1 / 66

Fire Protection in Shipyard Employment

Fire Protection in Shipyard Employment. General provisions. Purpose and Scope 501 Fire safety plan 502 Precautions before hot work 503 Fire watches 504 Fire response 505 Hazards of fixed extinguishers on board vessel 506 Landside fire protection system 507 Training 508. Purpose.

kimberly
Download Presentation

Fire Protection in Shipyard Employment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fire Protection in Shipyard Employment

  2. General provisions • Purpose and Scope 501 • Fire safety plan 502 • Precautions before hot work 503 • Fire watches 504 • Fire response 505 • Hazards of fixed extinguishers on board vessel 506 • Landside fire protection system 507 • Training 508

  3. Purpose • Requires employers to protect all employees from fire hazards in shipyard employment, including employees engaged in fire response activities • Provides increased protection for shipyard employment workers from the hazards of fire on vessels and vessel sections and at land-side facilities • Reflects new technologies and national NFPA consensus standards

  4. Scope • Covers employers with employees engaged in • Shipyard employment aboard vessels and vessel sections • Land - side operations • Regardless of geographic locations

  5. Employee participation • Employer’s must provide for employees or employee representatives to participate in developing and reviewing programs and policies to comply with this subpart

  6. Multi-employer worksites • Host employer responsibilities • Inform employers about the content of the fire safety plan including hazards, controls, fire safety and health rules, and emergency procedures • Ensure safety and health responsibilities for fire protection are assigned as appropriate to other employers at the worksite

  7. Multi-employer worksites (cont’d) • Contract employer responsibilities • Ensure host employer knows about the fire-related hazards associated with the contract employer's work and what the contract employer is doing to address them • Advise the host employer of any previously unidentified fire- related hazards that the contract employer identifies at the worksite

  8. Fire safety plan29 CFR 1950-502 • Employer responsibilities • Plan elements • Reviewing the plan with employees • Additional employer requirements • Contract employers

  9. Plan elements • Plan must include: • Identification of significant fire hazards • Procedures for recognizing and reporting unsafe conditions • Alarm procedures • Procedures for notifying employees of a fire emergency • Procedures for notifying fire response organizations of a fire emergency • Procedures for evacuation • Procedures to account for all employees after an evacuation; and • Names, job titles, or departments or individuals who can be contacted for information about the plan

  10. Reviewing the plan with employees • The employer must review the plan with each employee at the following times: • By March 14, 2004, for current employees • Upon initial assignment for new employees; and • When the actions the employee must take under the plan change because of a change in duties or a change in the plan.

  11. Additional plan requirements • Must be accessible to employees, employee representatives and OSHA • Review and update at least annually • Document affected employees have been informed about the plan • Give a copy to outside fire response organizations that will respond to fires

  12. Contract employers • Contract employers in shipyard employment must have a fire safety plan for their employees, and the plan must comply with the host employer's fire safety plan • The contract employer can adopt the host employers fire safety plan to meet this requirement

  13. Precautions for hot work29 CFR 1915 – 503 • General requirements • Designated areas • Non-designated areas • Specific requirements • Maintaining fire hazard free conditions • Fuel gas and oxygen supply line and torches

  14. General requirements - designated areas • The employer may designate areas that are free of fire hazardsfor hot work in sites such as: • Vessels • Vessel sections • Fabricating shops • Subassembly areas

  15. Non-designated areas • Visually inspect area where hot work will be performed, including adjacent areas unless Marine Chemist’s certificate or Shipyard Competent person’s logs is used for authorization • Perform hot work only in areas that are free of fire hazards, or controlled by physical isolation, fire watches, etc. • Maintain fire hazard-free conditions

  16. Precautions for hot work – specific requirements • Fuel gas and oxygen supply lines and torches • No unattended lines in confined spaces • No unattended charged lines in enclosed spaces for more than 15 minutes • Fuel gas and oxygen hose lines disconnected at end of each shift

  17. Precautions for hot work – specific requirements (cont’d) • Roll lines back to supply manifold or open air and then disconnect torch, or • Disconnect extended fuel gas and oxygen hose lines at the the supply manifold • Only if the lines are given a positive means of identification • Use a drop test or other positive means to ensure the integrity of fuel gas and oxygen burning system before resuming hot work

  18. Fire watches29 CFR 1915 - 504 • Written policy • Posting fire watches • Assigning employees to fire watch duty

  19. Written policy • Detailed fire watch training • Identifies duties employees will perform and equipment they will be given • Includes personal protective equipment (PPE) that must be made available and worn

  20. Posting fire watches • Must post a fire watch during hot work if any of the following are present: • Slag, weld splatter, or sparks might pass through an opening and cause a fire • Fire-resistant guards or curtains are not used to prevent ignition of combustible materials on or near decks, bulkheads, etc • Combustible material is closer than 35 ft. and cannot be removed, shielded or protected

  21. Posting fire watches (cont’d) • Hot work is carried out on or near insulation, combustible coatings that cannot be shielded, cut back, removed, or inerted • Combustible materials adjacent to the opposite sides of bulkheads, decks, etc. may be ignited by conduction or radiation • The hot work is close enough to cause ignition through heat radiation or conduction on: • Insulated pipes, bulkheads, decks, partitions, or overheads; or • Combustible materials and/or coatings

  22. Posting fire watches (cont’d) • The work is close enough to unprotected combustible pipe or cable runs to cause ignition • A Marine Chemist, a Coast Guard-authorized person, or a shipyard Competent Person requires that a fire watch be posted

  23. Assigning employees to fire watch duty • Employees must not be assigned additional duties while the hot work is in progress • Employees must be physically capable of performing fire watch duties • Employees assigned to fire watch duty must: • Have a clear view and immediate access to all areas included in the fire watch • Be able to communicate with workers exposed to hot work • Be authorized to stop work and restore safe conditions within hot work area

  24. Assigning employees to fire watch duty (cont’d) • Remain in the hot work area for 30 minutes after completion of the hot work - Unless the employer or its representative surveys the exposed area and makes a determination that there is no further fire hazard • Be trained to detect fires in areas exposed to the hot work • Extinguish incipient stage fires in the hot work area • Alert employees of any fire beyond the incipient stage; and • If unable to extinguish fire, activate the alarm

  25. Fire response29 CFR 1915 – 505 • Employer responsibilities • Written policy information • Internal response • External response • Medical requirements for shipyard response employees • Organization of internal fire response functions • Personal protective clothing and equipment for fire response employees • Equipment maintenance (PPE)

  26. Employer responsibilities • Decide what type of response will be provided and who will provide it • Internal fire response • Outside fire response • Create, maintain, and update a written policy that: • Describes the internal and outside fire response organizations that the employer will use; and • Defines evacuation procedures, if the employer chooses to require a total or partial evacuation of the worksite at the time of a fire

  27. Written policy – internal response • The basic structure of the fire response organization • Number of trained fire response employees • The fire response functions that will be carried out • Minimum number of fire response employees necessary • Type, amount, and frequency of training that must be given to fire response employees • Procedures for using protective clothing and equipment

  28. Written policy – outside response • Types of fire suppression incidents to which the fire response organization is expected to respond at the employer's facility • Liaisons between the employer and the outside fire response organizations

  29. Written policy – outside response (cont’d) • A plan for fire response functions that: • Addresses procedures for obtaining assistance from the outside fire response organization • Familiarizes the outside fire response organization with the layout of the employer's facility or worksite • Sets forth how hose and coupling connections will be made compatible and location of adapter couplings • States employer will not allow use of incompatible hose connections

  30. Written policy – combination of internal and outside response • The basic organizational structure of the combined fire response • Number of combined trained fire responders • Fire response functions that may need to be carried out • Minimum number of fire response employees necessary • Number and types of apparatuses, and • Description of the fire suppression operations established by written standard operating procedures for each particular type of response at the worksite • Type, amount, and frequency of joint training with outside fire response organizations

  31. Employee evacuation • Emergency escape procedures • Procedures to be followed by employees who remain at worksite to perform critical operations during the evacuation • Procedures to account for all employees after emergency evacuation is completed • Means of reporting fires and other emergencies • Names or job titles of employees or departments to be contacted for further information or explanation of duties

  32. Written emergency response • The employer must include the following information in the employer's written policy: • A description of the emergency rescue procedures; and • Names or job titles of the employees who are assigned to perform them

  33. Medical requirements for shipyard fire response employees • The employer must ensure that: • Fire response employees receive medical exams to assure they are physically and medically fit for duties expected to perform • Fire response employees, required to wear respirators meet the medical requirements • Each fire response employee has an annual medical examination; and • Medical records are kept on fire response employees

  34. Organization of internal fire response functions • Organize fire response functions to ensure adequate resources for emergency operations • Establish lines of authority and assign responsibilities to ensure components of the internal fire response are accomplished • Set up incident management system to coordinate and direct fire response functions, including: • Specific fire emergency responsibilities • Accountability for all fire response employees participating in an emergency operation; and • Resources offered by outside organizations • Provide information as required to the outside fire response organization to be used

  35. PPE for fire response employees • General requirements • Thermal stability and flame resistance • Respiratory protection • Interior structural firefighting operations • Proximity firefighting operations • Personal alert safety system (PASS) devices • Life safety ropes, body harnesses and hardware

  36. General requirements • Employer must: • At no cost, supply all fire response employees appropriate personal protective clothing and equipment they need to perform expected duties • Ensure employees wear the appropriate PPE and use the equipment, when necessary, to protect them from hazardous exposures

  37. Thermal stability and flame resistance • Ensure each fire response employee exposed to flame hazards do not wear clothing that could increase the extent of injury • Prohibit wearing clothing made from acetate, nylon, or polyester, either alone or in blends, unless it can be shown that: • The fabric will withstand the flammability hazard that may be encountered; or • The clothing will be worn in such a way to eliminate the flammability hazard that may be encountered

  38. Personal Alert Safety System (PASS) devices • Provide each fire response employee involved in firefighting operations with a PASS device; and • Ensure that each PASS device meets the recommendations in NFPA 1982-1998 Standard on Personal Alert Safety Systems (PASS)

  39. Life safety ropes, body harnesses and hardware • The employer must ensure that: • All life safety ropes, body harnesses, and hardware used by fire response employees for emergency operations meet the applicable recommendations in NFPA 1983-2001 • Fire response employees use only Class I body harnesses to attach to ladders and aerial devices; and • Fire response employees use only Class II and Class III body harnesses for fall arrest and rappelling operations

  40. Equipment maintenance • Personal protective equipment • Employer must inspect and maintain PPE used to protect fire response employees to ensure that it provides the intended protection • Fire response equipment. • Keep fire response equipment in a state of readiness • Standardize all fire hose coupling and connection threads throughout the facility • Ensure all fire hoses and coupling connection threads are the same throughout the facility as those used by the outside fire response organization, or • Supply suitable adapter couplings if such an organization is expected to use the fire response equipment within a facility or vessel or vessel section

  41. Hazards of fixed extinguishing systems on board vessels and vessel sections – 29 CFR 1915 - 506 • Employer responsibilities • Requirements for automatic and manual systems • Sea and dock trials • Doors and hatches • Testing the system • Conducting system maintenance • Using fixed manual extinguishing systems for protection

  42. Employer’s responsibilities • The employer must comply with the provisions of this section whenever employees are exposed to fixed extinguishing systems that could create a dangerous atmosphere when activated in vessels and vessel sections, regardless of geographic location

  43. Requirements for automatic and manual systems • Before working in a a space with a fixed system, either: • Physically isolate the systems or use other positive means to prevent the systems' discharge; or • Ensure employees are trained to recognize: • Systems' discharge and evacuation alarms and the appropriate escape routes; and • Hazards associated with the extinguishing systems and agents including the dangers of disturbing system components and equipment

  44. Sea and dock trials and door hatches • During trials, the employer must ensure that all systems remain operational • Take protective measures to ensure all doors, hatches, scuttles, and other exit openings remain working and accessible for escape in the event the systems are activated; and

  45. Sea and dock trials and door hatches(cont’d) • Ensure that all inward opening doors, hatches, scuttles, and other potential barriers to safe exit are removed or blocked open, if systems' activation could result in a positive pressure in the protected spaces sufficient to impede escape

  46. Testing the system • When testing a fixed extinguishing system involves a total discharge of extinguishing medium into a space, employer must: • Evacuate all employees from space and assure no employees remain in the space during the discharge • Retest the atmosphere to ensure that the oxygen levels are safe for employees to enter • When testing a fixed extinguishing system does not involve a total discharge of the systems extinguishing medium, employer must: • Ensure system's extinguishing medium is isolated • All employees not directly involved in the testing are evacuated from the protected space

  47. Conducting system maintenance • Before conducting maintenance on a fixed extinguishing system, the employer must ensure that the system is physically isolated

  48. Using fixed manual extinguishing systems for fire protection • If fixed manual extinguishing systems are used to provide fire protection for spaces in which the employees are working, the employer must ensure that: • Only authorized employees are allowed to activate the system • Authorized employees are trained to operate and activate the systems; and • All employees are evacuated from the protected spaces, and accounted for, before the fixed manual extinguishing system is activated

  49. Land-side fire protection systems 29 CFR 1915 - 507 • Employer responsibilities • Portable fire extinguishers and hose systems • Fixed extinguishing systems

  50. Employer responsibilities • Ensure all fixed and portable fire protection systems needed to meet OSHA standard for employee safety or employee protection from fire hazards in land- side facilities meet the requirements, including, but not limited to: • Buildings • Structures • Equipment

More Related