1 / 12

NPDG Liquid Hydrogen Target: Design and Safety Features

NPDG Liquid Hydrogen Target: Design and Safety Features. Target vessel Main vacuum Vent isolation chamber He and Ar gas. M. Snow, Indiana. Design goals. Hydrogen SAFETY - target has to be absolutely safe to operate - it has to be in compliance with codes.

lacy-wiley
Download Presentation

NPDG Liquid Hydrogen Target: Design and Safety Features

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NPDG Liquid Hydrogen Target: Design and Safety Features • Target vessel • Main vacuum • Vent isolation chamber • He and Ar gas M. Snow, Indiana

  2. Design goals • Hydrogen SAFETY - target has to be absolutely safe to operate - it has to be in compliance with codes. • Target must absorb as much polarized cold neutrons as possible.  Target size of 30cm dia and 30cm length absorbs 60% cold n’s. • To prevent neutron depolarization, requires para-hydrogen at T17 K  0.05% of LH2 is in ortho state  1% of neutrons depolarized. • Suppress bubbles+safety  P>1 atm • Negligible attenuation forg’s requires low Z (Al, Li plastic) • 6Li-rich neutron shield • Cryostat must be non-magnetic.

  3. Main Guidance from Safety Reviews No release of hydrogen into the experimental cave from failure of the main vacuum system or target vessel. Large volume of LH2 (~20 liquid liters)+location->vent system rather than thermosyphon Application of the concept of “triple containment” to the LH2 in the cave (target vessel, vacuum, helium) Capability to rapidly and safely vent LH2 on command in emergency situations (fire, etc.)

  4. Cryostat and Vent System

  5. LH2 target vessel Welded 6061-T6 Al pressure vessel Shape from FEA analysis Conflat seals Room temp P tests to 90 psid 1.5” ID outlet 2 weld seams, no windows

  6. Box+cylinder+access plate. Box machined from single Al ingot, reduce welds Windows: double-walled Al with stiffening rings Helium gas between windows, around all weld joints and o-ring seals using internal channel design Vacuum+windows tested to 70 psid Main vacuum chamber

  7. Other Safety Features • No wiring into LH2 part of cryostat • Thick walls: no accidental punctures • Two refrigerators: still a cryopump if one fails (GHS pumps valved off) Target Vessel Main vacuum box with stand

  8. Pressures: operating points, MAWPs, set points

  9. Cryostat and gas handling system in the shed He & Ar Supply manifold Cryostat RGA Vacuum H2 GHS PANEL

  10. Allows the relief valves and burst disks to be contained in a clean He atmosphere Chamber OK for internal pressure allows for easy access for adjustment/ replacement Vent Isolation Chamber

  11. Helium for vent line, backing of rupture disks and vent valves,triple containment of LH2 chamber Inert Bleedback into target From o-ring diffusion, Burps of blowoff valves do not introduce ignition source to LH2

  12. Argon supply to poison main vacuum for controlled target venting Inert Phase transition helps deliver heat to outside of vessel quickly Recommended as safer than electrical heater around target