1 / 6

Entry 1 Entry 2 Entry 3

N. ventilation shaft. TEAM MAP. warehouse. D. CX 3. shop. CX 2. CX 1. C. Entry 1 Entry 2 Entry 3. N. D. ramp (8% downgrade). PROBLEM MAP. spare vent bag and installation / repair tools. barricade. ventilation shaft.

Download Presentation

Entry 1 Entry 2 Entry 3

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. N ventilation shaft TEAM MAP warehouse D CX 3 shop CX 2 CX 1 C Entry 1 Entry 2 Entry 3

  2. N D ramp (8% downgrade) PROBLEM MAP spare vent bag and installation / repair tools barricade ventilation shaft water over knee deep warehouse electric water pump & pump controls water knee deep shop fan shop water ankle deep CX 3 shop fan control 2 sets of brattices CX 2 vent tubing vent bag auxiliary fan 1 set of brattices CX 1 C auxiliary fan controls caved air tight fresh air base Entry 1 Entry 2 Entry 3

  3. D 1st VENT CHANGE MAP barricade ventilation shaft warehouse shop fan CX 3 CX 2 vent tubing CX 1 convert check curtain to temporary stopping caved air tight fresh air base Entry 1 Entry 2 Entry 3

  4. D 2nd VENT CHANGE MAP barricade ventilation shaft warehouse shop fan CX 3 extra vent bag and tools retrieved from warehouse; vent bag repaired CX 2 vent tubing CX 1 caved air tight fresh air base Entry 1 Entry 2 Entry 3

  5. PLACARD MAP 28 28a barricade 17 18 16 32 15 27 14 31 26 CX 3 30 13 34 33 29 12 25 11 10 35 CX 2 36 23 9 24 37 8 7 6 check curtain 38 CX 1 5 39 22 20 4 21 40 3 19 41 2 1 Entry 1 Entry 2 Entry 3

  6. Placard Key • Fresh air base • Caved air tight • Caved air tight • Controls for auxiliary fan • O2=19%, CH4=0, CO=2,500 ppm, NO2=5 ppm, Light smoke, (2-sided - - CLEAR AIR) • Auxiliary fan • Vent bag • Haul truck • O2=14%, CH4=0, CO=8,000 ppm, NO2=20 ppm, Heavy smoke(2-sided - - CLEAR AIR) • Ramp, 8% downgrade, down in this direction • Loader on fire (2 sided - - FIRE OUT) • 20 feet of vent bag burned and missing completely • Water ankle deep (2 sided - - blank on the back side) • Water knee deep (2 sided - - blank on the back side) • Electric water pump and pump controls • Water over knee deep (2-sided - - WATER ANKLE DEEP) • O2=14%, CH4=0, CO=8,000 ppm, NO2=20 ppm, Heavy smoke (2-sided - - CLEAR AIR) • Barricade 7’x10’ • Face drill • Check curtain • Check curtain • O2=16%, CH4=0, CO=5,000 ppm, NO2=15 ppm, Heavy smoke (2-sided - - CLEAR AIR) • O2=15%, CH4=0, CO=6,000 ppm, NO2=10 ppm, Heavy smoke (2-sided - - CLEAR AIR) • Loader • Haulage truck • O2=16%, CH4=0, CO=5,000 ppm, NO2=15 ppm, Heavy smoke (2-sided - - CLEAR AIR) • Permanent stopping with door • 20 foot section of vent bag (also 28a Use tape to repair vent bag) • Permanent stopping • Controls for shop fan • Shop fan, airflow in this direction • Ventilation shaft • Permanent stopping • O2=19%, CH4=0, CO=2,500 ppm, NO2=5 ppm, Light smoke (2-sided - - CLEAR AIR) • Brattice materials (2 sets) • O2=19%, CH4=0, CO=2,000 ppm, NO2=5 ppm, Light smoke (2-sided - - CLEAR AIR) • Scaler • Brattice materials (1 set) • O2=20%, CH4=0, CO=1,000 ppm, NO2=0, Light smoke (2-sided - - CLEAR AIR) • Haulage truck • Clear air

More Related