An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Parkside Development Standards Colorado Springs Together Offices Monday, September 24, 2012 Tuesday, September 25, 2012

  2. Building Types Original DP specified which lots were planned to have each of the following building types: A - Ranch B - Bi-Level C - Tri-Level D - Two-Story For rebuilding purposes: The same type of home shown on the DP may be constructed; If a different building type was constructed than was shown on the plan, that non-conforming home may be rebuilt; A building type with a lower height may be built without formal City action; or A building type with a higher roof may be allowed with additional City review and neighborhood notification Basements will not be required or restricted

  3. Building Setbacks Rear Yard Setbacks Adjacent to Flying W Ranch or Champagne – 30 ft. Adjacent to Majestic, Lions Gate, Hot Springs or Mirror Lake – 12 ft. Not adjacent to public streets – 10 ft. Front Yard Setbacks 18 ft. minimum driveway depth from curb* 5 ft. minimum structure setback from property line Side Yard Setbacks 5 ft. (10 ft. separation from adjacent structures) *Certain lots within Filing 5 are allowed a 16 ft. driveway depth

  4. Lot Coverage and Height Maximum lot coverage allowance for the Parkside development is 40%* Lot coverage pertains to the square footage of any structure having a roof or decks that are 8 ft. above grade Maximum height is 30 ft. using non-hillside methodology *Certain lots within Filing 5 are allowed 45%

  5. Patios and Decks Follow existing Codes and regulations: Under 18 in. from grade – may encroach into any front, side or rear setback 18 in. or higher – must meet the setbacks of the zone district Covered decks count toward the lot coverage allowance and are not permitted to encroach into setbacks 18 in.

  6. Questions? • Call or email: • Kyle Campbell, Interim Planning Director • (719) 385-5360 • kcampbell@springsgov.com • Erin McCauley, Planner II at the Land Use Review Division • (719) 385-5369 or • emccauley@springsgov.com