1 / 32

Modular Inverter

Modular Inverter. Modular Inverter Series UNV. [HF Technology 1st Generation]. UNV-F1.2 - UNV-F1.8 – UNV-F2.5 – UNV-F3.3 – UNV-F5.0. Available input voltages of:. 48V DC. 1200VA(960W) 1800VA(1440W) 2500VA(2000W) 3300VA(2640W) 5000VA(4000W).

ketan
Download Presentation

Modular Inverter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Modular Inverter

  2. ModularInverter Series UNV [HF Technology 1st Generation] UNV-F1.2 - UNV-F1.8 – UNV-F2.5 – UNV-F3.3 – UNV-F5.0 Available input voltages of: 48V DC 1200VA(960W) 1800VA(1440W) 2500VA(2000W) 3300VA(2640W) 5000VA(4000W) 60V DC 110V DC Available output voltages of: 230V AC / 50Hz | --------------------------------------------------------- 19“ x 3U ------------------------------------------------------------ |

  3. Modular Inverter Series UNV UNV-F Technical information Input: Output:230V, 50 or 60Hz (programmable), single phase It is possible to build three phase system, each phase with numbers inverter in parallel. Max. number of inverter working in parallel: 16 pieces

  4. Modular Inverter Series UNV UNV-F Special features >> Electrical isolation between input and output >> Input over/under voltage shutdown >> Hot-plug-in able >> Ready for paralleling (no fixed master) >>Current sharing based on decrease line of max. 1% for the output voltage >> Load balance max +/- 5% INom >> n+x redundancy >>Ability to build three phase systems with a number of inverters per phase >> Output overload and short circuit proof >> Temperature controlled fan cooling (font-to-rear airflow) >>Digital display for output voltage / current and adjustment of internal default settings >> Crest factor < 3 >> Can bus interface for communication with static bypass switch and/or monitoring unit >>Working temperature: -20°C up to +45°C >>Power factor range: 0,5 ind. - 1 – 0,5 cap. >>Ability for stand-alone operation >> Designed to operate together with static bypass switches >>overload capability 130% for 30sec

  5. Modular Inverter Series UNV UNV-F Signalling Relay signalling: Dry contact for common alarm. Contact rating: 8A@250VAC, 8A@30VDC High input voltage Output voltage O.K. Operation Display for output voltage (top line, 3 signs) and output current (second line, 3 signs) flashing: ventilator fault Constant : high internal temperature Common alarm Overload Low input voltage

  6. ModularInverter Series UNV UNV-F Mounting (mounting kit): View into a system (left side) Plugs for inverter UNV-F Slide rails

  7. ModularInverter Series UNV UNV-F Needed / available accessories - mounting kit >> article number: 880-MEC-MKT.01 (except UNV48-5,0F) >> article number: 880-MEC-MKT.02 (only UNV48-5,0F) - socket (standard: part of delivery scope) >> article number: 880-MEC-MKT.21 (except UNV48-5,0F) >> article number: 880-MEC-MKT.22 (only UNV48-5,0F)

  8. ModularInverter Series INV [HF Technology 2nd Generation] Available input voltages of: INV211 - INV216 - INV245x (x=still in development) 24V DC 48V DC 60V DC 1100W(1375VA) 1600W(2000VA) 4500W(5600VA) (24V only) 110V DC 220V DC Available output voltages of: 230V AC / 50Hz |-------------------- 1/4-19“ x 2U ------------------- | ---------------------- 19“ x 2U ------------------------- |

  9. Modular Inverter Series INV INV 222 (INV215@24VDC) Technical information Input: Output:230V, 50Hz, single phase Max. number of inverter working in parallel: 8 pieces

  10. Modular Inverter Series INV INV INV 222 (INV215@24VDC) Technical information Signalling: Operation: input voltage within nominal value Output voltage within nominal value Common alarm Remote signalling: Dry contact for common alarm. Contact rating 60V/0,1A

  11. Modular Inverter Series INV INV 222 (INV215@24VDC) Special features >> Electrical isolation between input and output >> Input over/under voltage shutdown >> Hot-plug-in able >> Ready for paralleling (no fixed master) >>Current sharing based on decrease line of max. 1% for the output voltage >> Load balance max +/- 10% INom >> n+x redundancy >> Output overload and short circuit proof >> Temperature controlled fan cooling (font-to-rear airflow) >> Crest factor < 3 >> Can bus interface for communication with static bypass switch and/or monitoring unit >>Working temperature: -20°C up to +55°C >>Power factor range: 0,5 ind. - 1 – 0,5 cap. >> Designed to operate together with static bypass switches >> Overload capability 130% for 5sec; 110% for 1min

  12. ModularInverter Series INV INV INV 222 (INV215@24VDC) Mounting: Front view of 19” rack Mounting angles Static bypass switch STS207 Three slots for inverter INV222

  13. ModularInverter Series INV216 INV INV 222 Needed / available accessories >> 19” rack, 2 HU, including backplane for 3x inverter + 1x STS >> article number: 502-222-315.LV (for DC input 24-60V) >> article number: 502-222-315.HV (for DC input 108-216V) >> 19” rack, 2HU, with backplane for 4x inverter (without STS) >> article number: 502-222-405.LV (for nominal DC voltages 24-60V) >> article number: 502-222-405.HV (for nominal DC voltages 108-216V) >> Cover plates to cover not used inverter slot, 2HU, RAL7035 >> article number: 881-MEC-BPL.02.21.B

  14. ModularInverter Series PWS PWS-1.0 - PWS-2.5 - PWS-5.0 Available input voltages of: 24V DC 1000VA(800W) 1800VA(1440W) 2500VA(2000W) 3300VA(2640W) 5000VA(4000W) 110V DC 220V DC Available output voltages of: 230V AC / 50Hz Other voltages / frequencies on request Available mechanical design: 19” 4/5U or wall cabinet

  15. Modular Inverter Series PWS PWS Technical information Input: Output:230V, 50 single phase It is possible to get special output voltages / frequencies Max. number of inverter working in parallel: 12 pieces

  16. Modular Inverter Series PWS PWS Special features >> Electrical isolation between input and output >> Input over/under voltage shutdown >>Available as 19” rack or as wall cabinet >> Ready for paralleling (no fixed master) >>Current sharing based on decrease line of max. 1% for the output voltage >> Load balance max +/- 10% INom >> n+x redundancy >> Crest factor < 2,5 >> Output overload and short circuit proof >> Temperature controlled fan cooling (font-to-rear airflow) >>Overload capability 160% for 1min; 130% for 10min >> Special output voltages / frequencies on request >>Working temperature: -20°C up to +45°C >>Power factor range: 0 ind. - 1 – 0 cap. >>Analogue measurement instruments for output voltage / current >>Ability for stand-alone operation >> Designed to operate together with static bypass switches

  17. Modular Inverter Series PWS PWS Signalling Relay signalling: Dry contact for common alarm. Contact rating: 5A@250VAC, 5A@30VDC High input voltage Output voltage O.K. Operation High internal temperature Common alarm Failure Low input voltage

  18. ModularInverter Series PWS PWS Needed / available accessories - mounting kit >> article number: 880-MEC-MKT.03

  19. Modular Static Switches

  20. Modular Static Switches Series STS STS207 - STS114 - STS230 - STS350 still in development still in development still in development 7kVA@230V AC 14.5kVA@230V AC 30kVA@230V AC 50kVA(1/3phase) |---- 1/4-19“ x 2U ---- | ------------------ 19“ x 1U ------------------ | ---------------------------------------------- 19“ x 3U -------------------------------------------- |

  21. Modular Static Switches Series STS STS Technical information Input: - Special versions for nominal input voltage of 24-60VDC and 108-216VDC. - 1x 230VAC bypass mains - 1x 230VAC inverter output Output: - 1x 230VAC, in phase with bypass input

  22. Modular Static Switches Series STS STS Signalling Remote signalling: Optocoupler for common alarm, Relay on backplane: Max. contact rating: 30W / 50VA; 60VDC / 125VAC; 1ADC / 1AAC Load on Inverter Bypass input Load on Mains Inverter input Operation Display of 4 lines Synchron bus in phase with bypass mains input Common alarm Ethernet Interface CAN-bus Interface

  23. Modular Static Switches Series STS STS Special features >> Hot-plug-in able >>Display for all main operating parameters, settings and measuring values >> Ethernet interface for remote connection via SNMP protocol or WEB-Browser >> Minimized synchronisation time (because of digital PLL) >> It is possible to use diesel gensets as bypass mains >> Transfer time < 4ms >> Monitoring of both incoming sources according to voltage level, frequency and synchronisation >> Temperature controlled fan cooling (font-to-rear airflow) >>Free programmable operation mode (inverter priority or bypass priority) >> Overload capability 1000% for 10ms >> CAN bus interface

  24. Modular Static Switches Series STS STS Needed / available accessories >> 19” rack, 2 HU, including backplane for 3x inverter + 1x STS >> article number: 502-216-315.LV (for DC input 24-60V) >> article number: 502-216-315.HV (for DC input 110-220V) >> Manual bypass switches (recommended by ELTEK VALERE INDUSTRIAL, please have a look on separate description) >> article number: 881-880-HBS-7.0 (max. 7,0kVA) >> article number: 881-880-HBS-14.5 (max. 14,5kVA) >> article number: 881-880-HBS-30.0 (max. 50kVA)

  25. Modular Static Switches Series STS [1st Generation] UNB-5.0 - UNB-12.5 – UNB-23.0 – UNB-30.0 – UNB-40.0 Available DC input voltages of: 24 DC 5000VA 12500VA 23000VA 30000VA 40000VA 48/60V DC 110V DC 220V DC | --------------------------------------------------------- 19“ x 3U ------------------------------------------------------------ |

  26. Static Switches Series UNB UNB Technical information Input: DC input: Special version for 24VDC, 48/60VDC, 110VDC or 220VDC AC bypass input: 230VAC, 50/60 Hz, single phase also available 3x 230/400VAC, 50Hz, three phase with loadable neutral AC inverter input: 230VAC, 50/60Hz, single phase also available 3x 230/400VAC, 50Hz, three phase with loadable neutral Output:230V, 50/60Hz, single phase, in phase with bypass input also available 3x 230/400VAC, 50/60 Hz, three phase with loadable neutral, in phase with bypass input Free programmable operation mode (inverter to load / bypass to load as standard)

  27. Static Switches Series UNB UNB Signalling Relay signalling: Dry contact for common alarm. Contact rating: 8A@230VAC, 8A@24VDC Second source (substitute source) Priority source Operation Display of 4 lines Common alarm Synchron bus in phase with bypass mains input Load on Mains Load on Inverter

  28. Static Switches Series UNB UNB Special features >> Hot-plug-in able >>Display for all main operating parameters, settings and measuring values >> Optional three phase versions >> Designed for AC systems consisting of UNV- or PWS inverters >> Transfer time < 4ms >> Monitoring of both incoming sources according to voltage level, frequency and synchronisation >> Temperature controlled fan cooling (font-to-rear airflow) >>Free programmable operation mode (inverter priority or bypass priority) >> Overload capability 1000% for 10ms >> CAN bus interface

  29. Static Switches Series UNB UNB Needed / available accessories >> mounting kit >> article number: 880-MEC-MKT.01 (5.0 to 12.5kVA) >> article number: 880-MEC-MKT.03 (> 23.0kVA) >> Manual bypass switches (recommended by ELTEK VALERE INDUSTRIAL, please have a look on separate description) >> article number: 881-880-HBS-7.0 (max. 7,0kVA) >> article number: 881-880-HBS-14.5 (max. 14,5kVA) >> article number: 881-880-HBS-30.0 (max. 50kVA) Needed / available accessories >> socket (standard: part of delivery scope) >> article number: 880-MEC-MKT.21

  30. Other applicable products? • Inverter with built-in static switch • UNV-UE series • Input: 48/60VDC • Output: 230V/50Hz/1000VA out • Mechanical design: 19” x 3U

  31. Other applicable products? • Monoblock inverter • MBI series • Input: 110VDC or 220VDC • Output:115VAC or 230VAC • 30-50kAV • (up to 100kVA at 220VDC) • Mechanical design: • stand cabinet in RAL7035

  32. Other applicable products? • Monoblock UPS systems • MBS series • Input: 3x 230/400VAC • Output:1ph. 230VAC or 115VAC • 50 or 60 Hz • 60 up to 100kVA • Mechanical design: • stand cabinet in RAL7035

More Related