1 / 15

A Universal Free-Standing Accessory to Improve ICP Productivity

A Universal Free-Standing Accessory to Improve ICP Productivity. Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd., Pocasset, MA 02559, jdulude@geicp.com . Integration. AS to sample. Rinse. AS to rinse. Smpl fills line. Plasma equil. Smpl empties line. 7. 5. 3. 1.

lala
Download Presentation

A Universal Free-Standing Accessory to Improve ICP Productivity

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A Universal Free-Standing Accessory to Improve ICP Productivity Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd., Pocasset, MA 02559, jdulude@geicp.com

  2. Integration AS to sample Rinse AS to rinse Smpl fills line Plasma equil Smpl empties line 7 5 3 1 Sample Cycle for Unattended ICP Analysis 6 4 2 Glass Expansion www.geicp.com

  3. Benefits of Decreasing the Analytical Cycle • More samples/hour • Faster sample turn-around time • Delay procurement of additional instruments • Reduce consumables cost/sample • Argon • Torches • Nebulizers • Cones Glass Expansion www.geicp.com

  4. Methods to Reduce Analysis Cycle(without degrading performance) • Minimize dead volume • Software approaches • Valve switching Glass Expansion www.geicp.com

  5. Removing Dead Volume • Nebulizer – EzyFit • Spray chamber – Helix • Internal Standard – Low volume chamber Glass Expansion www.geicp.com

  6. Software Approaches to Speeding Analysis • Fast pump in rinse mode • longer equilibration • Predictive Rinse • QC’s complicated • Risk of carryover • Intelligent Rinse • Rinse is based on sample results • Analyzes rinse to determine optimum time • Modest productivity gain Glass Expansion www.geicp.com

  7. Niagara™ Rapid Rinse Accessory • Interfaces between ICP & Autosampler • Reduces required rinse time • Programmable delay time • Less than 8 inches high • Includes adj. height stand Glass Expansion www.geicp.com

  8. How Niagara Works Rinse Analysis Glass Expansion www.geicp.com

  9. ICP-OES or ICP-MS PC Autosampler Niagara Interface – no software required • Started with hardware trigger on AS • Recently modified to serial interface • Serial cable runs from ICP computer through the AS to the Niagara. • Each Niagara is preprogrammed for a specific ICP/AS combination. Niagara Glass Expansion www.geicp.com

  10. Niagara Time Saving Elan 6000 ICP-MS, Hill Labs, New Zealand 30 second rinse 10 second rinse = Rinse steps for nebulizer & spray chamber Glass Expansion www.geicp.com

  11. ICP-MS Carryover Comparison Standard method without Niagara With Niagara Glass Expansion www.geicp.com

  12. Zinc Boron Moly Thallium ICP-MS Carryover Comparison Glass Expansion www.geicp.com

  13. On-Line Productivity Calculatorwww.geicp.com Glass Expansion www.geicp.com

  14. Payback with Niagara-CommercialLab Glass Expansion www.geicp.com

  15. Summary • Decrease dead-volume in sample introduction system to reduce rinse time • Software approaches produce marginal productivity improvements • Niagara produces clear gains in productivity without jeopardizing performance. Glass Expansion www.geicp.com