1 / 12

Absorber Design for Synchrotron Radiation Sources

Absorber Design for Synchrotron Radiation Sources. S.Hermle, D.Einfeld, E.Huttel (FZK); G.Heidenreich(PSI) PAC99 S.Sharma,E.Rotela,A.Barcikowsk (APS) MEDSI00 L.Zhang, J.C.Biasci, B.Plan (ESRF) MEDSI02. SR Radiation Power. ANKA Absorber Design.

killianj
Download Presentation

Absorber Design for Synchrotron Radiation Sources

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Absorber Design for Synchrotron Radiation Sources S.Hermle, D.Einfeld, E.Huttel (FZK); G.Heidenreich(PSI) PAC99 S.Sharma,E.Rotela,A.Barcikowsk (APS) MEDSI00 L.Zhang, J.C.Biasci, B.Plan (ESRF) MEDSI02

  2. SR Radiation Power

  3. ANKA Absorber Design Storage ring: Lumped Absorber Distributed Absorber Front Ends. Mask Shutter

  4. Basic Absorber 10000 W / K m2 40 W / mm Cu: Conductivity: 380 W / Km Young module 120 GPa Expansion 0.000017 1 / K

  5. Material - Limits

  6. At the limit, what to do? Decline the Absorber 0.95 m > 1.7 m eff. Increase source distance: 1.3 m > 1.7 m Increase water flow Increase boundary surface Special: grooves and slots

  7. Basic Plate and Plate with Grooves (APS) 40 W / mm Tmax: 150 Tbound: 95 Tmax: 195 Tbound: 100

  8. ANKA,SLS,..SOLEIL (Heidenreich PSI) Tmax: 132 Tbound: 80 Tmax: 132 Tbound: 90 Stress reduction by allowing expansion

  9. Distributed Absorber Cu to LN316 bonded LN316 Al Extruded P: 5 W/mm Tmax: 75 °C Tbound 40 °C P: 2 W/mm Tmax: 60 °C Tbound 40 °C P: 0.5 W/mm Tmax: 50 °C Tbound 30 °C

  10. Front End SR Shutter (20 kW) P/l: 260 W / mm P/a: 6.5 W / mm2 A: 40 x 75 mm2 Tmax: 480 °C Tbound: 200 °C FMB ASP Shutter Absorber for reflected radiation

  11. ESRF Concept Vertical Declination Horizontal Declination (ESRF)

  12. ESRF Concept P/l: 260 W / mm P/a: 6.5 W / mm2 A: 40 x 75 mm2 Tmax: 340 °C Tbound: 100 °C P/l: 50 W / mm P/a: 25 W / mm2 A: 2 x 400 mm2 Tmax: 190 °C Tbound: 50 °C