1 / 20

PLATE & FRAME HEAT EXCHANGER

PLATE & FRAME HEAT EXCHANGER. By Farhan Ahmad Department of Chemical Engineering, University of Engineering & Technology Lahore. Introduction. The plate heat exchanger (PHE) was first introduced by Dr Richard Seligman in 1923.

Download Presentation

PLATE & FRAME HEAT EXCHANGER

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PLATE & FRAME HEAT EXCHANGER By Farhan Ahmad Department of Chemical Engineering, University of Engineering & Technology Lahore engineering-resource.com

  2. Introduction • The plate heat exchanger (PHE) was first introduced by Dr Richard Seligman in 1923. • It consist of stack of corrugated or embossed metal plates fitted between a frame. engineering-resource.com

  3. engineering-resource.com

  4. Main Parts Carrying bar Frame plate Pressure plate Plate pack Tightening bolts engineering-resource.com

  5. Plates Inlet / outlet Media 2 Inlet / outlet Media 1 Distribution area Fully supported gasket groove Heat transfer area Distribution area Inlet / outlet Media 2 Inlet / outlet Media 1 engineering-resource.com

  6. Flow Patterns • Series flow arrangement • Single-pass looped arrangement: • U-arrangement • Z-arrangement • Multipass with equal passes • Multipass with unequal pass engineering-resource.com

  7. Series flow arrangement • in which a stream is continuous and changes direction after each vertical path, that is, n pass-n pass with individual passes per channel engineering-resource.com

  8. engineering-resource.com

  9. engineering-resource.com

  10. 2. Single-pass looped arrangement: U-arrangementZ-arrangement • Both fluids flow countercurrently through parallel passages that make up a single pass. engineering-resource.com

  11. Channel plates End Plate II End Plate I PHE - Example Single Pass Hot out Cold in Cold out Hot in engineering-resource.com

  12. Multipass with equal passes • Multipass with equal passes (series flow pattern), wherein the stream divides into a number of parallel flow channels and then recombines to flow through the exit in a single stream, that is, n pass-n pass. engineering-resource.com

  13. PHE – Example Multipass Pass/Channel: Hot Side 2 x 4 Cold Side 2 x 4 Cold out Cold in Hot in Hot out engineering-resource.com

  14. 4. Multipass with unequal pass • 2 pass-1 pass, • 3 pass-1 pass, engineering-resource.com

  15. Design of PHE • LMTD Method • ε- NTU Method engineering-resource.com

  16. LMTD Method • For both looped and series flow arrangements. • The steps involved in the method are given next. For series flow : 1 . Calculate the heat duty. Determine the inlet and outlet temperatures for both the fluids. 2. Estimate LMTD for counterflow arrangement. 3. Estimate Reynolds number for the each stream, assuming an exchanger containing one thermal plate, one pass for each stream, as given: where n is the number of substreams. For series flow, n = 1. 4. Estimate heat-transfer coefficient on both sides 5. Estimate overall heat-transfer coefficient taking into account the wall thermal resistance. 6. Estimate the total heat-transfer area from A = q/U LMTD. 7. Estimate the number of plates from, N=A/Ap where Ap is the area of a plate engineering-resource.com

  17. LMTD Method For parallel flow or looped flow : 1-7. Repeat steps 1 to 7 already given. 8. From the number of thermal plates calculated in step 7, n, is determined for both the fluids. • For odd N, values of n, will be equal for both fluids, • whereas for even N, n, will be different for both the fluids, and one fluid will have an additional substream compared to the other. 9. The values of n, determined in step 8 are compared with the corresponding values assumed in step 3. If the calculated values do not agree with the assumed values, steps 3-9 are to be repeated, replacing the assumed values with the values calculated from step 8 until there is agreement between the two. engineering-resource.com

  18. ε- NTU Method 1. Calculate the heat load, q, and from it determine the inlet and outlet temperatures for both the fluids. 2. Calculate the bulk mean temperature and determine the thermo physical fluid properties. Estimate the heat capacity rate ratio, C*. 3. Estimate the heat-transfer effectiveness, E, using the relation 4. Assume an exchanger containing an infinite number of channels and find the required NTU using the appropriate E-NTU relation. 5 . Estimate Reynolds number for the each stream, assuming an exchanger containing one thermal plate, and one pass for each stream. 6. Calculate the heat-transfer coefficient on both sides. Estimate the overall heat-transfer coefficient, taking into account the wall thermal resistance. engineering-resource.com

  19. ε- NTU Method For series flow : 7. Estimate the approximate number of thermal plates using the equation where Δtm is the mean temperature difference. 8. Assuming an exchanger of N + 1 channels, determine NTU from the appropriate E-NTU relationship. 9. Recalculate N from Eq. 18. 10. Repeat calculations in steps 8 and 9 until the calculated value of N in step 9 matches the assumed value in step 8. engineering-resource.com

  20. ε- NTU Method For parallel flow or looped flow • In a design involving looped flow patterns, the overall coefficient requires recalculation during each iteration because the channel flow rates become less with the addition of channels in parallel. The calculation procedure for looped flow is as follows: 7. Assuming an exchanger of N thermal plates, calculate the overall heat-transfer coefficient as in step 6. 8. Estimate the approximate number of thermal plates using Eq. 18. 9. Assuming an exchanger of N + 1 channels, determine NTU from the appropriate E-NTU relationship for looped flow. 10. Recalculate the overall heat-transfer coefficient as per step 6 and recalculate N with Eq. 11. Repeat calculations in steps 9 and 10 until the calculated value of N matches with the assumed value. engineering-resource.com

More Related