1 / 8

Future Facilities and nlyte Software Provide Fully Integrated DCIM and CFD Software Solution

Future Facilities and nlyte Software Provide Fully Integrated DCIM and CFD Software Solution. &. Integrated nlyte and 6SigmaFM enables engineering and IT operations to manage the data center as a team. Operations. Facilities. Any plans made in nlyte can be simulated in 6SigmaFM . Space.

kesia
Download Presentation

Future Facilities and nlyte Software Provide Fully Integrated DCIM and CFD Software Solution

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Future Facilities and nlyte Software Provide Fully Integrated DCIM and CFD Software Solution &

  2. Integrated nlyte and 6SigmaFM enables engineering and IT operations to manage the data center as a team Operations Facilities • Any plans made in nlyte can be simulated in 6SigmaFM. Space Power nlyte 6SigmaFM Engineering Simulation Network Cooling • The consequences of the deployment are fed back into nlyte before deployment.

  3. Overview: Recent developments in data centre managementsoftware Await thermal outcome,troubleshoot reactively

  4. 1) Traditional Approach to provisioning(without nlyte or 6SigmaFM) Operations Facilities Check cabinet availability independently Cooling Network Space Power Change Management Process    ? Report Report Report Report  Await thermal outcome,troubleshoot reactively Space, Power and Network availability are checked independently in provisioning process, cooling not checked at all.

  5. 2) DCIM and CFD used independently Operations Facilities DCIM CFD Space Power Network Change Management Process  Report  Await thermal outcome,troubleshoot reactively Report Engineering Simulation  DCIM streamlines provisioning process and provides capacity management CFD enables airflow and cooling management but it is done retrospectively

  6. 3) Integrated DCIM and Simulation Operations Facilities nlyte 6SigmaFM Engineering Simulation Network Space Power Cooling Change Management Process   Report Report Process CompleteMove on

  7. Typical process using integrated nlyte and 6SigmaFM  • Typical everyday Process: • Deployment Within Limits • More Flexibility: • Pushing the Limits • Understanding Consequences: • Resetting Cooling Limits nlyte 6SigmaFM nlyte 6SigmaFM nlyte 6SigmaFM   • The cooling limits set by CFD simulation are available in nlyte to be used in management and planning. Engineering does not need to be involved directly in provisioning, but nlyte gets the benefits of CFD simulation. • Flexibility to plan Move, Add or Change knowing that it that will break cooling limits. Engineering simulation is used to find a solution that meets IT cooling requirements and operational objectives. IT equipment changes alter cooling limits because they effect airflow patterns and local temperatures. Engineering simulation continually updates cabinet cooling limits so nlyte users work with the latest cooling information.

  8. Snapshots of the integrated process Moves, Adds and Changes deployment plans nlyte 6SigmaFM CFD Simulation updated cooling limits