1 / 41

New gaseous detectors: the application of pixel sensors as direct anode

New gaseous detectors: the application of pixel sensors as direct anode. Harry van der Graaf NIKHEF, Amsterdam IEEE-NSS Conference, Rome N17-4, Oct 19, 2004. NIKHEF Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers

Download Presentation

New gaseous detectors: the application of pixel sensors as direct anode

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New gaseous detectors: the application of pixel sensors as direct anode Harry van der Graaf NIKHEF, Amsterdam IEEE-NSS Conference, Rome N17-4, Oct 19, 2004 NIKHEF Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Maximilien Chefdeville Saclay CEA DAPNIA Paul Colas Yannis Giomataris Arnaud Giganon Univ. Twente/Mesa+ Jurriaan Schmitz CERN/Medipix Constm Eric Heijne Xavie Llopart Michael Campbell Thanks to: Wim Gotink Joop Rovenkamp

  2. Original motivation: Si pixel readout for the Time Projection Chamber (TPC) at TESLA (now ILC)

  3. Time Projection Chamber (TPC): 2D/3D Drift Chamber The Ultimate Wire (drift) Chamber track of charged particle E-field (and B-field) Wire plane Wire Plane + Readout Pads Pad plane

  4. Wireless wire chambers: better granularity 1995 Giomataris & Charpak: MicroMegas

  5. Wireless wire chambers: better granularity 1996: F. Sauli: Gas Electron Multiplier (GEM)

  6. Problem With wires: measure charge distribution over cathode pads: c.o.g. is a good measure for track position; With GEMs or Micromegas: narrow charge distribution (only electron movement) avalanche GEM wire Micromegas Cathode pads Solutions: - cover pads with resisitive layer - ‘Chevron’ pads - many small pads: pixels

  7. The MediPix2 pixel CMOS chip Cathode foil Drift Space Gem foils Support plate Medipix 2 We apply the ‘naked’ MediPix2 chip without X-ray convertor!

  8. MediPix2 & Micromegas 55Fe Cathode (drift) plane Drift space: 15 mm Micromegas Baseplate MediPix2 pixel sensor Brass spacer block Printed circuit board Aluminum base plate Very strong E-field above (CMOS) MediPix!

  9. 55Fe, 1s No source, 1s 55Fe, 10s 14 mm Signals from a 55Fe source (220 e- per photon); 300 m x 500 m clouds as expected The Medipix CMOS chip faces an electric field of 350 V/50 μm = 7 kV/mm !! We always knew, but never saw: the conversion of 55Fe quanta in Ar gas

  10. Single electron efficiency • no attachment • homogeneous field in • avalanche gap • low gas gain •  • No Curran or Polya • distributions but simply: Prob(n) = 1/G . e-n/G Eff = e-Thr/G Thr: threshold setting (#e-) G: Gas amplification

  11. New trial: NIKHEF, March 30 – April 2, 2004 Essential: try to see single electrons from cosmic muons (MIPs) Pixel preamp threshold: 3000 e- Required gain: 5000 – 10.000 New Medipix New Micromegas Gas: He/Isobutane 80/20 Ar/Isobutane 80/20 He/CF4 80/20 …… It Works!

  12. He/Isobutane 80/20 Modified MediPix Sensitive area: 14 x 14 x 15 mm3 Drift direction: Vertical max = 15 mm

  13. He/Isobutane 80/20 Modified MediPix

  14. He/Isobutane 80/20 Modified MediPix

  15. He/Isobutane 80/20 Non Modified MediPix Americium Source

  16. He/Isobutane 80/20 Modified MediPix

  17. He/Isobutane 80/20 Modified MediPix δ-ray!

  18. After 24 h cosmic ray data and 3 broken chips: • We can reach very high gas gains with He-based gases (> 100k!) • The MedPix2 chip can withstand strong E-fields (10 kV/mm!) • Discharges ruin the chip immediately (broke 4 in 4 days!) • Measured efficiency: > 0.9; consistent with high gain • Seen MIPs, clusters, δ-rays, electrons, α ‘s…… • - In winter 2004: beam tests (dE/dX: e-, pions, muons,……), • X-rays (ESRF, Grenoble); • - Development of TimePix 1: TDC per pixel instead of counter

  19. Integrate GEM/Micromegas and pixel sensor: InGrid ‘GEM’ ‘Micromegas’ Monolitic detector by ‘wafer post processing’

  20. ‘Try first Micromegas: simpel’ InGrid By ‘wafer post processing’ at MESA+, Univ. of Twente

  21. HV breakdowns 1) High-resistive layer 3) ‘massive’ pads 2) High-resistive layer 4) Protection Network

  22. Other application: GOSSIP: tracker for intense radiation environment: Vertex detector forSLHC

  23. MIP Cathode foil CMOS chip ‘slimmed’ to 30 μm Drift gap: 1 mm Max drift time: 15 ns MIP Micromegas CMOS pixel array An thin TPC as vertex detector GOSSIP: Gas On Slimmed SIlicon Pixels

  24. Essentials of GOSSIP: • Generate charge signal in gas instead of Si (e-/ions versus e-/holes) • Amplify # electrons in gas (electron avalanche versus FET preamps) • Then: • No radiation damage in depletion layer or pixel preamp FETs • No power dissipation of preamps • No detector bias current • Ultralight detection layer (Si foil+ 1 mm Ar gas) • 1 mm gas layer + 20 μm gain gap + CMOS (almost digital!) chip • After all: it is a TPC with 1 mm drift length (parallax error!) Max. drift length: 1 mm Max. drift time: 16 ns Resolution: 0.1 mm  1.6 ns

  25. Ageing Power dissipation Material budget Rate effects Radiation hardness Efficiency Position resolution

  26. Ageing Remember the MSGCs…… • Little ageing: • the ratio (anode surface)/(gas volume) is very high w.r.t. wire chambers • little gas gain: 5 k for GOSSIP, 20 – 200 k for wire chambers • homogeneous drift field + homogeneous multiplication field • versus 1/R field of wire. Absence of high E-field close to a wire: • no high electron energy; little production of chemical radicals • Confirmed by measurements(Alfonsi, Colas) • But: critical issue: ageing studies can not be much accelerated!

  27. Power dissipation • For GOSSIP CMOS Pixel chip: • Per pixel: • - input stage (1.8 μA/pixel) • (timing) logic • Futher: data transfer logic • guess: 0.1 W/cm2 •  Gas Cooling feasible!

  28. Detector Material budget ‘Slimmed’ Si CMOS chip: 30 μm Si Pixel resistive layer 1 μm SU8 eq. Anode pads 1 μm Al Grid 1 μm Al Grid resistive layer 5 μm SU8 eq. Cathode 1 μm Al

  29. Rate effects 0 Q 20 ns SLHC @ 2 cm from beam pipe: 10 tracks cm-2 25 ns-1 400 MHz cm-2! • ~10 e- per track (average) • gas gain 5 k • most ions are discharged at grid • after traveling time of 20 ns • a few percent enter the drift space: time • Some ions crossing drift space: takes 20 – 200 μs! • ion space charge has NO effect on gas gain • ion charge may influence drift field, but this does little harm • ion charge may influence drift direction: change in lorentz angle ~0.1 rad • B-field should help

  30. Efficiency • Determined by gas layer thickness and gas mixture: • Number of clusters per mm: 3 (Ar) – 10 (Isobutane) • Number of electrons per cluster: 3 (Ar) - 15 (Isobutane) • Probability to have min. 1 cluster in 1 mm Ar: 0.95 • With nice gas: eff ~ 0.99 in 1 mm thick layer should be possible • But……. • Parallax error due to 1 mm thick layer, with 3rd coordinate 0.1 mm: • TPC/ max drift time 16 ns; σ = 0.1 mm; σ = 1.6 ns: feasible! • Lorentz angle • We want fast drifting ions (rate effect) • little UV photon induced avalanches: good quenching gas

  31. Position resolution 0 Q 20 ns • Transversal coordinates limited by: • Diffusion: single electron diffusion 0 – 40/70 µm • weighed fit: ava 20/30 µm • 10 e- per track: σ = 8/10 µm • pixel dimensions: 20 x 20 – 50 x 50 μm2 • Note: we MUST have sq. pixels: no strips (pad capacity/noise) • Good resolution in non-bending plane! • Pixel number has NO cost consequence (m2 Si counts) • Pixel number has some effect on CMOS power dissipation • δ-rays: can be recognised & eliminated • 3rd (drift) coordinate • limited by: • Pulse height fluctuation • gas gain (5 k), pad capacity, # e- per cluster • With Time Over Threshold: σ = 1 ns ~~ 0.1 mm

  32. Radiation hardness • Gas is refreshed: no damage • CMOS 130 nm technology: TID • NIEL • SEU: design/test • need only modest pixel input stage

  33. Gas instead of Si • Pro: • no radiation damage in sensor • modest pixel input circuitry • no bias current, no dark current (in absence of HV breakdowns..!) • requires (almost) only digital CMOS readout chip • low detector material budget • low power dissipation • (12”) CMOS wafer  Wafer Post Processing • no bump bonding • ‘simple’ assembly • operates at room temperature • less sensitive for X-ray background • 3D track info per layer • Con: • Gas chamber ageing: not known at this stage • Needs gas flow (but can be used for cooling….)

  34. Plans • InGrid 1 available for tests in November: • rate effects • ageing (start of test: test takes years) •  Proof-of-principle of signal generator: Xmas 2004! • InGrid 2: HV breakdowns, beamtests with MediPix (TimePix1 in 2005) • Gossipo: Multi Project Wafer test chip Dummy wafer

  35. New gaseous detectors: the application of pixel sensors as direct anode Harry van der Graaf NIKHEF, Amsterdam IEEE-NSS Conference, Rome N17-4, Oct 19, 2004 NIKHEF Auke-Pieter Colijn Alessandro Fornaini Harry van der Graaf Peter Kluit Jan Timmermans Jan Visschers Maximilien Chefdeville Saclay CEA DAPNIA Paul Colas Yannis Giomataris Arnaud Giganon Univ. Twente/Mesa+ Jurriaan Schmitz CERN/Medipix Constm Eric Heijne Xavie Llopart Michael Campbell Thanks to: Wim Gotink Joop Rovenkamp

More Related