ATV71-ATV61 for DH Bach Khoa. Summary. ATV71 MAIN FEATURES ATV71 FUNCTIONS Functions by application Input / output configuration* Preset speeds* Speed control Torque control Current / Torque limitation* PID regulator
E N D
Summary ATV71 MAIN FEATURES ATV71 FUNCTIONS Functions by application Input / output configuration* Preset speeds* Speed control Torque control Current / Torque limitation* PID regulator Low speed time out Master / slave in speed* Master / slave in torque Brake logic control Auto DC injection* Dynamic braking* Load sharing Direct power supply via DC bus* Parameter set switching* Multimotor-Multiconfiguration* Positionning by sensors ATV61 MAIN FEATURES ATV61 FUNCTIONS Functions by application PID regulator Sleep / Wake up Monitoring the speed reference No flow detection Flow limitation Process underload detection Process overload detection Fault inhibition Speed control Other functions common with ATV71* OPTION CARDS Input / output extension Encoder board Controller Inside board Communication boards Application card MAINTENANCE Diagnostics & Trouble shooting
The ATV71 is a homogenous range of variable speed drives from 0.37 to 630kW It is designed for the industrial sector, for constant torque applications Its principal targets are the following applications: Hoisting Elevator Material Handling Packaging Textile Machines Woodworking Machines Process Control Machines High Inertia Machines ... ATV71 MAIN FEATURES Introduction
The ATV71 integrates numerous dedicated application functions as well as different types of motor control. It is delivered with a standard graphic terminal It is a communicating product offering a large choice of protocols with Modbus and CAN open as standard. The option cards make it possible to extend the input-output and programming capacity to respond to complex applications. It is a product designed for a global market It conforms to the principal norms and international directives among others EMC, harmonics, safety, environment... ATV71 MAIN FEATURES Introduction
The Altivar 71 covers the motor powers between 0.37 kW and 630 kW 380 - 480V three phase, from 0.75 kW to 500 kW 500 - 690V three phase, from 1.5 kW to 630 kW 200 - 240V three phase, from 0.37 kW to 75 kW (Single phase operation possible up to 5.5kW) ATV71 MAIN FEATURES The product range
ATV71 MAIN FEATURES The product range 220-480V
ATV71 MAIN FEATURES Base product architecture
ATV71 AIN FEATURES Base product architecture Modbusor PowerSuite ModbusCanOpen
ATV71 MAIN FEATURES Software architecture
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Functions by application
ATV71 FUNCTIONS Input / output configuration
ATV71 FUNCTIONS Input / output configuration
ATV71 FUNCTIONS Preset speeds Note: ATV61 has only 8 preset speeds
ATV71 FUNCTIONS Speed control • The ATV71 includes several motor control laws. • These different laws allow the drive to be adapted to a great variety of induction motors and machines. • SVC-U Voltage Sensorless Vector Control • SVC-I Current Sensorless Vector Control* • FVC Flux Vector Control (closed loop)* • U/F Volt/Hertz • SYN Synchronous motor (open loop) • (*) specific to ATV71
ATV71 FUNCTIONS Speed controlSVC-U Voltage vector control is a compromise between performance and robustness. It functions only in open loop Applications: Hoisting General material-handling equipment Machines requiring low speed torque Motors in parallel Unbalanced loads with the ENA function Performances: Good dynamic characteristics Overtorque from 170% to more than 200%, depending upon the motor and the optimization of the settings (current limit adjustable from 150% to 165% In of the drive) Nominal torque down to 1Hz (0.5Hz with optimization) in motor quadrant Nominal torque at slipping frequency in generator quadrant
ATV71 FUNCTIONS Speed controlSVC-U Performances (cont’d): Maximum frequency of 500Hz Speed precision <=10 % of nominal slip Speed range 50 in motor quadrant (100 with optimization), depending on the slipping in generator quadrant It can be used with motors in parallel Band pass: 0.37 to 2.2kW 15 Hz 3 to 7.5kW 12 Hz 7.5 to 75kW 10 Hz 280 kW 4 Hz 500 kW 2 Hz These performances are guaranteed for a motor of the same size than the drive and up to one size below. The input of the nameplate and the autotune are necessary to obtain the optimum performances.
ATV71 FUNCTIONS Speed controlSVC-U
ATV71 FUNCTIONS Speed controlSVC-U
ATV71 FUNCTIONS Speed controlSVC-I & FVC The current vector control law allows the drive to attain better static and dynamic performance for torque and speed Requires a good understanding of the motor characteristics It functions in open (SVC-I) or closed loop (FVC) Applications: Vertical hoisting movements High process rate machines Rapid material-handling Positioning Base law for the torque control function Performances: Very good dynamic speed and torque characteristics Overtorque from 170% to more than 200% (depending on motor) Maximum frequency 500Hz The motor nameplate information and TUN are required. Flux feedback permits the improvement of braking performance without a braking resistor
ATV71 FUNCTIONS Speed controlSVC-I & FVC Performance in open loop (SVC-I) The general performance is comparable to voltage vector control with better torque precision and better fluxed braking Can be used with motors in parallel if the motors are identical Nominal torque down to 1Hz (0.5hz with optimization) in motor quadrant Nominal torque at slipping frequency in generator quadrant Speed precision <=10 % of nominal slip Speed range 50 in motor quadrant (100 with optimization), depending on the slipping in generator quadrant Torque control mode: Precision 15% Up to +/-300% of nominal torque (Tn)
ATV71 FUNCTIONS Speed controlSVC-I & FVC
ATV71 FUNCTIONS Speed controlSVC-I & FVC
ATV71 FUNCTIONS Speed controlSVC-I & FVC
ATV71 FUNCTIONS Speed controlSVC-I & FVC Performance in closed loop (FVC) Torque at 0 speed is available in motoring or generating quadrant Speed precision is 0.02% of the nominal speed Speed range 1000 Band pass: 0.37 to 2.2kW 50 Hz 3 to 7.5kW 30 Hz 7.5 to 75kW 15 Hz 280 kW 8 Hz 500 kW 5 Hz Cannot be used with motors in parallel Torque regulation mode: Precision 5% Up to +/-300% of nominal torque (Tn)
ATV71 FUNCTIONS Speed controlSVC-I & FVC
ATV71 FUNCTIONS Speed controlSVC-I & FVC
ATV71 FUNCTIONS Speed controlSVC-I & FVC
ATV71 FUNCTIONS Speed controlU/F Volts/Hertz law is simple and robust, doesn’t contain speed loop, slip and IR compensation 2 profiles possible: U/F 2 points and U/F 5 points Applications: Convenient for applications requiring low dynamic performance or low torque at low speed Typically: - special or unknown motors - high speed motors - motors in parallel (different sizes) - variable number of motors, switched on the fly - single phase motors - motors powered through a transformer - tests on small motors
ATV71 FUNCTIONS Speed controlU/F Volts/Hertz law is simple and robust, doesn’t contain speed loop, slip and IR compensation 2 profiles possible: U/F 2 points and U/F 5 points Applications: Convenient for applications requiring low dynamic performance or low torque at low speed Typically: - special or unknown motors - high speed motors - motors in parallel (different sizes) - variable number of motors, switched on the fly - single phase motors - motors powered through a transformer - tests on small motors
ATV71 FUNCTIONS Speed controlU/F Performance: The voltage at the origin and the V/Hz profile are adjustable Maximum frequency of 1600Hz (up to 37kW) Speed precision = nominal slip Nominal torque starting from 5Hz A solution for testing equipment with reduced performance. Possible to control motors 10 times smaller than nominal power U UNS U0 FRS F
ATV71 FUNCTIONS Speed controlU/F 5 points U1:F1 to U5:F5 allows adaptation of the V/F profile to the torque profile of the load For example, can avoid resonance phenomena with high speed motors
ATV71 FUNCTIONS Speed controlU/F
ATV71 FUNCTIONS Speed controlU/F
ATV71 FUNCTIONS Torque control
ATV71 FUNCTIONS Torque control
ATV71 FUNCTIONS Torque control
ATV71 FUNCTIONS Torque control • A speed range around the reference is adjustable (DBP, DBN). • Between these limits the drive is commanded in torque control • If a level is attained, the drive limits the speed
ATV71 FUNCTIONS Current / Torque limitation • The levels of current limit are adjustable • CLI current limit • CLI2 2nd current limit (activated by CLF=LIx) • SSB allows specific actions to occur in case of limitation (current or torque) • no -> no detection • alarm -> display + output assigned to STA • fault -> limitation fault SSF • ST0 sets the current or torque limit time (before the action specified by SSB) • By default CLI is set to 150% In drive, • it is possible to increase it up to 165%
ATV71 FUNCTIONS Current / Torque limitation
ATV71 FUNCTIONS Current / Torque limitation • The torque limit levels are adjustable (+/-300%) • TLIM limitation of motoring torque • TLIG limitation of generating torque • TAI= AIx limitation of torque by analog input
ATV71 FUNCTIONS PID regulator
ATV71 FUNCTIONS PID regulator
ATV71 FUNCTIONS PID regulator