[14] SEISMIC ANALYSIS OF THE NATIONAL COMPACT STELLERATOR Experiment (NCSX)

[14] SEISMIC ANALYSIS OF THE NATIONAL COMPACT STELLERATOR Experiment (NCSX) PSFC/JA-04-25 Peter H. Titus May 17 2004. Stress – SRSS of All Loads. Run #7 First Mode. Mode 7 Run #4. Mode 8 Run #4. Figure North-South Response Spectrum Curve, TFTR/TPX Test Cell, ref [5].

khoi
Download Presentation

[14] SEISMIC ANALYSIS OF THE NATIONAL COMPACT STELLERATOR Experiment (NCSX)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. [14] SEISMIC ANALYSIS OF THE NATIONAL COMPACT STELLERATOR Experiment (NCSX) PSFC/JA-04-25Peter H. Titus May 17 2004 Stress – SRSS of All Loads Run #7 First Mode Mode 7 Run #4 Mode 8 Run #4

  2. Figure North-South Response Spectrum Curve, TFTR/TPX Test Cell, ref [5] Figure East-West Response Spectrum Curve, TFTR/TPX Test Cell, ref [5] Enveloped ARS – Use with a Factor of 2.0 [5]

  3. Global Reaction Summations .5g + deadweight Static Analysis Response Spectra Modal Analysis Global Reaction Summations

  4. Hilti Drop-In Hilti HDI Concrete Flush Anchor Tests Allowable Design Loads are ¼ these Values, i.e. a F.S. of 4 is recommended A shear design capacity of 13000 lbs and a tensile capacity of 9000lbs is recommended. These envelope static and modal analyses. For shear, use 13000/6224*4 = 8 ½ “ Hiltis, For Tension use 9000/6751*4=5 ½ “Hilties 13 ½ “ Hiltis Total per Leg -or For shear use 13000/9696*4 = 4 5/8 Hiltis, for Tension use 4 5/8 Hiltis Or 8 5/8 Hilti’s Total per Leg

  5. I Beam Support Column Static Analysis Results ¾ Hilti Test Capacity – Use ¼ Value This I Beam is Almost Completely in Compression This I Beam is Mostly in Tension – The Net Load is 35833 N or 8000 lbs – Small for ¾ inch bolts and Hiltis

  6. From DOE Regs Static Acceleration used in the original NSTX qualification Fp = Z I Cp WP = 0.135 Wp This analysis used .5g – For Extra Weight and Uncertainty This is 1e6*.2248/4 = 56200 lbs per Hilti Consider adding shear plates with many Hiltis on outboard Diagonal Braces

  7. Modal Analysis Results Fx=5675.1 Lbs Fy=6759.7 Lbs Fz=7529.0 Lbs Fx=9023.02 Lbs Fy=8078.6 Lbs Fz=6790.7 Lbs SRSS of Fx and Fz Shear= 11293lbs Fx=10131 Lbs Fy=1500.3 Lbs Fz=7673 Lbs SRSS of Fx and Fz Shear= 12709lbs Fx=5644.5 Lbs Fy=6674.5 Lbs Fz=6827.2 Lbs

  8. Static Analysis Results Fx=23875N Fy=28661 N Fz=-16142N Fx=5367 Lbs Fy=6443Lbs Fz=3628 Lbs SRSS of Fx and Fz Shear= 3900 lbs Fx=14230N Fy=-16801N Fz=9626.4N Fx=3199 Lbs Fy=377Lbs Fz=2163 Lbs SRSS of Fx and Fz Shear= 6500 lbs

  9. Modal Analysis Results

  10. Bottom Bellows Static .5g Lateral Analysis Bottom Bellows Modal Analysis

  11. Mode 2

  12. Mode 3

  13. Mode 4

  14. Mode 4