An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Track Fitting and Comparator Results Emu meeting @ UC Davis Feb. 26, 2005 Yangheng Zheng University of California, Los Angeles • Motivation & Introduction • Results

  2. Motivations • Check output from comparator chips (for both ME2/2 and ME1/1) • Get familiar with Stan’s track-fitting utility package (TrackFnd) • Test the unpacking software (ORCA/EmuDAQ) for test-beam 2004 data • Look at ME1/1 data from TB2004 Emu meeting @ UC Davis

  3. Stan’s Track Fitting Framework • Pedestal Subtraction • Precision Sampling Time  buckeye shaping • Cross Talk is a function of ts (capacitative+slightly resistive coupling between adjacent strips)  lookup table • Cathode Noise Correlation  unfired events • Fitting Gatti distribution  hit position / each layer • Track Finding  Kalman Filter • Track Fitting  A straight line least squares fit • Details can be found:http://www.physics.ohio-state.edu/~durkin/testbeam03/TrackFnd.htm Emu meeting @ UC Davis

  4. Data for Gatti Fitting INPUT DATA: strips time bins Largest pedestal subtracted ADC value OUTPUT: track hit position for each layer through the least squares fitting Emu meeting @ UC Davis

  5. Something New • New interface between TrackFnd and ORCA/EmuDAQ • Add options of gMinuit for fitting distributions of buckeye and Gatti • Change pedestal subtraction method • New constants for ME11 • cross talk • cathode noise correlation • Gatti parameters • strip width and no staggering Emu meeting @ UC Davis

  6. Buckeye Shaping 4tc Emu meeting @ UC Davis

  7. Peaking Time tc ME22 (tc33.25ns) ME11: smaller gas gap and wire spacing  shorter drifting time ME11(tc28ns) Emu meeting @ UC Davis

  8. Peak Charge Time Bins ME22 (TB2003) ME22 (TB2004) ME11 (TB2004) Emu meeting @ UC Davis

  9. Pedestal Subtraction • Standard method: subtracting first two time samples • Method 2: pedestals  empty event (lookup table for every strip) • Method 3: pedestals  fitting all available time samples for every event (buckeye shape + constant pedestal) Emu meeting @ UC Davis

  10. Pedestal Subtraction (cont.) ME22 (TB2004) Method 1 – Method 2 Method 3 – Method 2 Mean 1.041 RMS 3.17 Mean 4.322 RMS 5.901 Emu meeting @ UC Davis

  11. Pedestal Subtraction (cont.) ME22 (TB2004) ---- Method 1 ---- Method 2 ---- Method 3 Emu meeting @ UC Davis

  12. Cross Talk • a function of ts • determined by tracks passed within 0.05 strip width of the center of the strip ME22(TB2003) ME22(TB2004) ME11(TB2004) cross talk fraction small statistics ts(ns) Emu meeting @ UC Davis

  13. Cathode Noise Correlation • Determined from unfired strips • For time bins i and j, • For time bins 3, 4, 5, 6 (ADC counts) • For ME22, TB2003 and TB2004 show similar results • ME11 shows different noise correlation • No correlations between adjacent strips’ time bins (<1 count) ME22 (TB2003) ME22 (TB2004) ME11 (TB2004) Emu meeting @ UC Davis

  14. Gatti Parameters • half gas gap (h parameter) • configuration: ME22 4.75mm, ME11 3.00mm • fitting: ME22 4.91mm, ME11 2.99mm • strip width • ME22 8.5-16.0mm, ME11 3.15-7.6mm • number of wire group per layer • ME22 64, ME11 48 • strip staggering • ME22 0.5 strip, ME11 no staggering Emu meeting @ UC Davis

  15. 2 of Gatti Fitting = 0.08 for ME22 NDOF: 9 - 3 - 1 = 5 ME22 (TB2004) ME11 (TB2004) Mean 4.99 RMS 3.16 Mean 4.999 RMS 3.16 Entries Entries Investigating the large tail effect 2 2 Emu meeting @ UC Davis

  16. Event Displays ME22 (TB2004) ME11 (TB2004) Emu meeting @ UC Davis

  17. Residue (3rd Layer) 3rd layer removed from track fitting ME11 (TB2004) ME22 (TB2004) sigma=0.0177 sigma=0.0178 Emu meeting @ UC Davis

  18. Comparator Ouput Resolution fitted track position - comparator output Emu meeting @ UC Davis

  19. Left Half Hits vs Right Half Hits wrong output due to the ambiguous charge difference (see next slide) Emu meeting @ UC Davis

  20. Output Probability wrong assignment due to the ambiguous charge difference Emu meeting @ UC Davis

  21. Output Efficiency comparator output residue within ¾ strip correct strip# output correct comparator output Emu meeting @ UC Davis

  22. Summary • Unpacking software seems robust • Small changes applied to TrackFnd class • For ME22, results of track fitting of TB2003 can be fully reproduced. • For ME11, the large tail effect of 2 and systematic errors are under investigation • Comparator chip produced reasonable results for both ME11 and ME22 Emu meeting @ UC Davis