1 / 17

Cost 286 Workshop on „ EMC Aspects of Wireless Communications in Transport Systems”

Cost 286 Workshop on „ EMC Aspects of Wireless Communications in Transport Systems”. Analysis of Leaky Section Cables for Multi-Band Aircraft Cabin Communications with different Measurement Techniques Sven Fisahn 1 , Michael Camp 1 , Núria Riera Díaz 2 , Robert Kebel 3 , Heyno Garbe 1

kayo
Download Presentation

Cost 286 Workshop on „ EMC Aspects of Wireless Communications in Transport Systems”

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cost 286 Workshop on„EMC Aspects of Wireless Communications in Transport Systems” Analysis of Leaky Section Cables for Multi-Band Aircraft Cabin Communications with different Measurement Techniques Sven Fisahn1, Michael Camp1, Núria Riera Díaz2, Robert Kebel3, Heyno Garbe1 1Institut für Grundlagen der Elektrotechnik und Messtechnik, Universität Hannover 2 Institut für Kommunikation und Navigation, Deutsches Zentrum für Luft- und Raumfahrt 3 Lightning Protection and Electromagnetic Compatibility, Airbus Deutschland GmbH e-mail: fisahn@ieee.org

  2. Analysis of LSC by Measurement • Leaky Section Cable (LSC) • Measurement Setup • Open Area Test Site (OATS) • GTEM Cell Measurement • Near Field Scanning • Attenuation Measurement • Measurement Results • Transient Signal (Near Field Scanning, Attenuation) • CW-Signal (OATS, GTEM Cell, Attenuation) • Summary

  3. leaky section non-leaky section Leaky Section Cable (LSC) • Enable use of portable electronic devices (PEDs) inside cabin (e.g. laptops, mobile phones) • Antennas for multi-band aircraft cabin communications (e.g. WLAN, GSM, UMTS, DECT X2X) required • LSC functions both as a transmission line and as an antenna • System integration process requires detailed information about radiation and transmission behaviour and interference potential

  4. Measurement Setup (Open Area Test Site) DLR test site in Oberpfaffenhofen (Germany) • Circular far field radiation pattern • Vertical and horizontal polarization • CW-signals (700 MHz to 2.5 GHz)

  5. Measurement Setup (GTEM Cell Measurement) GTEM 1250 at GEM, University of Hannover • Circular near field radition pattern • CW-signals (450 MHz to 6 GHz) • cable length 1 m, includes 1 leaky section

  6. Measurement Setup (Near Field Scanning) Near field measurements at GEM, University of Hannover • Distribution of electric field strength along the cable  CW-signals (450 MHz to 6 GHz) • Radiation at front side and back side of LSC  Transient signals (rise time: 5 ns) • Conical and biconical field probes

  7. Measurement Setup (Attenuation) Attenuation measurement at GEM, University of Hannover • Transmission behaviour • CW-signals (450 MHz to 6 GHz) • Measurement setup • Cable is unrolled and positioned on the concrete floor of the laboratory • Scattering parameter S21(transfer function of the cable and the connectors at each end)

  8. U / V U / V Test pulse at input of leaky cable Test pulse at output of leaky cable t / s t / s Measurement Results (Transient Signal) Transmission measurement • Fast transient pulses (rise time 5 ns) with double exponential character (cable length 10 m) • Pulse shape nearly identical, merely amplitude damped

  9. |U(j)| / (V/m/Hz) Spectral energy distribution Input(---- blue) Output(---- red) f / Hz Measurement Results (Transient Signal) Comparison of the spectral energy distribution • Identical characteristics of both spectra • Pulse shape nearly unaffected by transmission throughleaky section cable

  10. E(t) / (V/m) Electrical field at leaky side t / s E(t) / (V/m) Electrical field at back side t / s Measurement Results (Transient Signal) Radiation measurement with conical field probe • Electric field strength much higher on leaky side

  11. |E(j)| / (V/m/Hz) |E(j)| / (V/m/Hz) Electrical field at leaky side Electrical field at backside f / Hz f / Hz Measurement Results (Transient Signal) Spectra of radiated electric field • Spectral energy distribution < 1 GHz reduced • Spectral energy distribution > 1 GHz very similar • Discrete frequencies (75 MHz, 150 MHz, 225 MHz,...)

  12. Measurement Results (CW-Signal, OATS) Circular radiation pattern via OATS • Four distances d from the cableaxis at 2 GHz • Single and wide main lope for parallel polarization • Zeros at 0 and 180 deg. for perpendicular polarization

  13. Measurement Results (CW-Signal, GTEM Cell) Circular radiation pattern via GTEM Cell measurement • Main lope in lower frequency range < 2 GHz • Radiation zeros occur in upper frequency range

  14. Measurement Results (CW-Signal, GTEM Cell) Circular radiation pattern via GTEM Cell measurement • Linear and normalized scale shows good agreement with OATS measurements in frequency range < 2 GHz

  15. Measurement Results (CW-Signal, NF-Scan) Field distribution along the cable • Field strength along the cable decreases exponentially • High near field values in leaky sections • High attenuation in upper frequency range

  16. Measurement Results (CW-Signal, Attenuation) Attenuation measurement of cable with 35.7 m length • Attenuation of LSC • increases towards higher frequencies • about 12 dB in frequency range < 1 GHz • larger than 50 dB in freq. range > 3.5 GHz

  17. Summary • Motivation for investigations of LSC • Principle build up of leaky section cable (LSC) • Measurement techniques • Open area test site (OATS) • GTEM cell measurement • Near field scanning • Attenuation measurement • Measurement results • Transient signal • CW-signal

More Related