310 likes | 613 Views
Advanced Access Control Course 3000. Elevator Control. Elevator Control Overview. LNL-1320 button interrupt elevator control 1-6 floors LNL-1320 Relays interrupt elevator floor selection button LNL-1300 button interrupt elevator control 1-128 floors Uses LNL-1300 and LNL-1200 combination
E N D
Advanced Access ControlCourse 3000 Elevator Control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Control Overview • LNL-1320 button interrupt elevator control • 1-6 floors • LNL-1320 Relays interrupt elevator floor selection button • LNL-1300 button interrupt elevator control • 1-128 floors • Uses LNL-1300 and LNL-1200 combination • LNL-1300 elevator control with floor tracking • 1-128 floors • Uses LNL-1300, LNL-1100 and LNL-1200 combination CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
This example shows a button interrupt setup that will allow the cardholder to select floors 1, 2, 4 & 5 but only chooses floor 1. N/C C N/O LNL-1320 Button Interrupt Example To Elevator Control Room ISC LNL-1320 Elevator Floor Button Reader 1 1 2 3 4 1 2 3 4 5 6 5 6 CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Button Interrupt Example To Elevator Control Room ISC Elevator Floor Button 1 1 2 3 ~8 LNL-1200 4 5 6 1 2 3 4 5 7 8 9 6 7 8 9 10 Reader 10 11 12 11 12 13 14 LNL-1300 13 14 15 15 16 16 This example shows a button interrupt setup that will allow the cardholder to select floors 1, 2, 4, 5, 10, 12, 14 and 15 but only chooses floor 1. CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Floor Tracking Example ISC To Elevator Control Room Reader LNL-1300 ~8 LNL-1100 ~8 LNL-1200 Elevator Floor Buttons 1 2 3 4 5 6 7 8 9 10 1 1 2 11 12 13 14 3 4 15 16 5 6 CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Control Access Panels • Elevator Control must be enabled at the ISC for all types of elevator controls • Reserves memory in the ISC • Allows readers to be configured for elevator control • NOTE: Elevator control is not supported on the LNL-2210 CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Control Access Panels CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Reader Setup • LNL-1320 Elevator Control • Button Interrupt • LNL-1300 Elevator Control • Button Interrupt • Floor Tracking CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1320 Elevator Control • Lenel LNL-1320 Button Interrupt • Track floors not available • On-board relays used for control • Reader two disabled • Additional elevator hardware not used CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1320 Elevator Control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Control Levels and Access Levels • Comparing Access Levels and Elevator Control Levels • Elevator Control Levels • Combination of Timezones, Relay Outputs and Floors • 256 Elevator Control Levels Supported • Elevator Control Levels used to configure: • Elevator Access Level assigned to badge • Day mode for free access to floors • Access Levels • Combination of Readers and Elevator Control Levels • Elevator control level treated as a multi-floor timezone • Standard readers and elevator readers may be combined into the same access level CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Control Levels CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Control Levels CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Using Elevator Control • Access Granted Events • Pulses 1320 relays based on assigned Elevator Controls • Pulse duration is set by adjusting each reader’s strike time CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Using Elevator Control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Button Interrupt • Lenel LNL-1300 Button Interrupt • Check Elevator Control only • Additional elevator hardware must be used • Must be configured through the Reader Elevator Hardware tab • LNL-1200 relays used for control CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Button Interrupt CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Hardware • Used in conjunction with the LNL-1300 • Assigns up to 8 LNL-1200 Output Control Modules for use in elevator control • Without Floor tracking checked LNL-1200 is the only hardware available • Outputs may be renamed to match floor names • System Administration | Access Control | Alarm Panels | Alarm Outputs CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Elevator Hardware CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Floor Tracking • Lenel LNL-1300 Floor Tracking • Check Elevator Control and Track Floors • Additional elevator hardware must be used • Must be configured through the Reader Elevator Hardware tab • LNL-1100 inputs used to detect which floor has been requested CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Floor Tracking CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Floor Tracking • Used in conjunction with the LNL-1300 • Assigns up to 8 LNL-1100 Input Control Modules for use in elevator control • With Floor Tracking checked LNL-1100 and LNL-1200 are available CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
LNL-1300 Floor Tracking CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Custom Day Mode • Pre-defined floors have free access during active day mode timezone • Each floor may use a different time zone • LNL-1320 will have output(s) energized • LNL-1300 requires button selection • Day Mode Elevator Control assigned per reader • Under Access Control | Reader | Control Tab | Elevator Control Settings Area CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Custom Day Mode CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Online Facility Code • Online Facility Code – No Floor Tracking • All outputs defined in the Elevator Control Level (ECL) selected from the drop down box will energize when granted facility code is issued at the reader • Works for LNL-1300 and LNL-1320 elevator solutions • The reader must be on-line and in facility code mode • Online Facility Code – With Floor Tracking enabled for LNL-1300 • Outputs defined in the Elevator Control Level (ECL) selected from the drop down box will be available • Selection of the floor via elevator button is necessary • The reader must be on-line and in facility code mode CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Online Facility Code CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Offline Access • LNL-1320 offline from ISC • Output 1 will energize when a badge (with valid facility code) is presented to the elevator reader • LNL-1300 offline from ISC • No Floor Tracking – all outputs defined in the Elevator Control Level (ECL) selected in the drop down box for Online Facility Code will energize • With Floor Tracking enabled – the outputs defined in the Elevator Control Level (ECL) selected in the drop down box for Online Facility Code will be available • Selection of the floor via elevator button is necessary CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)
Summary • Elevator control • 1320 Button Interrupt • 1300 Button Interrupt • 1300 Floor Tracking • Day Mode • Online Facility Mode • Offline Access CR3000 - M07.01 - 6.4.500 TU 1 (Elevator Control)