Bishop Steering Technology IIPrecision MeasurementDevice Hong Zhu Kyle Powell David K. Spaeth Patrick Richardson
Reason for the Design • Present measurement techniques are not accurate enough • Ensure consistent measurements between the various tiers involved in the industry • Improper measurement can result in a part being accepted that will fail when the whole steering system is tested • Properly measured parts facilitate cooperation between suppliers • Fewer returned parts will reduce costs
Main Requirements • Client needs two measurement systems to measure components of a rack and pinion steering system • Measurements must not have a difference greater than +/- 3microns from true value • Device must not be overly complicated
How Small is Three Microns? • The average skin cell is four microns in diameter • The average human hair is 70 microns in diameter
Problems with poorly measured shafts and sleeves • If the shaft and sleeve are not accurately machined, the flow of hydraulic fluid through them will not be even • The car may turn even though the steering wheel is in the neutral (center) position • The car may be more difficult to turn in one direction than the other • Increased costs due to repairs and bad parts
Process Control • The measuring process must be consistent • Because of the high accuracy required, the test facility must be in a pristine, laboratory-like environment • The environment must be controlled and free of dust and other fugitive material that could be detrimental to the measuring process
Thermal Control • Any variation in temperature cause the size of a shaft or sleeve to change by more than three microns • Transfer of human body heat to the shafts and sleeves must be minimized • The ambient room temperature must be kept constant
Sensors • It is necessary to record both linear and angular displacements • The challenge was to find a way to record both displacements at the same time
Linear Distance Sensor • For the shaft measurement we propose the use of a Keyence LK-011 laser
Linear Distance Sensor • For the sleeve we propose the Philtec Fiber Optic linear displacement sensor
Angular Displacement Sensor • The angular encoder can measure the angular rotation of a shaft to within 0.00005° accuracy
Sensor Mounting • Sensors are very sensitive, and must be stationary • So, the shafts and sleeves must be rotated so all the notches can be measured by the sensors • Why not design one device that holds both sensors stationary and measure both shafts and sleeves?
Positioning and Alignment • Measurement = Position +Alignment • By definition, linear and angular measurements require exact positioning and alignment • Precision measurement requires precision equipment
X-Y Tables • Micrometer driven tables allow for accurate positioning • Movable on one or two axes
Bellows Type Flexible Couplings • Rotation of shaft or sleeve must be the same as rotation of encoder • Unique design ensures that rotation is the same at top and bottom of coupling and that shafts are aligned
Bearing • Browning Spherical Roller Bearing • Low radial runoutof 1.5 microns
Use of a Stock Motor and Gear Reducer • Small motors capable of turning the shafts and sleeves at constant speed are common and available for purchase • We will use a Parker Automation stepper motor and a Daedel gear reducer
Data Acquisition and Analysis • Both the Keyence laser and Philtec fiber optic sensor are sold with electronics that acquire and process the data • Output is usually digital, but analog output devices with graphical displays are available
Patents and Trademarks • We have found no exact matches for the proposed designs • There are patented designs for similar components, but no design that incorporates them into a single system • The Laser Micro100 by BLUM is the closest in theory to what we are attempting
Design Modeling • This project called for research and design, but not the building of a prototype • Pro-Engineer is a powerful software program that allows us to model the design • The components in our design are only representations of the actual parts
Conclusion We met the engineering requirements for accuracy and surpassed our task of designing a machine that could measure either the shaft or the sleeve… OUR DESIGN MEASURES BOTH! The technology to produce this measurement machine is available now
Recommendations • We suggest that a prototype of this design be made and tested. • Possible alternatives to our method of adjusting the gauge plate be investigated.
Consultants Dr. Jie Chen - IUPUI Jason Wou – Bishop Steering Daniel Crafton – Bishop Steering Andy Hartsock – Parker Automation Dr. A.K. Naghdi – IUPUI Sales Support – Heidenhain Dr. Vermuri – IUPUI, Physics Department
References • The Mechanical Design Process By David G. Ullman MCG, 2002 • Introduction to Laser Technology By Hitz, C. Breck, Hitz, Breck, Ewing, J. J.,Hecht, Jeff John Wiley & Sons Inc, 2001 • An Introduction to Fiber OpticsBy R. Allen Shotwell, E. Stewart Prentice Hall, 1996
Electronic References • www.keyence.com • www.howstuffworks.com • www.philtec.com • www.newport.com/ • www.isotech.net • www.scantron-net.co.uk/applications.htm#fibres • www.eng.warwick.ac.uk/~espbc/index.htm • www.microphotonics.com/ • www.beemerprecision.com/info.html • www.hephaist.co.jp/e/index.html • www.eminebea.com/usa/ • www.hansen-motor.com/ • www.mstores.umich.edu/