) • FM (I.S. & N.I). • CSA (I.S. & N.I). • ATEX (I.S.)
Model Xmt Specifications continued • Enclosure • Panel mount • ½ DIN cut out • IP65, NEMA 4X • Surface/Pipe mount • Only 82mm deep • IP65, NEMA 4X • Power Requirements • 12 to 30Vdc (HART) • 9 to 32Vdc (-FF, -FI)
6081-C Rosemount Analytical Wireless Products 6081-P Wireless THUM Adaptor
6081-C 6081-P Wireless Product Line + + Released Sept. 29 2009 * 6081-P + 6081-C + THUM cover 99% of applications Released June 26 2009 * 6081-P + 6081-C cover 70% of applications Released April 1 2008 * 6081-P covers 40% of customer applications
6081-C 6081-P Analytical Family – Model 6081 Wireless devices for most applications: • Model 6081-P – pH, ORP and REDOX • Model 6081-C – contacting conductivity • Wireless HART compliant • Compatible with AMS v. 10.X • Monitoring or Control Applications • Industrial, Commercial, Municipal uses • Ideal for Remote, Hazardous or Inaccessible sites
6081-C 6081-P Model 6081 Family Capabilities • Key Features - 6081-C and 6081-P • HART v.7 WirelessHART Compliant • Local access for network setup • Local menus – calibration, programming • Intrinsically Safe design • Intelligent power management • Menus in 6 local Languages • 1 sec. to 60 min. update rates • Quick Start Programming • Supports Multiple Menu Languages
Model 6081-P Features • Key Features – pH and ORP • Auto buffer Calibration • Compatible with conventional pH and ORP Sensors • Local Fault and Warning indications • Advanced Diagnostics • Power Module Life: 6 Years@1/min. update rate, 25°C (pH only) • SMART-enabled • Automatic loop calibration • Calibration history stored via AMS
Model 6081-C Features • Key Features – Contacting Conductivity • Wide range conductivity measurement • 2-electrode and 4-electrode sensors • High accuracy and linearity across range • 1-step calibration with cell constant • Local Fault and Warning indications • Power Module Life: 4 Years@1/min. update rate, 25°C
0-WIRE, 2-WIRE & 4-WIRE MEASUREMENTS Most features are shared in common on all platforms
pH Measurement • Range 0-14 pH • Temperature compensation: • Pt100 or Pt1000 auto-sensing • Manual • Automatic (ref: 25C) • Automatic buffer recognition • Buffers choices:1.68, 3.56, 3.78, 4.01, 6.86, 7.00, 9.18, 10.01, 12.45 • Stability: user-defined X.XXpH in XX seconds • Preamplifier location is menu selectable • In Sensor or junction box
ORP/Redox Measurement • Read either ORP or Redox (opposite sign) • Range -1400 to +1400 mV • Calibration • Single point against standard solution • Temperature compensation • Not used, however temperature can be read for Pt100 or Pt1000
Contacting Conductivity • Intended for use with Model 400 ENDURANCE sensors, but can be use with any contacting sensor. • Model 410VP 4-Electrode (1056/1057/6081 only) • Range 0-20,000 uS/cm (depends on cell constant). • Measure conductivity, resistivity, or TDS. • Temperature corrections: • Linear/percent slope (0-5%/°C) • high purity water (dilute sodium chloride) • cation conductivity (dilute hydrochloric acid) • raw (no temperature correction)
Toroidal Conductivity • Can be used with 222, 225, 226, 228, 242, 245, and 247 sensors. • Range: 50 - 2,000,000 uS/cm (sensor-dependent) • Concentration curves: • 0-12% NaOH • 0-15% HCl • 0-25% and 96.0 to 99.7% H2SO4 • 0-20% NaCl • Custom (2-5 data points)
Amperometric Measurements • Chlorine, Dissolved Oxygen, Ozone • 1056/1057 and Xmt-A wakes up with no polarizing voltage. • Eliminates increased startup times caused by applying the wrong polarizing voltage to a sensor.
Chlorine Measurement • Customer selects measurement • Free Chlorine, Total Chlorine or Monochloramine • Automatic pH correction for free chlorine • valid between pH 6.0 to 10.0 • needed if pH changes more than 0.2 units in-process • Recommended sensors • 499ACL-01 for free chlorine • 499ACL-02 for total chlorine • 499ACL-03 for monochloramine
Dissolved Oxygen Measurement • Sensors, 499ADO, 499ATrDO, Hx438, Gx448, Bx438 • Compatible with steam-sterilizable DO sensors from other manufacturers. • Units: ppm, ppb, % saturation • Temperature compensation: Automatic 0-50OC • Calibration • Air calibration • User entry of atmospheric pressure on 2-wire devices • Atmospheric pressure sensor on 4-wire devices • Standardization • portable instrument • grab sample analysis
Ozone Measurement • Sensor: 499AOZ • Selectable units: ppm or ppb • 0-10 ppm (mg/l) • Auto temperature correction • Resolution 0.001ppm (1ppb) • Automatic temperature compensation • 5 to 35OC • Calibration • Against grab sample with portable test kit