90 likes | 100 Views
To pass DELL EMC DES-6321 Specialist - Implementation Engineer, VxRail Appliance Exam certification exam, you will have to obtain essentially Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest. As your achievement in the DELL EMC certification DES-6321 exam is entirely dependent around the DES-6321 practice exam questionsyou choose. The most valid DES-6321 exam questions and answers provided by the Killtest would be the most credible supply for the preparation as these DES-6321 exam questions and answers are verified by the DELL EMC experts.
E N D
The safer , easier way to help you pass any IT exams. 1.What components of a VxRail node must be assigned IP addresses? A. ESXi host. Center. ESRS. and iDRAC B. ESXi host, vSAN. Center. and ESRS C. ESXi host, vSAN. vMouon. and iDRAC D. vSAN. Center. vRealize Log Insight. and vMotion Answer: C 2.A system administrator wants to check the version of the VxRail Manager Plug-In. Where can this be done? A. vSphere Client > VxRail Cluster > Configure> VxRail Support B. vSphere Client > Menu Administration > Client Plug-Ins C. vSphere Web Client > Menu Administration > Client Plug-Ins D. VxRail Manager URL > System Health > Client Plug-Ins Answer: B 3.What is the maximum number of nodes in a VxRail Cluster with 25 GbE? A. 32 B. 64 C. 96 D. 128 Answer: B 4.Beginning with VxRail version 4.7, which product license option has changed? A. VSAN B. vCenter C. VMware Log Insight D. vSphere Answer: A 5.What type of license does the Dell 4100 OS 10 Switch require to support SmartFabric Services beyond the initial trial period? A. Feature specific licensing for SmartFabric Services B. Full Fabric Mode licensing Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest C. SmartFabric licensing D. Perpetual licensing Answer: D 6.A VxRail Cluster setup with P570F nodes is used for product evaluation purposes at customer sites. Before moving the Cluster to another customer site. it needs to be reset. Where is the image located to complete this task? A. MB Server B. IDSDM C. SATADOM D. BOSS 2 / 8
The safer , easier way to help you pass any IT exams. Answer: B 7.How long does it take for the Primary node to be selected for a VxRail deployment after all nodes have been powered on? A. 15 to 20 seconds B. 5 to 10 minutes C. 5 to 10 seconds D. 15 to 20 minutes Answer: D 8.What are all of the menu option choices available in the RASR factory reset procedure when booting from the RASR ISO? A. RASR RESET CREATE RASRUSB FACTORY RESET UPDATE FIRMWARE EXIT B. RASR RESET CREATE RASRUSB FACTORY RESET REBOOT UPDATE FIRMWARE QUIT C. RASR RESET CREATE RASRUSB FACTORY RESET QUIT D. RASR RESET CREATE RASRUSB FACTORY RESET REBOOT UPDATE FIRMWARE EXIT Answer: C 9.You are validating a VxRail deployment of six V570F nodes each with four 10 Gb connections. The VxRail nodes have not been powered on. You need to ensure that the Dell EMC ToR switch is configured correctly. Which command should you use to do this? A. show port-channel summary B. show interface status C. show interface trunk D. show running-config Answer: D Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest 3 / 8
The safer , easier way to help you pass any IT exams. 10.How many nodes can be added simultaneously to an easting VxRail Cluster? A. 1 B. 2 C. 4 D. 6 Answer: D 11.You have determined that you need to execute a RASR factory upgrade of a VxRail v4.7.1xx node. You download the RASR ISO from the Dell Support site. What is the correct order of steps to finish the upgrade? Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest Answer: 12.What VxRail VSAN storage policy should NOT be changed or deleted after the initial setup? A. VM Encryption Policy B. VSAN Default Storage Policy C. VxRAIL-STORAGE-PROFILLE D. VxRAIL-SYSTEM-STORAGE-PROFILE 4 / 8
The safer , easier way to help you pass any IT exams. Answer: D 13.In which VxRail models is the iDRAC NIC Selection Setting set to Dedicated? A. P570, V570, and S570 only B. E560 and G560 only C. P570, V570, S570 and G560 D. E560, P570. V570, and S570 Answer: D 14.What is the correct sequence of steps used by the VxRail NVT workflow? Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest A. Specifying Dell EMC- deployed switches and Stretched Clusters B. Generating the NVT/FDC JSON configuration file C. Deploying customer provided, non-Dell EMC network switches D. Manually configuring VxRail Manager Answer: A 16.What is the default VLAN ID of the Private Management VLAN network on a VxRail 4.7.x node? A. 0 B. 1 C. 3939 D. 4095 Answer: 15.What is the primary use of the VxRail PEQ Addendum? 5 / 8
The safer , easier way to help you pass any IT exams. Answer: C 17.Where are the vSAN logs stored? A. Standard ESXi host logs B. Master vSAN node C. VSAN appliance VM D. vCenter logs Answer: A 18.By design, which network is required to have IPv6 Multicast enabled in order to set up a VxRail with version 4.7.100? A. Public management network B. VSAN network C. vMotion network D. Private management network Answer: D 19.Which requirement must be met when expanding a VxRail G560F 3 node Cluster with a 4th G Series node in the same chassis? A. Node must be a hybrid node B. Node requires only the same processor type C. Node requires only the same drive configuration D. Node must be identical to the other three nodes Answer: D 20.During a VxRail 2 node Cluster deployment, what is a valid connectivity option? A. 2×10 GbE B. 4×25 GbE C. 4 x1 GbE D. 2×25 GbE Answer: A 21.A VxRail Stretched Cluster will be configured with four All-Flash nodes at each site based on the Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest following requirements: - PFTT=1 - SFTT=1 - FTM=Erasure Coding Based on the required usable capacity, what should be the planned capacity of the design? A. Single Site Capacity=200% Total Cluster Capacity=400% B. Single Site Capacity= 133% Total Cluster Capacity=266% C. Single Site Capacity = 100% Total Cluster Capacity= 200% 6 / 8
The safer , easier way to help you pass any IT exams. D. Single Site Capacity=150% Total Cluster Capacity=300% Answer: D 22.You have just upgraded a VxRail Cluster from version 4.5.x to version 4.7.x. You need to ensure that new VxRail 4.7.x nodes will be discovered without having to make any changes to the nodes. What action should you take on the existing configuration? A. In vCenter, set the VLAN ID of the Management Network distributed portgroup to 3939 B. Add a new VLAN to the ToR switches with ID 3939 C. Add a new VLAN to the ToR Switches with ID 3939 In vCenter, set the VLAN ID of the Management Network distributed portgroup to 3939 D. Add a new VLAN to the ToR switches with ID 3939 In vCenter, set the VLAN ID of the VxRail Management distributed portgroup to 3939 Answer: D 23.What is the default network traffic configuration for a VxRail node with 2 x 10 GbE ports? A. Management, vMotion, and Virtual Machines on Uplink1 VSAN on Uplink B. Management and vMotion on Uplink1 VSAN and Virtual Machines on Uplink2 C. Management and virtual Machines on Uplink1 VSAN and vMotion on Uplink2 D. Management Virtual Machines, and VSAN on Uplink1 vMotion on Uplink2 Answer: A 24.Which settings would you expect to find in the VXRAIL-SYSTEM-STORAGE-PROFILE? A. FTT = 1 Object space reservation (%) =0 B. FTT = 2 Object space reservation (9o) =0 C. FTT = 2 Object space reservation (%) =100 D. FTT = 1 Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest Object space reservation (%) =100 Answer: D 25.In a VRail Stretched Cluster deployment. what is the required Round Trip Time (RTT) between sites? A. Primary to Witness site RTT: < 150 ms Secondary to Witness site RTT: < 150 ms Primary to Secondary site RTT: < 10 ms B. Primary to Witness site RTT: < 250 ms Secondary to Witness site RTT: < 250 ms Primary to Secondary site RTT: < 10 ms 7 / 8
The safer , easier way to help you pass any IT exams. C. Primary to Witness site RTT: < 200 ms Secondary to Witness site RTT: < 200 ms Primary to Secondary site RTT: < 5 ms D. Primary to Witness site RTT: < 10 ms Secondary to Witness site RTT: < 10 ms Primary to Secondary site RTT: < 6 ms Answer: C 26.What is the minimum number of VxRail nodes required for a SAN storage policy with FTT = 2 and FTM set to Erasure Coding? A. 4 B. 5 C. 6 D. 7 Answer: C Updated VxRail Appliance DES-6321 Test Questions V10.02 Killtest 8 / 8