440 likes | 536 Views
A primer course of experimental particle and nuclear physics . BiPo decay experiment. Tran Duy Tap Le Cong Hao Doan Thi Hien (Nomachi group). OSAKA UNIVERSITY - 2009. OUTLINE. Introduction Principle of measurement Results Summary. Introduction (1). BiPo decay experiment
E N D
A primer course of experimental particle and nuclear physics BiPo decay experiment Tran Duy Tap Le Cong Hao Doan Thi Hien (Nomachi group) OSAKA UNIVERSITY - 2009
OUTLINE • Introduction • Principle of • measurement • Results • Summary
Introduction (1) • BiPo decay experiment • Set up the CAMAC and FADC to measure the BiPo decay • Principle of measurement • Time and energy calibrations • Measurement of T1/2 of BiPo decay • Measurement of beta and alpha energy of BiPo events • Measure amount of BiPo decay
Q = 2.2 MeV Long -life Short -life Material to make BiPo detector is called Yunohana powder which contains BiPo decay • Long –life: measured by FDAC • Sort – life: measured by FDAC and CAMAC Introduction (2) Purpose of the BiPo decay experiment is to measure the contamination in 208Tl and 214Bi of the source foils which are used for double beta decay experiment.
Principle of measurement (1) Yunohana is placed as sandwich of two PMTs Time signature: 1 hit and 1 delay hit PMT A Time PMT B Yunohana Paper Yunohana Yunohana is faced to PMT B only, so PMT A only gets electron signal PMT A PMT B Grease Grease Plastic
Principle of measurement (2) Schematic of data acquisition ADC ADC1 ADC2 PMT A Delay Devider Discrimator Gate Paper Energy measurement A Yunohana TDC Start Stop Devider B Delay Time measurement Discrimator PMT B
Principle of measurement (3) Time and energy measurement PMT A Time PMT B Time measurement by (TDC) Time difference Stop logic Start logic Gate 700 ns Energy measurement by (ADC)
Principle of measurement (4) Set up of the measurement Thickness lead and copper to reduce the background PMT B PMT A • Thickness of lead is 10 cm • Thickness of copper is 5 cm
Principle of measurement (5) NIM CAMAC ADC Scaler TDC Delay Discriminator Time range of TDC: 700 ns
Time calibration (1) • Time calibration is to determine delayed time between two sequence events between two PMTs. • Function generator is used to generate two known delayed-time pulses. DAQ Ch 1 TDC Function Generator Start Stop Ch 2 Time diff.
Time calibration (2) Result of time calibration 1 ch = 20.85 ns
Energy calibration (1) Measuring gamma + beta Measuring gamma Pb collimator Plastic scintillator Pb board Plastic scintillator 207Bi source 207Bi source Gamma ray Beta ray Gamma ray
Energy calibration (2) Energy calibration of PMT A • Red line is gamma spectrum • Black line is gamma-beta spectrum Region difference Gamma-beta spectrum 976 keV Beta spectrum Gamma spectrum
Energy calibration (3) PMTA: • Energy of beta: 976 keV • Channel: 240 4.07 keV/ch Similar, PMTB: 3.75 keV/ch
Results (1) Time measurement by TDC Coincidences Single hit BiPo events • Time to measure is 37.5 h • Counts to get are 51073 • Count rate is 0,378 counts/second Coincidences almost from cosmic ray
Results (2) Time PMT A BiPo events PMT B Time PMT A Coincidence PMT B PMT A Time Single hit PMT B
Fitting data as follows: Results (3)
Results (4) Time measurement by TDC Linear fit of the BiPo decay Linear Fit Y = A + B * X Parameter Value Error ----------------------------------------------------- A 2,98279 0,1213 B -0,00249 3,39504E-4
Results (5) • Time to measure is 37.5 h • Counts to get are 51073 • Count rate is 0,378 • BiPo events are 429 • BiPo count rate is 0,003 counts/second
Results (6) Energy measurement by ADC Beta 2200 keV Alpha • Quenching factor = 1/11 • 8 MeV@ = 0.8 MeV@e- 800 keV
Summary • What we do: • Set up the detection of BiPo events • Set up data acquisition using NIM and CAMAC • Measure the half-life of BiPo soft – life decay • Measure the beta and alpha energy of BiPo decay • Measure amount of BiPo sort-life decay • What we feel: • NIM and CAMAC can measure the sort-life of BiPo decay • TDC is actual useful to measure the time difference between beta and alpha signatures • We can learn how to make the logic trigger • NIM and CAMAC in this experiment can’t measure the long-life of BiPo decay due to the limitation of equipment. (time range 700 ns)
BiPo detectorwith FADC Le Cong Hao
ADC or TDC FADC Why FADC? We will lose some signal Losing signal By using FADC we will not worry much about it
( 164 µs ) Main background Short life Long life
Plastic Scintillator α b Understanding of signal collected processing Short life
Pb 2. Energy calibration PL Gamma spectrum +g +g g e e Bi 207 Beta + Gamma spectrum
976 Kev After subtract and gauss fitting
758.7 channel = 976 Kev After subtraction and gauss fitting
910.4 channel = 976 Kev After subtraction and gauss fitting
3. Taking data for Bipo events • Time for taking data: 9h • Number of events: 30000 • visual scaler: 30302
After taking data, we use “Ana” program (Nomachi’s group) and “Paw” (Cern) software for the analysis Bipo events In this experiment we can measure Long and Short Bi-Po events
~700 Kev ~3.27 Mev ~800 Kev ~2.25 Mev
LongBBtimed 164 us LongABtimed 164 us ShortBBtimed 164 us ShortABtimed 300 ns
Disadvantge There are also some present problems for FADC: • Data size is too large • Event selection maybe can’t be done until data are copied to CPU memory • Some impossibe for saving all triggered data
Conculsions • By using FADC we can observe exactly both long and haft life in Bi Po source that is limited by NIM & CAMAC • In fact, FADC is the most future choice due to many advantages as presented above
My empression in this training at osaka university: • First of all I want to say your country is very beatiful and the people is very kindly • Secondly, the background from this training is very useful for me when I come back to Viet Nam and I hope to have another chance to come back here for cooporation with you in near fultuer University of Natural Sciences Faculty of Physics Department of Nuclear Physics 227 Nguyen Van Cu Street, 5 Dictrict, Ho Chi Minh City, VietNam www.hcmuns.edu.vn Le Cong Hao Email:lchao@phys.hcmuns.edu.vn
Thanks to • Prof. Nomachi, Prof. Kishimoto, Prof. Kuno whom are organizers • Dr. Vo Hong Hai • Mr Kouno • Mr kanamaru • Mr Otake
Acknowledgments • Osaka University • Prof. Nomachi Group • JICA • Professors give the lectures • My partners in doing BiPo decay
Thanks for your attention! The end