1 / 25

The TC: status. Flavio Gatti UNIVERSITY and INFN of Genoa, Italy

The TC: status. Flavio Gatti UNIVERSITY and INFN of Genoa, Italy. TC design review vs. DC and N2-Bag. Nitrogen Bag Not shown. Scintillating Fibers. Preamplifiers and cables. From COBRA center. 105 cm. 25 cm. 8.5 º. 19 º. 22 º. 11 º. B. B. Timing Counter: final desing review.

keita
Download Presentation

The TC: status. Flavio Gatti UNIVERSITY and INFN of Genoa, Italy

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The TC:status.Flavio GattiUNIVERSITY and INFNof Genoa, Italy

  2. TC design review vs. DC and N2-Bag Nitrogen Bag Not shown Scintillating Fibers Preamplifiers and cables

  3. From COBRA center 105 cm 25 cm 8.5º 19º 22º 11º B B Timing Counter: final desing review Scintillator Slab ☺ 20°rotation increase response uniformity and timing performance achievable by using the coincidences ☺ Positron Path-Length (5 cm)enough for the required Timing Res. ☺ Maximal Matching Scintillator-PM -> Note: cut of upper edge(5mm in radial direction in order to avoid TC-D.C. contact -> lower edge is also cut away in order to have symmetrical shape ☺ Optimal compromise between PM field gain suppression factor availabe space. PM tilted of ~20º respect to the Mag.Field, ~10º respect to the axis 5mm Scintillator Cross Section 5mm PM active diameter: 39 mm Sectional view PM outer Diameter :52 mm 0.75 T 1.05 T Long. view

  4. Re-shaped Scintillating Slab Curved Scintillating Fiber Scintillating Slab Hollow adapter and Slab black cover

  5. Comparison of MEG TC with other timing detectors • MEG TC 4x4x90 BC404 R5924 270 38 Table form E.Nappi / Bari

  6. TC Final Design • A PLASTIC SUPPORT STRUCTURE ARRANGES THE SCINTILLATOR BARS AS REQUESTED • THE BARS ARE GLUED ONTO THE SUPPORT • INTERFACE ELEMENTS ARE GLUED ONTO THE BARS AND SUPPORT THE FIBRES • FIBRES ARE GLUED AS WELL • TEMPORARY ALUMINIUM BEAMS ARE USED TO HANDLE THE DETECTOR DURING INSTALLATION • PTFE SLIDERS WILL ENSURE A SMOOTH MOTION ALONG THE RAILS

  7. • PMTs ARE ATTACHED, BY MEANS OF THE INTERFACE SOCKET, TO THESCINTILLATOR BARS • GIVEN THE MASS, AN ELASTIC AND REMOVABLE SILICONE GLUE IS APPROPRIATE • THE HOLLOW INTERFACE ELEMENT IS A “CUSTOMDESIGNED” PROFILE THAT ADDS A MINIMUM AMOUNT OF MATERIAL BETWEEN THE FIBRES AND THE BARS • SLOT FOR CABLES and OPTICAL FIBERS HAVE BEEN FORESEEN TO ALLOW THE CABLES FROM THE INNER PMT TO EXIT

  8. Under construction:PMT socket (beloW), hollow\interface and plastics bars

  9. Copper block APD Splitters Pulsed Laser Peltier Cell 1/1000 attenuator Integrating Calibrated Photometer Fast Photodiode Photomultiplier Curved TC (trigger & pattern):APD test system A batch of not irradiated about 1100 APDs has been received in April. These are under test for selection and binning (grouping APDs with same V-breakdown). The test set-up allow automatic data acquisition by using pulsed laser response.

  10. Curved detector: APD test system

  11. APD0210117506_20ID_M APD0107115426_20ID_M APD8411087442_20ID_M APD8418088162_20ID_M dark vs H.V. Temperature 20°C APD8223084713_20ID_M I APD8201082393_20ID_M APD1910145247_20ID_M APD8024081013_20ID_M 1.00E+01 APD8007079173_20ID_M APD791478311_20ID_M APD1908145087_20ID_M APD1905144927_20ID_M APD1906145007_20ID_M APD1909145167_20ID_M APD1913145407_20ID_M APD1902144767_20ID_M APD1903144847_20ID_M APD1911145327_20ID_M APD8206082873_20ID_M 1.00E+00 APD1222134415_20ID_M APD1212133615_20ID_M APD1211133535_20ID_M APD1213133695_20ID_M APD1218134175_20ID_M APD8710092535_20ID_M APD8810094569_20ID_M APD8822095449_20ID_M APD8709092455_20ID_M I Dark @ 10Mohm (Volts) APD8722093575_20ID_M APD8711092615_20ID_M 1.00E-01 APD8811094649_20ID_M APD8619091391_20ID_M APD8601089791_20ID_M APD1512138823_20ID_M APD1511138743_20ID_M APD1822144554_20ID_M APD1812143994_20ID_M APD1704141813_20ID_M APD1720142933_20ID_M APD1613140756_20ID_M APD1611140596_20ID_M 1.00E-02 APD1612140676_20ID_M APD1616140996_20ID_M APDJA0296_20ID_M APDJA0302_20ID_M APDJA0288_20ID_M APDJA0307_20ID_M APDJA0312_20ID_M APDJA0308_20ID_M APDJA0309_20ID_M APDJA0311_20ID_M APDJA0295_20ID_M 1.00E-03 APDJA0289_20ID_M APDJa0290_20ID_M 2.50E+02 3.00E+02 3.50E+02 4.00E+02 4.50E+02 5.00E+02 APDJA0292_20ID_M APDJA0294_20ID_M APDJA0316_20ID_M H.V. (Volts) APDJA0304_20ID_M APDJA0305_20ID_M APD comparison: PSI(blue), new Hamamatsu (red) I = 50 nA

  12. Kapton Flex. APD Black Coating Electronics boards -10 channels Scint. Fibers Transition board Copper Cold Finger(~20°) Peltier Cell Heat Exchanger APD set-up: conceptual design APD even and odd interleaved, FRONT VIEW: To be connected to the fibers SIDE VIEW with fiber, electronics, cooler

  13. APD read-out: final design

  14. 5x5 mm scint. Fiber APD readout MC of the curved TC • L.Y.=8000 ph/Mev • Trap eff.= 7% • APD gain = 500 min. • Q ~ 1.5x10^5 • Detect. eff. ~ 98%

  15. APD Preamplifier • ENC: 1500 e rms; Risetime:5 ns; Pulse-length: 50 ns

  16. Banch test of the APDs Preamplifier Test pulser Output 1V/ pC 5.5 ns risetime

  17. From TC right side From TC left side 152 152 A*B A B 152 Mask A Mask B Clock, control signal, etc. Control Logic Encoder To Trigger and monitor To VME bus Register Encoding the hit pattern

  18. To be defined soon: • Definition of the supporting structure and construction (july) • Insert APD read-out system in the final design (july) • APD amplifier PCB and production (end of sept.) • Validation test at BTF (LNF) of 10 elements of curved detectors(sept.) (we are undertaking a preliminary test with cosmics) • Final construction of whole TC (sept-nov). • Estimate delivery of the timing counter end of november • Test @ BTF: december Under study (advanced status) • TC bag • TC curved detector: digital pattern generator • TC linear detector: DRS matching electronics

  19. Provisional design of N2 bag

  20. N2 bag inside cobra

  21. Access port on cobra flanges

  22. He Diff. in Plastics Film( cm^3 m^2 )/( atm mm day)

  23. He input in the TC bag for EVAL F : few x 10-5 mbar/day

  24. Attenuator (passive) Inverter + offset 0.15 - 1.7 V To the DRS Passive Splitter To the DRS Fast double Thres. Discr. Shaper + offset 0.15 – 1.7 V 20 MHz reference PM1 PM2 T1 Disc 1 T2 Disc 2 How to match the Read-out with DRS?

  25. Summary • Scint Slab (BC404) resolution=91 ps • Timing resolution over the whole length = ±5% Max. • Plastics sizes, shapes and PM coupling works fine. • The solution has been indirectly validate in the COBRA • A test with the matching electronics with DRS in order to verify the readout solutions is foreseen in sept/oct. • Final design has been done and reviewed and the main parts of the TC are under construction ( BC404 slab, plastic black coverage, socket for PM, interface) • TC bag: a prototype design is under study, plastics we have considered EVOH, SARAN (FEP, Nylon 6, TEP Polyamide) • New batch of not irradiate APD have been delivered April. The test is positive ( 90% acceptance) • Electronics for APD. (1) Two solutions: high bandwidth OPA (lower cost-higher noise), integrated charge amplifier( higher cost, lower noise). -->Selected a mixed solution. (2) PCB that groups 8/10 APD (3) encoding with FPGA-VME.

More Related