1 / 17

CompuGROUP Holding AG The vita- X Health Record

CompuGROUP Holding AG The vita- X Health Record. Sofia, 2008/02/13. Manfred Glanzer, Senior Consultant E-Health, SYSTEMA Human Information Systems / Austria. (manfred.glanzer@systema.info).

kimball
Download Presentation

CompuGROUP Holding AG The vita- X Health Record

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CompuGROUP Holding AG The vita-XHealth Record Sofia, 2008/02/13 Manfred Glanzer, Senior Consultant E-Health, SYSTEMA Human Information Systems / Austria (manfred.glanzer@systema.info) CompuGROUP Holding AG - Maria Trost 21 - 56070 Koblenz - Tel.: 0261 8000-0 - Fax: 0261 8000-1166 - E-Mail: holding@compugroup.com - Internet: www.compugroup.com

  2. CompuGROUP - Facts • Founded in 1987, HQ in Koblenz / Germany • European wide customer base of approx. 290.000 GP‘s, dentists and other health care suppliers • Approx. 1.700 employees in Germany, France, Italy, Austria, Poland, Slovakia, Spain, Turkey and Czech Republic • Major line of business: communication solutions for international health care markets • GP software • Dental software • Hospital information systems • Medical Decision Support System to assist medical therapy and prescription • Web based electronic health record • Communication services, data analysis and Content-supply • Workflow-solutions and services for GP (networks), medical centers, hospitals, health insurances and pharmaceutical companies

  3. Medical data sharing Electronic Health Records

  4. directed non directional ? communication methods • receiver/ time of usage is unknown • information is shared without a specific request • requires a central storage for medicaldata or a central registry • part of the usual medical treatment process • transfer of specific med. documents at a certain point in time • document-exchange between one sender and receiver

  5. patient centric data sharing  CompuGROUP approach • Patient empowerment • Patient has his/her own physical data repository • full governance (patient is data-owner) • doctor-guided (family physician) • Patient is an active player in the sharing -process

  6. secure • server based EHR • integrated • patient centric simplification CompuGROUP approach • encrypted storage (unreadable for ‘data-hoster’) • increases availability (vs. decentralized approach) • RBAC (can be defined by the patient) • cost-effective central database vs. multiple registries/repositories (no add. hosting services,…) • Smart Card-based • smart client adaptor - handles client-side encryption/decryption (no special HW needed) • - communication with existing SW • directed communication with patient as active participant (empowerment) • data governance (patient is data-owner) • fewer components/resources (Hard- and Software, maintenance-personnel) • fewer dependencies • vs. decentralized  independent on availability of Health-Provider’s systems • security concept preserves confidentiality • usually addresses all legal requirements • increased acceptance (patients & doctors)

  7. CompuGROUP’s Solution Electronic Health Record

  8. logon server adaptor directory server PRIMARYSYSTEM(GP-System,HIS,…) data server Health professional vita-X - overview • handle authorization • provide session-keys • stores pointers to data-packets • encrypted & fragmented EHR-data

  9. confidence vita-X - security data protection has the highest priority! - keys are stored on the smart-card onlysmart-card & pin-code are needed to access the EHRno encryption-key is ever sent to or stored on the central server(s) • encryption/decryptionperformed by client-adaptor onlyadditional transport encryption is used • encrypted and fragmented Datastore cannot be associated with a physical personencrypted EHR-objects are spread amongst different data serversserver-side decryption is virtually impossible • RBAC, Logging and Auditingrestrict EHR-access (based on doctor’s medical field,…)documents access to EHR, provide access-history • Confidentiality is preserved • Risk of unauthorized access is minimized • Increased acceptance (patients & health professionals)

  10. vita-X - content • structured / unstructured • Each Medical Data Object (MDO) is structured (author, creation-date, type,…) and can have an unlimited number of unstructured attachments. • Supports the use of (international) classifications like ICD-10, OPS (Operations and Procedural Key), PZN (Central Pharmaceutical Number),… • machine readable data objects allow efficient integration of modern decision support systems(drug interaction check modules,…) and data-import into the HP’s primary system • stores any document typeas MDO-attachment • digital signaturesEach MDO is digitally signed by the author • content areashealth-professional area (crypto+)patient-area (Org)

  11. vita-X - accessibility • multiple authentication levels • dual/single Smart Card based • patient-access without HP-Smart Card(eg. vita-X Patient-Terminals in Hospitals) • extended Health Provider Access(allow a HP to access the EHR without the patient’s Smart Card for a specific period of time) • ‘Integration instead of isolation’ • vita-X client adaptor allows full integration into primary system • smart-client • secure client-interface to access the vita-X EHR. • browser based • using signed java-applet (browser-sandbox) to connect to card-reader and vita-X system

  12. vita-X – front-end vita-X pro • for health-professionals • data is stored in HP-content-area (Patient’s can not manipulate the data, but configure RBAC) • HP-verified content • Information at a glance (prima vista) • risk factors, permanent medication,…. vita-X home • for patients • data is stored in patient-content-area • patient has full control • for self-monitoring purposes

  13. quality improvement, process optimization, cost reduction increased self responsibility, better health vita-X – benefits for sponsors & health providers • enables cross institutional communication • Support of disease management programs (cross institutional information management) • reduces double examinations • integrates into existing applications & workflow • provides consolidated view on (all) important facts of patient’s medical history • quick overview on patient’s health-status • allows better drug interaction checks • optimization of treatment-process (anamnesis,…) for patients • transparency of medical treatment • benefit of quality improvement • access to EHR from anywhere, anytime

  14. Electronic Health Record Projects

  15. Pilot project „ePA Rheinland-Pfalz“ started on November 29th,2004 by Malu Dreyer (Secretary of Health) vita-X – projects • Goals: • networking of 50 general practitioners and 2 hospitals • electronic data exchange between general practitioners and hospitals without media disruption

  16. ePA Junior vita-X – projects • initiative of government, physicians association and CompuGROUP Holding AG • free personal electronic health record for all newborns of the year 2008 in Rheinland-Pfalz (Germany) • first prevention model for infantile health in Germany • first area-wide adoption of a professional-guided personal electronic health record • continuous documentation up to the 6. birthday • sponsors: • state of Rheinland-Pfalz / Germany (ministry for work, social affairs, health,family and women) • CompuGROUP Holding AG

  17. one step ahead Thank you for your attention. If you have any questions or need more information on CompuGROUP’s software-solutions, do not hesitate to contact us. Visit our Web-page at www.compugroup.com to request product-specific information

More Related