1 / 12

PMCC Flash Point Tester

PMCC Flash Point Tester is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends <br>and gas oils. It is designed as per u00e2u20acu0153Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)u00e2u20acu009d ASTM D93.<br>

kibmer
Download Presentation

PMCC Flash Point Tester

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Personalized PDF Catalog Catalog Generated On : 12/12/2023 PMCC Flash Point Tester

  2. https://www.labtron.info/ info@labtron.info | Description : PMCC Flash Point Tester is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. It is designed as per “Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)” ASTM D93.

  3. Specifications : Ambient temperatur ≤ 35 °C e Relative ≤ 85 % humidity 5 °C ~ 110 °C, Each scale division is 0.5 Temperatur °C; 20 °C ~ 150 °C, e range Each scale division is 1.0 °C; 90 °C ~ 370 °C,

  4. Each scale division is 2 °C Aperture of ignition 0.8 mm device Standard oil cup-Inner 50.7 ~ 50.8 mm diameter Standard oil 55.7 ~ 56.0 mm cup- Depth

  5. Standard oil cup- Depth of Marked 33.9 ~ 34.3 mm line on the oil cup Standard oil cup-Oil About 70 ml sample cubage

  6. 90 ~ 120 rpm for Stirring procedure A; 250 ± 10 speed rpm for procedure B Stirring 8 × 40 mm blade Sample temperatur 1 ~ 12 °C per minute e rising rate Heating 0 ~ 600 W power

  7. Dimension 420 × 350 × 350 mm Total Power Consumpti 600 W on Power AC 220 V ± 10 %, 50 supply Hz Features :

  8. Ignition source : Coal gas Rod type Mercury Thermom eter

  9. Variable Temperat ure Range 45TYZ Stirring Motor Applications : It is suitable to determine closed cup flash point of petroleum

  10. products having a flash point higher than 40 °C

  11. www.labtron.info Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

  12. Email: info@labtron.info | Website: https://www.labtron.info/ | Phone: +44 2080 043 608

More Related