150 likes | 174 Views
Thermal Compensation Review. David Ottaway LIGO Laboratory MIT. Overview. Overview of Problem Road map for design choices (Set by other systems) Summary of current results from subscale tests and modeling Current known unresolved issues Conclusions. Thermal Distortion.
E N D
Thermal Compensation Review David Ottaway LIGO Laboratory MIT
Overview • Overview of Problem • Road map for design choices (Set by other systems) • Summary of current results from subscale tests and modeling • Current known unresolved issues • Conclusions LIGO Laboratory
Thermal Distortion • Absorption in coatings and substrates => Temperature Gradients • Temperature Gradients => Optical path distortions • 3 Types of distortions, relative strengths of which are shown below: LIGO Laboratory
Thermal Comparison of Advanced LIGO to LIGO 1 LIGO Laboratory
Effect on Advanced LIGO Interferometers LIGO Laboratory
Adaptive Thermal Compensation • Compensate for distortions in the substrates • Essential for Advanced LIGO sensitivity to be realized • Two parts to thermal compensation: 1. Coarse compensation of thermal lensing using heating ring and shielding 2. Small scale compensation using scanning CO2 laser • Accurate measurement of sapphire and fused silica thermal mechanical properties enable accurate models • Good propagation models to set design requirements (Melody and FFT Code) LIGO Laboratory
Requirements that flow from other systems • Core Optics (Down select) Sapphire -Significant possible inhomogeneous absorption -> Small spatial scale correction (scanning laser) -Large thermal conductivity -> Small amount of coarse compensation (ring heater) on compensation plates Fused Silica -Poor thermal conductivity and homogenous absorption (ring heater) • DC or RF read out scheme (Down select) -Reduces dependence on sidebands, might affect design requirements • Wavefront Sensing (LIGO 1 experience, not fully understood) -High spatial quality sidebands are probably necessary for accurate alignment control, may negate the effect of read out scheme LIGO Laboratory
Summary of Subscale Experiments and Modeling • Accurate measurements of fused silica and sapphire material properties • Experimental demonstration of shielded heater ring coarse spatial correction • Experimental demonstration of scanning CO2 laser fine spatial scale correction • Accurate models of Advanced LIGO Interferometers style interferometer using Melody and finite element analysis (Femlab), (Thermal modeling without SRM) • Scaling from subscale to full scale understood • Work done by Ryan Lawrence LIGO Laboratory
Thermophysical Parameters Measurement (295-320 K) LIGO Laboratory
Heater Ring Thermal Compensation LIGO Laboratory
Sub Scale Scanning Laser Test LIGO Laboratory
Scanning Laser Test Result Uncorrected Optic (6712 ppm scatter from TEM00) Corrected Optic (789 ppm scattered from TEM00) LIGO Laboratory
Predicted Effected of Thermal Compensation on Advanced LIGO LIGO Laboratory
Current Unresolved Issues • Gravitational wave sideband distortion and its effect on sensitivity. Generated within the cavity no distortion nulling due to prompt reflection. Greater understanding through incorporation in Melody (Ray Beausoleil) • Fabry-Perot mode size change due to input test mass surface deformation => Spot size change (actuate on arm cavity faces) • Accurate 2D absorption maps of Sapphire to aid in actuator selection (negative or positive dN/dT actuator plates) LIGO Laboratory
Conclusions • Subscale proof of principal experiment have been completed • Two different methods of compensation explored • Good agreement between theory and experiment • Reliable cavity modelling code (Melody) will allow accurate setting of final design requirements • Final design requirements require decisions from other sub-systems but should be achievable, regardless of these decisions LIGO Laboratory