1 / 10

Setups ( BELEN , MONSTER  D. Cano-Ott/ CIEMAT )

Theme group for b -delayed neutron measurements. Setups ( BELEN , MONSTER  D. Cano-Ott/ CIEMAT ) Implantation detector ( SIMBA , AIDA (>autumn 2010) ) Beams N=50 (78Ni): 124Sn (?) N=82 (132Sn, 130Cd): 136Xe, 238U, others (150Nd,154Sm?) N=126: 238U, 208Pb, (197Au)

laurie
Download Presentation

Setups ( BELEN , MONSTER  D. Cano-Ott/ CIEMAT )

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Theme group for b-delayed neutronmeasurements • Setups (BELEN, MONSTER  D. Cano-Ott/ CIEMAT) • Implantation detector (SIMBA, AIDA (>autumn 2010)) • BeamsN=50 (78Ni): 124Sn (?) N=82 (132Sn, 130Cd): 136Xe, 238U, others (150Nd,154Sm?) N=126: 238U, 208Pb, (197Au) • Timeline for tests and experiments

  2. (Near) Timeline • Summer 2010: Neutron background test at S4 (5 single BELEN detectors): Implementation of BELEN and SIMBA into the GSI DAQ • Spring 2011?: Setup and test of BELEN-30 at GSI, first parasitic in-beam tests, then min. 2 weeks break (no exp. @ S4) • Early summer 2011?: Beamtime (6 days S323, 7 days S410) • >end of 2011- mid 2013: AGATA is coming, no BELEN measurements possible! Move BELEN to other labs • 2016(?): during construction of Super-FRS: experiments possible

  3. t1/2 exists identified GSI proposal Pn (%) QRPA N=82: Approved experiment (S323) N=82

  4. t1/2 exists identified GSI proposal Pn (%) QRPA N=126: Approved experiment (S410) N=126

  5. 30 counters 20 counters DETECTION EFFICIENCY [%] NEUTRON ENERGY [MeV] BEta deLayEd Neutron detector (BELEN) Efficiency for setup at GSI 2011 New BELEN-30 for GSI

  6. Silicon IMplantation detector and Beta Absorber (SIMBA) Constructed and developed at TU München Pictures: K. Steiger • • 1 x and 1 y-detector, 60x60x0.3 mm3, 60fold segmented each • 2 SSSSD, 60x40x1 mm3, 7fold segmented in x • 3 DSSSD (implantation area), 60x40x0.7 mm3, 60fold segmented in x-, 40fold in y-direction • 2 SSSSD, 60x40x1 mm3, 7fold segmented in x PhD thesis C. Hinke, TUM (2010) Diploma thesis K. Steiger, TUM (2009) to be replaced by AIDA in >2012

  7. Future • Similar proposals @ other labs? • Upgrades of the setup (more 3He counters, +g-det., AIDA...) • New proposals • Evaluation/ compilation of bdn • Workshop? (astrophysicists, reactor physicists, ...) • BELEN detector can/will be moved to other labs for experiments • Jyväskyla • ?GANIL? Possible future proposals: 78Ni (N=50, Z=28) 134In, ... (b2n emitters, check GANIL, ALTO program) 194W, 192Hf (deformed, Pn~10% predicted)

  8. (Main) institutions • UPC Barcelona • IFIC Valencia • CIEMAT Madrid • Santiago de Compostela • Jyväskyla • JINR Dubna • GSI-Giessen • Surrey • ...

  9. Setup: BELEN for DESPEC • 44 3He counters arranged in 3 crowns ~65% efficiency • 90cm90cm70cm PE block • 16cm hole for AIDA implantation detector • Triggerless DACQ: independent (t,E) for every counter, no ADC gate, minimum dead time, freedom to construct time correlations

  10. BEta deLayEd Neutron detector (BELEN) BELEN-20 Collaboration Universidad Politecnica de Cataluna, Barcelona IFIC Valencia CIEMAT Madrid BELEN-30 Collaboration: additionally