AMA-61850-FiT4HANA Designed for Big Data. Cooperation between AMA-SYSTEMS, Fichtner IT and SAP. Content. AMA-Systems GmbH The IEC 61850 Standard AMA-61850-FiT4HANA. AMA-SYSTEMS GMBH.
E N D
AMA-61850-FiT4HANADesignedfor Big Data Cooperation between AMA-SYSTEMS, Fichtner IT and SAP
Content • AMA-Systems GmbH • The IEC 61850 Standard • AMA-61850-FiT4HANA
AMA-SYSTEMS GMBH • AMA-SYSTEMS founded in 1976 in Germany as an Engineering Company and is focused on the Automation – Information – Communication area. • AMA-SYSTEMS offers high quality standard HW and SW Products and also Engineering for the Optimization of ENERGY & UTILITY in Europe. • AMA is called “The Standard Based Integration Specialist” for IEC 61850 and IEC 60870-6/ICCP/TASE.2. • AMA is • Value added Reseller (VAR)of SISCO Inc. (US) for Europe. • Partner of OSIsoft, IBM and SAP.
FICHTNER GROUP • Established in 1922, the Fichtner Group is today Germany’s biggest independent engineering and consultancy enterprise • Approximately 2,000 employees worldwide – 500 in Stuttgart Home Office • Total turnover of €260 million in 2012 • Capital investment volume now under planning in the home office: €106 billion – of which some €26 billion is in renewable energies • FICHTNER IT CONSULTING • Competence Center for IT Consultancy and Solutions • Project focus on GIS and portal solutions, system integration, maintenance, asset management and billing • Strong SAP competence through our subsidiaries P&S Consulting GmbH and SPE Unternehmensberatung GmbH (Validated Expertise for Utilities) Source:Fichtner
AMA-SYSTEMS Products • Gateways • AMA-ICCP-TCP-GW-1L. • Server Simulator for IEC 61850 • AMA-61850-ServerSim-G • Test Procedures for Conformance Testing • AMA-61850-Test-KiT • IEC 61850 Client Interface for Big Data • AMA-61850-FiT4HANA • Trainings, Workshops, Technical Support forIEC 61850 andICCP
IEC 61850 Standard IEC 61850 Client Server Architecture IEC 61850 is an Interoperability Standard for Communicationbetween IEDs and Software Systems: Hardware independent, bidirectional, Ethernet TCP/IP based. IEC 61850 Server IEC 61850 Server IEC 61850 Server IEC 61850 Server IEC 61850 Layer Model Information Model ( IED Description ) Configuration Language Communication Network ( Ethernet, TCP/IP ) Information Exchange ( get, set, log, …) Communication Profiles ( Ethernet, TCP/IP) Source: Fichtner; AMA-SYSTEMS IEC 61850 Client Messages
Benefits in Substations and Bays • Using IEC 61850 standard in System Control createsverysignificantbenefits: • Above all reducing TCO. • Shorter time ofImplementation. • Independence fromHardware andSoftware Suppliers. Source:SISCO
IEC 61850 based Integration IEC 61850 based Integration will also play a majorrole in thefuturefordecentralizedEnergy Systems such as Smart Grid Environments or Smart Meters. Decentralized PV Generation Decentralized Wind Generation IEC 61850-7-420 Hydropower Plant IEC 62445-2(IEC 61850-90-2) IEC 62445-2(IEC 61850-90-2) IEC 62445-2(IEC 61850-90-2) IEC 61400-25 IEC 61850-7-410 Centralized Generation Grid Control Center ICCP/TASE.2/IEC 60870-6 Stations IEC 61850-90-1 IEC 61850 IEC 61850
Benefits from Interoperability • Fewer outages, due to better system monitoring, analysis and management. • Faster service restoration following an outage. • Better information flow leads to higher system resistance against attacks. • Better resource adequacy because interoperability enables better integration of diverse supply.
IEC 61850 and Smart Grid Applications Architecture View:IEC 61850 Series Standardsin many Roles within the Smart Grid. Source: IEC: http://smartgridstandardsmap.com/
HANA/SAP – a “Big Data”Realtime Data Platform The implementationof IEC 61850 as a genericmodulein SAP HANA is a basiccomponentofthenew Fichtner Energy Software Suite on HANA Fichtner solution Time Series Management Source:SAP, Fichtner
IEC 61850 Standard for Big Data IEC 61850 module as third party component of SAP HANA time series • data platform The AMA-SYSTEMS implementationof IEC 61850 as a genericmodulein SAP HANA is a basiccomponentofthenew Fichtner Energy Software Suite on SAP HANA. AMA-SYSTEMS IEC 61850 Module Source:SAP, Fichtner, AMA
SAPHANA IEC 61850 Interface Providesdirectaccesstodataof IEC 61850 Server devices (IEDs) withouttheneedfor an additional Gateway protocol like OPC, ... AMA-SYSTEMS IEC 61850 Client Interface DirectaccesstoIEC 61850 avoidsthedisadvantagesof such Gateway protocols as additional mappingeffort, riskofmapping errors, communication bottle-neck, ... • ReportsData Change, Periodic • Read Response • Read Request • Ethernet, TCP/IP • otherIEC 61850 Devices
Big Data Analytics of IEC 61850 Standard The AMA-SYSTEMS IEC 61850 Module in HANA/SAP will enablevery fast Sensor Data inputintotheTime Series and RDP platformandthe subsequent use in value- addedApplications. Fichtner BGI Analytics Analysis, Visualization, Editing SAP HANA Realtime Data Platform SCADA Data Inspection Data Wind KPI calculationandcomparison FailureHistory Lightning Time Series Analysis Asset Master Data SatelliteData Time Series Core Services Financial Data AMA-SYSTEMS IEC 61850 Client Maintenance Analysis , drill down tosensordataandworkorders IEC 61850 Server SAP Backend PS Non SAP Systems Web Services FMEA Analysis ConditionMonitorimg Failuredata Source: Fichtner IT EAM FI/CO Other Constructiondata