1 / 16

Fast Ethernet

Fast Ethernet. As a result of the need for a higher data rate, Fast Ethernet operating at 100 Mbps was designed. Uses CSMA/CD method access method. Its MAC sublayer responsibilities is to govern the operation of the access method

kiona-burke
Download Presentation

Fast Ethernet

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fast Ethernet • As a result of the need for a higher data rate, Fast Ethernet operating at 100 Mbps was designed. • Uses CSMA/CD method access method. • Its MAC sublayer responsibilities is to govern the operation of the access method • Frame format, minimum and maximum frame lengths and addressing are the same for Ethernet and Fast Ethernet. Data Link Layer

  2. Fast Ethernet (Continued…) • Its additional MAC sublayer responsibilities: • Autonegotiation – allows two devices to negotiate the mode or data rate of operation, which will: • Allow incompatible devices to connect to one another. • Allow one device to have multiple capabilities. • Allow a station to check a hub’s capabilities. Data Link Layer

  3. Physical Layer • The physical layer is made up of four sublayers: • RS • Medium independent • Responsible for passing of data in 4-bit format to the MII and the left over functions. • MII • An improved interface that can be used with both a 10- and 100 Mbps data rate. • Backward-compatible and features a parallel data path between RS & PHY. Data Link Layer

  4. Figure 14.20Fast Ethernet physical layer

  5. Physical Layer (Continued…) • PHY • Medium dependent • Responsible for encoding and decoding. • Can be internal or external. • MDI • A piece of hardware that is implementation specific. • Medium dependent. Data Link Layer

  6. Figure 14.21MII

  7. Physical Layer Implementation • Fast Ethernet can be categorised as either a two-wire or a four-wire implementation. Data Link Layer

  8. 100Base-TX • Uses two pairs of twisted-pair cable (either 5 UTP or STP) arranged in a physical star topology. • Allows the use of internal or external receiver. • Transceiver • Responsible for transmitting, receiving, encoding, decoding and collision detection. • Encoding • Performs 4B/5B block encoding to maintain synchronisation followed by MLT-3 encoding. Data Link Layer

  9. Figure 14.23100Base-TX implementation

  10. Figure 14.24Encoding and decoding in 100Base-TX

  11. 100Base-FX • Uses two pairs of fiber-optic cables arranged in a physical star topology. • Allows the use of internal or external receiver. • Transceiver • Responsible for transmitting, receiving, encoding, decoding and collision detection. • Encoding • Performs 4B/5B block encoding to maintain synchronisation followed by NRZ-I encoding. Data Link Layer

  12. Figure 14.25100Base-FX implementation

  13. Figure 14.26Encoding and decoding in 100Base-FX

  14. 100Base-T4 • Uses four pairs of category 3 or higher UTP cables. • Transceiver • Responsible for transmitting, receiving, encoding, decoding and collision detection. • Encoding • More complex encoding technique. • Performs 8B/6Tencoding to maintain synchronisation and reduce bandwitdh. Data Link Layer

  15. Figure 14.27100Base-T4 implementation

  16. Figure 14.28Using four wires in 100Base-T4

More Related