Welcome. In Consideration. Of Our Canadian Friends. Celebrating a National Holiday (Queen) Victoria Day with Birthday Wishes. Welcome. Something New The Armor X2. Armor X2. AWN1500PM. AWN1300PM. AWN1000PM. Armor X2. AWN1500PM. AWN1300PM. AWN1000PM. 59”. 59”. 59”. 56 ½”. 52 ¼”.
E N D
In Consideration Of Our Canadian Friends Celebrating a National Holiday (Queen) Victoria Day with Birthday Wishes
Armor X2 AWN1500PM AWN1300PM AWN1000PM
Armor X2 AWN1500PM AWN1300PM AWN1000PM 59” 59” 59” 56 ½” 52 ¼” 48” 31” 31” 31”
Standard Features • 96% thermal Efficiency • 10:1 Turndown • ASME Heat Exchanger • 160 PSI (HLW) • (2) circulating pumps • (2) flow switches • WH Pump Control • Alarm contacts • Failure contacts • Run time contacts • Tank sensor • SMART System • Smart Touch Control • Cascade up to 8 units • 0-10 VDC input • Low flow safety control • Freeze protection • Time clock • Night setback • Service Reminder • Data Logging • Anti Cycling
Armor X2 • Design certified to ANSI Z21.10.3, water heater standard • CSA International approved for US and Canada • Heat Exchangers are ASEM Section IV, HLW Stamped (Note HLW stamped water heaters are exempt from CSD1) • SCAQMD approved for Low Nox • Meets Low Lead requirements for California & Vermont
Two Heat Exchangers in one Water Heater 2.0" Inlet Twin Stainless Steel “heat engines” 3.00" outlet 2.0" Inlet
Pumps AWN1300PM, AWN1500PM AWN1000PM Grundfos (PUM20007) ¾ h.p. Armstrong E2 (PUM20016) 2/5 h.p. 65 GPM 50 GPM
Piping AWN1000 100 GPM AWN1300 125 GPM AWN1500 130 GPM 3” manifolds minimum
Venting Construction filter For use when drawing combustion air from room only 6 inch vent connection all models
Venting Options Up to 100 equivalent feet
PVC, CPVC, Polypropylene, AL294C First 10 feet must Be CPVC (when using PVC)
Construction Copper Inlet Piping Flow Switches Stainless Steel Outlet manifold Condensate trap Iron frame
Two Heating Modules • Maximizes Input while minimizing footprint • Independent operation & Lead-Lag between exchangers • Provided with two circulating pumps • Provides 50% redundancy within the unit • Modules lead/lag equalizing run time • Minimizing venting costs • Minimizing piping costs • Single Point 120 vac Electrical Connection • AWN1000 16.9 amps (heater and pumps) • AWN1300, 1500 24.7 amps (heater and pumps)
Piping Configurations 2 AWN500 and 1 RJA200 1 AWN1000 and 1 RJA200
10 to 1 Turndown Heavy Load Light Load
AWN1000PM Temperature Rise
AWN1300PM Temperature Rise
AWN1500PM Temperature Rise
10:1 Turndown Cyclone