1 / 29

Advanced Access Control Course 3000

Advanced Access Control Course 3000. Elevator Control. Elevator Control Overview. LNL-1320 button interrupt elevator control 1-6 floors LNL-1320 Relays interrupt elevator floor selection button LNL-1300 button interrupt elevator control 1-128 floors Uses LNL-1300 and LNL-1200 combination

kolina
Download Presentation

Advanced Access Control Course 3000

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Advanced Access ControlCourse 3000 Elevator Control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  2. Elevator Control Overview • LNL-1320 button interrupt elevator control • 1-6 floors • LNL-1320 Relays interrupt elevator floor selection button • LNL-1300 button interrupt elevator control • 1-128 floors • Uses LNL-1300 and LNL-1200 combination • LNL-1300 elevator control with floor tracking • 1-128 floors • Uses LNL-1300, LNL-1100 and LNL-1200 combination CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  3. This example shows a button interrupt setup that will allow the cardholder to select floors 1, 2, 4 & 5 but only chooses floor 1. N/C C N/O LNL-1320 Button Interrupt Example To Elevator Control Room ISC LNL-1320 Elevator Floor Button Reader 1 1 2 3 4 1 2 3 4 5 6 5 6 CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  4. LNL-1300 Button Interrupt Example To Elevator Control Room ISC Elevator Floor Button 1 1 2 3 ~8 LNL-1200 4 5 6 1 2 3 4 5 7 8 9 6 7 8 9 10 Reader 10 11 12 11 12 13 14 LNL-1300 13 14 15 15 16 16 This example shows a button interrupt setup that will allow the cardholder to select floors 1, 2, 4, 5, 10, 12, 14 and 15 but only chooses floor 1. CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  5. LNL-1300 Floor Tracking Example ISC To Elevator Control Room Reader LNL-1300 ~8 LNL-1100 ~8 LNL-1200 Elevator Floor Buttons 1 2 3 4 5 6 7 8 9 10 1 1 2 11 12 13 14 3 4 15 16 5 6 CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  6. Elevator Control Access Panels • Elevator Control must be enabled at the ISC for all types of elevator controls • Reserves memory in the ISC • Allows readers to be configured for elevator control • NOTE: Elevator control is not supported on the LNL-2210 CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  7. Elevator Control Access Panels CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  8. Reader Setup • LNL-1320 Elevator Control • Button Interrupt • LNL-1300 Elevator Control • Button Interrupt • Floor Tracking CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  9. LNL-1320 Elevator Control • Lenel LNL-1320 Button Interrupt • Track floors not available • On-board relays used for control • Reader two disabled • Additional elevator hardware not used CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  10. LNL-1320 Elevator Control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  11. Elevator Control Levels and Access Levels • Comparing Access Levels and Elevator Control Levels • Elevator Control Levels • Combination of Timezones, Relay Outputs and Floors • 256 Elevator Control Levels Supported • Elevator Control Levels used to configure: • Elevator Access Level assigned to badge • Day mode for free access to floors • Access Levels • Combination of Readers and Elevator Control Levels • Elevator control level treated as a multi-floor timezone • Standard readers and elevator readers may be combined into the same access level CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  12. Elevator Control Levels CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  13. Elevator Control Levels CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  14. Using Elevator Control • Access Granted Events • Pulses 1320 relays based on assigned Elevator Controls • Pulse duration is set by adjusting each reader’s strike time CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  15. Using Elevator Control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  16. LNL-1300 Button Interrupt • Lenel LNL-1300 Button Interrupt • Check Elevator Control only • Additional elevator hardware must be used • Must be configured through the Reader Elevator Hardware tab • LNL-1200 relays used for control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  17. LNL-1300 Button Interrupt CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  18. Elevator Hardware • Used in conjunction with the LNL-1300 • Assigns up to 8 LNL-1200 Output Control Modules for use in elevator control • Without Floor tracking checked LNL-1200 is the only hardware available • Outputs may be renamed to match floor names • System Administration | Access Control | Alarm Panels | Alarm Outputs CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  19. Elevator Hardware CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  20. LNL-1300 Floor Tracking • Lenel LNL-1300 Floor Tracking • Check Elevator Control and Track Floors • Additional elevator hardware must be used • Must be configured through the Reader Elevator Hardware tab • LNL-1100 inputs used to detect which floor has been requested CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  21. LNL-1300 Floor Tracking CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  22. LNL-1300 Floor Tracking • Used in conjunction with the LNL-1300 • Assigns up to 8 LNL-1100 Input Control Modules for use in elevator control • With Floor Tracking checked LNL-1100 and LNL-1200 are available CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  23. LNL-1300 Floor Tracking CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  24. Custom Day Mode • Pre-defined floors have free access during active day mode timezone • Each floor may use a different time zone • LNL-1320 will have output(s) energized • LNL-1300 requires button selection • Day Mode Elevator Control assigned per reader • Under Access Control | Reader | Control Tab | Elevator Control Settings Area CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  25. Custom Day Mode CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  26. Online Facility Code • Online Facility Code – No Floor Tracking • All outputs defined in the Elevator Control Level (ECL) selected from the drop down box will energize when granted facility code is issued at the reader • Works for LNL-1300 and LNL-1320 elevator solutions • The reader must be on-line and in facility code mode • Online Facility Code – With Floor Tracking enabled for LNL-1300 • Outputs defined in the Elevator Control Level (ECL) selected from the drop down box will be available • Selection of the floor via elevator button is necessary • The reader must be on-line and in facility code mode CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  27. Online Facility Code CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  28. Offline Access • LNL-1320 offline from ISC • Output 1 will energize when a badge (with valid facility code) is presented to the elevator reader • LNL-1300 offline from ISC • No Floor Tracking – all outputs defined in the Elevator Control Level (ECL) selected in the drop down box for Online Facility Code will energize • With Floor Tracking enabled – the outputs defined in the Elevator Control Level (ECL) selected in the drop down box for Online Facility Code will be available • Selection of the floor via elevator button is necessary CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)

  29. Summary • Elevator control • 1320 Button Interrupt • 1300 Button Interrupt • 1300 Floor Tracking • Day Mode • Online Facility Mode • Offline Access CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)