1 / 14

Reference Block

July 25, ’03 KEK H. Yamaoka. Reference Block. Al. SUS. Isolator. No. Spring Constant (N/mm). Allowable Load (N). Z. Y. X. Z. Y. X. EC4001. 125. 98. 37. 490. 290. 195. EC4002. 235. 180. 69. 1250. 735. 490. EC4003. 340. 235. 93. 1850. 980. 635. EC4004. 490. 325.

lance
Download Presentation

Reference Block

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. July 25, ’03 KEK H. Yamaoka Reference Block

  2. Al SUS

  3. Isolator

  4. No. Spring Constant (N/mm) Allowable Load (N) Z Y X Z Y X EC4001 125 98 37 490 290 195 EC4002 235 180 69 1250 735 490 EC4003 340 235 93 1850 980 635 EC4004 490 325 115 2900 1450 830 EC4005 585 400 160 4100 2050 1400

  5. = acoswt TR: Transmissibility, TR < 0.1 A : Amplitude(Response) a : Amplitude(Input)

  6. ANSYS Calculation Z Fixed!! X Y

  7. k= 98N/mm k= 37N/mm Isolators Z k= 125N/mm X Y

  8. 1st: 62Hz 4th: 263Hz 2nd: 69Hz 5th: 461Hz 3rd: 103Hz 6th: 481Hz

  9. 1st: 4.8Hz 13th: 203Hz 2nd: 5.5Hz 15th: 341Hz 3rd: 13Hz 16th: 403Hz

  10. Spectrum Analysis Input: (X, Y, Z- directions)

  11. Results(Absolute value) X-Direction C R L Z Fixed Y X Y-Direction Z-Direction

  12. C R L X-Direction k= 98N/mm k= 37N/mm Z k= 125N/mm Y X Fixed Y-Direction Z-Direction

  13. Integration Amplitude X-Direction C R L Z Fixed Y X Z-Direction Y-Direction

  14. C R L X-Direction k= 98N/mm k= 37N/mm Z k= 125N/mm Y X Fixed Y-Direction Z-Direction