An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CONTENTS • INVERTER K-SERIES • INVERTER Y SINGLE SPLIT (SERIES I & II) • INDOORS • OUTDOORS • INVERTER Y MULTI SPLIT

  2. INVERTER K-SERIES

  3. INVERTER K-SERIES • INDOOR 5WMY10/15 KR

  4. INVERTER K-SERIES • OUTDOOR 5LCY10/15 ER

  5. INVERTER K-SERIES : Features • High EER / COP of 5WMY • ECONO Mode Econo Mode is a function that sets a limit for power consumption. This mode is useful for preventing Circuit breakers from being overloaded by the use of multiple air conditioners and other electrical devices. The function is easily activated from the remote controller by pushing the ECONO button.

  6. INVERTER K-SERIES : Features • 5 Speed Fan motor, • inclusive of Quiet Mode Super Low Speed @ 22 dBA! • Night Set Mode This function prevent excessive cooling or heating for your pleasant sleep.

  7. INVERTER K-SERIES : Features • Indoor Air Quality • Titanium Apatite Photocatalytic • Air Purifying Filter

  8. INVERTER K-SERIES : Features Comfort Airflow Mode “Comfortable Mode” prevents direct airflow to users and reduces discomfort air drafts. When cooling : Flap can be fixed at higher position than the normal cooling operation position. When heating : Flap can be fixed at lower position than the normal heating operation position and warms feet. Comfort Mode 0° fixed Normal Operation 15~45° 0° 15° 5° Comfort Mode 50° fixed Normal Operation 5~45° 45° 50° 45° by one touch ! < Cooling > < Heating >

  9. INVERTER K-SERIES : Features • Standby electricity savingWithout this function, about 6W standby electricity is necessary. By cutting power supply to outdoor unit, necessary standby electricity is reduced to 1 W at the least. This new function corresponds to diversified energy saving needs. Operation standby electricity < Without “Standby Electricity Saving” > < With “Standby Electricity Saving” > 1 W For indoor unit microcomputer 1 W For indoor unit microcomputer 5 W For outdoor unit microcomputer 0 W (Outdoor unit is suspended) Note: In some conditions, for example when temperature is low, outdoor unit runs microcomputer and preheats compressor and thus uses energy. (About 35 W is necessary for preheating)

  10. INVERTER Y SINGLE SPLIT

  11. INVERTER Y SINGLE SPLIT Product Line Up 5CMY-ER 5CCY-CR 5WMY-JR 5CKY-ER 5CKY-CR SERIES I SERIES II

  12. SERIES I

  13. SERIES I • Indoor: 5WMY-JR 5WMY 10/15/20/25JR

  14. SERIES I • High EER/COP performance. • ALL Models rank A/A or Exceeds! WMY-J Features: • High Quality & Efficiency Daikin DC Inverter compressor • High Performance Daikin Inverter Controller • 5-speed Step-less Fan operation • BioPro IAQ. • New Inverter-only Remote Control

  15. SERIES I • Indoor: 5CKY-CR 5CKY 10/15/20CR

  16. SERIES I • Outdoor: 5LCY-DR 5LCY 10/15DR

  17. SERIES I • Outdoor: 5LCY-CR 5LCY 20/25CR

  18. SERIES I Outlook About the same between 5LCY & 5LCX-series 5LCY10/15D Series 5LCX-C Series * 5LCY20/25 will be using the same casing as 5LCX and mass-production by March 2010

  19. SERIES I Piping Length & Elevation

  20. SERIES I Control Box • Control box casing using plastic material. • Reactor is mounted on outdoor panels. • Control box is mounted face down. 5LCX-C 5LCY-D Compact & Lighter

  21. SERIES I Terminal Block • Equipped with 7-segment display to improve serviceability. • To retrieve error code & running parameters.

  22. SERIES I Thermistors Heat sink thermistor to capture heat sink temperature

  23. SERIES I Outdoor Fan • Both Y-series and X-series are using variable OD fan speed control by ON/OFF cycle motor. • Variable speed duty cycle in respond to current system load & ambient condition.

  24. SERIES I Software and Protection

  25. SERIES I Control System Compatibility * Standard handset for CC units, not available yet for wall mounted series.

  26. SERIES II

  27. SERIES II • Indoor: 5CKY-ER 5CKY 28/40/50ER

  28. SERIES II • Improve Sound Level • New CKY-E series is equipped with a newly-developed turbo fan, which has improved the sound pressure level of the unit significantly. • 4 selected fan speeds • By selecting the Quiet mode, the sound pressure level can be as low as 27dBA. 5CKY-ER Features

  29. SERIES II • Multi comfort- 3 air swing pattern control • 3 selected air swing pattern to suit different requirements 5CKY-ER Features Swing mode selection method through wireless handset: • Press SWING button for 4 seconds to enter field setting mode. While in field setting mode, show only SETTING MODE • Press temperature + or – button to select SWING MODE rotation from SWING MODE 1 to SWING MODE 3 • If no mode changes within 4 seconds, unit will operate according to the selected SWING MODE

  30. SERIES II • Optimum Air Discharge • Combining 4 ways air discharge and large discharge area on each side • Additional of the automatic air swing help to further to evenly distribute conditioned air to every corner of the install area. 5CKY-ER Features

  31. SERIES II Allow 90°Rotation • Modern & Elegant Panel Design • Unique “Round” side contour • Side LED light location • Promote Uniform Installation • Same dimension (all capacity) • Rotate able intake grill 5CKY-ER Features

  32. SERIES II A B C • Lower Height model 5CKY-ER Features • 2 uniform height base on different capacity • Small fan motor • Compact body design

  33. SERIES II • Built-In high head drain pump 5CKY-ER Features • Built-in high head drain pump 700mm head. • A safety float is incorporated in the drain pump to monitor its water level

  34. SERIES II • Indoor: 5CMY-ER 5CMY 28/40/50ER 5CMY 62CR

  35. SERIES II • Ceiling and floor installation option 5CMY-ER Features • To install below the ceiling • To mount at low wall position Ceiling installation type • Easy Serviceability - Control box, motor and blower can be access easily by just pulling down the filter rail. Standing installation type

  36. SERIES II • Negative ion generator 5CMY-ER Features • To increase the amount of negative ion in the air conditioning area, creating more refreshing environment • Automatic air swing • The motorized louver enables the air flow to be evenly distributed. • At the same time, negative ion will be released to provide quality air

  37. SERIES II • Flexible installation 5CMY-ER Features • Unit is designed to work with high pressure head drain pump (optional). • To offer flexibility for installation on condensate drain pipe • Drain pump comes with a high head and is incorporate with the float switch as safety protection

  38. SERIES II • Fresh air option 5CMY-ER Features -The unit is designed to draw in fresh air from outdoor. A fresh air knocked out holes is designed within the unit itself to provide better ventilation.

  39. SERIES II • Indoor: 5CCY-CR 5CCY 28/38/50/60CR

  40. SERIES II • Microprocessor controlled 5CCY-CR Features • Offer comfortable room conditions according to the needs of the user • Provide protection to components of the air conditioning unit against any fault through its control algorithm • Optional duct accessories * Available for 5CCY10-25CR only.

  41. SERIES II • Auto random restart 5CCY-CR Features • Automatically restart according to the last state setting condition when power resumed • Option is provided to cancel this features • Double protection drainage system • Primary drain pan: high thermal insulation material and molded in gradient for better condensate water drainage • Secondary drain pan: “built in” to standard unit offers extra protection against possible water leaking problems

  42. SERIES II • Outdoor: 5LCY-ER 5LCY 30/40/50/60ER

  43. SERIES II Piping Length & Elevation

  44. SERIES II Control Box • Control box is vertically mounted facing out of the casing. Main & inverter PCB

  45. SERIES II Others

  46. SERIES II Control System Compatibility * Standard handset for CC units, not available yet for wall mounted series.

  47. INVERTER Y MULTI SPLIT

  48. INVERTER Y MULTI SPLIT Outdoor Unit Indoor Unit 5WMY-JR 5MSY20/25/30BR 5CKY-ER 5CKY-CR 5CCY-CR 5CMY-ER

  49. INVERTER Y MULTI SPLIT • 5MSY-BR Features • Flexibility in Application & Installation • Available for double, triple, and quadruple indoor connections. • Different types of indoor units in the same system. • Better Energy Saving • Combination of improved efficiency compressor and intelligent electronic controls. • Achieved class A/A based on European Energy Efficiency Class ratings.

  50. INVERTER Y MULTI SPLIT Outlook About the same between 5MSY & 5MSX-series 5MSY-B Series 5MSX-A Series