1 / 9

Reference Thermometers

Reference Thermometers. CPT1000 Platinum Resistance. CPT2000 Platinum Resistance. Features & Benefits. CPT9000 Thermocouple. CED7000 & others Signal calibrators. Reference Thermometer. CTP1000. PLATINUM RESISTANCE THERMOMETER Measuring range -100 to 670 o C

kolina
Download Presentation

Reference Thermometers

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Reference Thermometers • CPT1000 • Platinum Resistance • CPT2000 • Platinum Resistance Features & Benefits • CPT9000 • Thermocouple • CED7000 & others • Signal calibrators

  2. Reference Thermometer CTP1000 • PLATINUM RESISTANCE THERMOMETER • Measuring range -100 to 670oC • Stability better than 40mK after 100h at 660oC • Dimensions: Ø 6.35mm, l= 450mm • 4-wire connection, ends stripped and tin-coated Data Sheet CT61.10…

  3. Reference Thermometer CTP2000 • PLATINUM RESISTANCE THERMOMETER • Measuring range -200 to 450oC • Stability better than 50mK after 100h at 450oC • Dimensions: Ø 6.35mm, l= 450mm • 4-wire connection, ends stripped and tin-coated Data Sheet CT61.10…

  4. Reference Thermometer CTP9000 • THERMOCOUPLE • Measuring range: 0 – 1300oC • Thermocouple: Type S; Class 1 • Dimensions: Ø 7mm, l = 1500mm • 450mm cable, ends with 4mm connector Data Sheet CT61.10…

  5. Temperature Reference thermometer Suitable measuring devices: CEP6000 and CEP6100 Calculation of coefficients possible and necessary Calibration at an accredited laboratory

  6. Temperature Hand- Helds portfolio

  7. Signal Calibrator Hand-Helds Portable Multi-Function CalibratorCEP6000 / CEP6100 • Range: • resistance thermometers(13), • thermocouples (13), • resistance, current, voltage, frequency, pressure • Accuracy: • 0.015 % rdg (mA, V) Applications: • CEP6100 with calibration function

  8. Signal Calibrator Hand-Helds Documenting CEP6100 • Store up to 50 different UUT to • CEP6100 • Print certificate on site • Store certificate on PC • Calculates deviation for you

  9. High-precision process calibrator CED7000 • Measuring range 0…100mA, 0…100V, 5…4000Ω, • -210…+1200⁰C (type J), • -200… +800 ⁰C (Pt100) • Accuracy : 0.003% • Measurement and simulation of thermocouples, resistance thermometers, resistance, current, voltage and pressure Data Sheet CT85.51…